1. Introduction
The Astral Micro RX Digital Dosing Pump is an essential accessory for automatic Redox regulation in your swimming pool. This digital peristaltic pump features an integrated Redox instrument and operates with a proportional mode from 0% to 100%. It is designed for easy and quick installation, ensuring optimal water quality in your pool.
2. Safety Information
Please read all safety instructions carefully before installation and operation. Failure to do so may result in injury or damage to the product.
- Always disconnect the power supply before performing any maintenance or installation.
- Ensure the product is installed by a qualified professional if you are unsure.
- Do not operate the pump if it is damaged.
- Keep out of reach of children.
- The unit is rated IP65 for protection against dust and water jets, but it should not be submerged.
- Use only the specified chemicals and solutions with the pump.
3. Package Contents
Verify that all components are present in the package:

Image: Astral Micro RX Dosing Pump and its complete installation kit, showing the pump unit, tubes, probe, and other accessories.
- Complete kit including electronic regulation with a dosing pump.
- Take-off collars.
- Injection valve with non-return and probe holder.
- Product suction filter.
- Wall mounting bracket.
- Suction and product return tubes (2m suction tube, 1 year tube).
- Buffer solution.
- Redox probe.

Image: Front view of the Astral Micro RX Digital Dosing Pump, showing the peristaltic pump mechanism on the left and the digital display and control buttons on the right.

Image: The retail packaging box for the Astral Micro RX Digital Dosing Pump, featuring product imagery and branding.
4. Setup
Follow these steps for proper installation:
- Mounting: Securely mount the pump unit to a wall using the provided wall mounting bracket (5). Ensure it is in a dry, protected area, away from direct sunlight and extreme temperatures.
- Probe Installation: Install the Redox probe (9) into the probe holder (3). Connect the probe holder to your pool's circulation system.
- Tubing Connection:
- Connect the suction tube (6) from the product container (e.g., chlorine solution) to the pump's inlet. Ensure the product suction filter (4) is at the end of the tube inside the container.
- Connect the product return tube (7) from the pump's outlet to the injection valve (3) in your pool's return line.
- Power Connection: Connect the pump to a 230V 50/60Hz power supply. Ensure the power outlet is protected by a residual current device (RCD).
- Initial Calibration: Perform a semi-automatic calibration of the probe using the provided buffer solution (8). Refer to the on-screen instructions on the pump's digital display.
5. Operating Instructions
The Astral Micro RX pump automatically controls the Redox level of your pool water.
- Power On: Once connected to power, the pump will display the current Redox reading.
- Setting the Target Redox: Use the "CAL" and "SET" buttons on the control panel to adjust the desired Redox set point. Consult your pool chemical guidelines for the recommended Redox levels.
- Proportional Dosing: The pump will automatically dose the chemical (e.g., chlorine) proportionally to maintain the set Redox level. The dosing rate adjusts based on the difference between the current and target Redox values.
- Monitoring: Regularly check the digital display for the current Redox reading and ensure the chemical container is not empty.
6. Maintenance
Regular maintenance ensures optimal performance and longevity of your dosing pump.
- Probe Cleaning: Clean the Redox probe regularly (e.g., monthly) to remove any buildup that may affect its accuracy. Use a soft cloth and a mild cleaning solution specifically designed for probes.
- Probe Calibration: Recalibrate the probe periodically (e.g., every 3-6 months or as needed) using the buffer solution to ensure accurate readings.
- Peristaltic Tube Replacement: The santoprene peristaltic tube (4x6mm) is a wear part and should be inspected annually for signs of wear or damage. Replace it if necessary to prevent leaks and ensure proper dosing.
- Chemical Container Check: Ensure the chemical container is always adequately filled to prevent the pump from running dry.
- System Inspection: Periodically inspect all tubing, connections, and the injection valve for leaks or blockages.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump not dosing |
|
|
| Inaccurate Redox readings |
|
|
| Leaking from pump/tubing |
|
|
8. Specifications
- Model: Astral Micro RX Digital Dosing Pump
- Model Number: S09AA0116818
- Power Supply: 230V 50/60Hz
- Capacity: 2.4 liters per hour (at 1 bar, 40 rpm)
- Tube Material: Santoprene (4 x 6 mm)
- Protection Rating: IP65
- Maximum Pool Volume: Up to 100 m³
- Control: Integrated Redox instrument, proportional operation (0% to 100%)
- Calibration: Semi-automatic probe calibration
9. Warranty and Support
This product comes with a 2-year warranty from the date of purchase. The warranty covers manufacturing defects and material faults under normal use conditions.
The warranty does not cover:
- Damage caused by improper installation, misuse, or neglect.
- Wear and tear parts such as the peristaltic tube and Redox probe.
- Damage due to external factors like power surges, accidents, or natural disasters.