Munters FCA 26W

Munters Corporation FCA 26W Portable Accessory Tank User Manual

Model: FCA 26W

Product Overview

The Munters Corporation FCA 26W Portable Accessory Tank is designed to automatically supply water to your cooler, ensuring continuous operation. It features a robust design with heavy-duty wheels and a handle for easy portability, and includes an alarm to indicate low water levels. This tank operates without refrigerants or compressors, utilizing evaporative cooling principles.

Munters FCA 26W Portable Accessory Tank

Figure 1: Munters FCA 26W Portable Accessory Tank. This image shows the grey rectangular tank with a handle on one side, a control box with a green switch and a flexible hose on top, and four red wheels at the bottom.

Key Features

Setup

  1. Unpacking: Carefully remove the accessory tank from its packaging. Inspect for any signs of damage during transit.
  2. Placement: Position the tank on a flat, stable surface near the cooler it will supply. Ensure there is adequate space for access and maintenance.
  3. Wheel Assembly (if required): If wheels are not pre-attached, secure the 6-inch wheels to the designated points on the tank's base using the provided hardware.
  4. Connecting to Cooler: Connect the flexible hose from the accessory tank's pump outlet to the water inlet of your compatible cooler. Ensure a secure, leak-free connection.
  5. Filling the Tank: Open the tank lid and fill the tank with clean water. Do not overfill; leave some space at the top to prevent spills.
  6. Power Connection: Plug the tank's power cord into a suitable electrical outlet. Ensure the power switch on the control box is in the OFF position before plugging in.

Operating Instructions

  1. Power On: Once setup is complete, switch the power button on the control box to the ON position. The pump will activate as needed to supply water to the connected cooler.
  2. Automatic Water Supply: The tank is designed to automatically sense the water level in the connected cooler and pump water as required to maintain optimal operation.
  3. Low Water Alarm: An audible alarm will sound if the water level in the accessory tank becomes critically low. This indicates that the tank needs refilling.
  4. Refilling: When the low water alarm sounds, switch the power OFF, open the tank lid, and refill with clean water. Close the lid securely and switch the power ON again.
  5. Portability: Use the heavy-duty handle and wheels to easily move the tank when empty or partially filled. Avoid moving when completely full to prevent spills and strain.

Maintenance

Troubleshooting

ProblemPossible CauseSolution
Tank not pumping water.
  • Power switch is OFF.
  • Tank is empty.
  • Hose is kinked or blocked.
  • Power cord is disconnected.
  • Turn power switch ON.
  • Refill the tank with water.
  • Check and clear the hose.
  • Ensure power cord is securely plugged in.
Low water alarm sounds continuously.
  • Tank water level is low.
  • Sensor malfunction.
  • Refill the tank.
  • Contact customer support if alarm persists after refilling.
Water leakage.
  • Loose hose connection.
  • Damaged hose or tank.
  • Tighten hose connections.
  • Inspect for damage; contact support if severe.

Specifications

Warranty Information

This Munters Corporation FCA 26W Portable Accessory Tank comes with a 1 Year Warranty from the date of purchase. This warranty covers manufacturing defects and workmanship under normal use. Please retain your proof of purchase for warranty claims. For detailed terms and conditions, refer to the warranty card included with your product or contact Munters customer support.

Customer Support

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact Munters Corporation customer support. Refer to the contact information provided on the product packaging or the official Munters website.

Related Documents - FCA 26W

Preview WM54DK Fiberglass Wall Mount Fan with Damper Door and Munters Drive - Instruction Manual
Comprehensive instruction manual for the Munters WM54DK Fiberglass Wall Mount Fan, covering installation, electrical wiring, operation, maintenance, troubleshooting, and winterizing. Includes parts list, dimensions, and diagrams.
Preview Munters MD2 G2 Motor & Controller Replacement Kit Installation Manual for ATS74 and CX74 Fans
This manual provides detailed instructions for installing the Munters MD2 G2 Motor & Controller Replacement Kit for ATS74 and CX74 fans. It includes unpacking, step-by-step installation procedures for both fan types, electrical wiring diagrams for GA500 and V1000 drives, and a troubleshooting guide.
Preview Munters Drive G2 Rotor Replacement Kit Installation Manual
This manual provides detailed instructions for installing the Munters Drive G2 Rotor Replacement Kit for ATS74 and CX74 Fans. It covers unpacking, parts list, and step-by-step installation procedures for both fan models.
Preview Munters AX51 with G2 Munters Drive Instruction Manual
This instruction manual provides detailed information on the installation, operation, and maintenance of the Munters AX51 Air Circulation Fan with G2 Munters Drive. It covers electrical wiring, troubleshooting, and winterizing procedures for optimal performance and longevity.
Preview Manuel d'utilisation Munters IceDry 800/1400
Ce manuel d'utilisation détaillé présente le Munters IceDry 800/1400, un déshumidificateur à dessicant conçu pour offrir une performance de déshumidification efficace dans les chambres froides. Il couvre l'installation, le fonctionnement, la maintenance et le dépannage.
Preview Munters ATLAS 74 Exhaust Fan Installation and Maintenance Manual
Comprehensive guide for installing, operating, and maintaining the Munters ATLAS 74 Exhaust Fan with Munters Drive. Includes detailed instructions, wiring diagrams, troubleshooting, and parts lists.