1. Product Overview

The Aiphone LEF-10S is an Open Voice Selective Call Master Intercom designed for surface mounting. It facilitates audio communication with visitors at a door and with other rooms within a building. This master intercom supports connection with up to 10 Aiphone LAF and LEF Series master intercoms, and LA, LE, or LS Series door and sub-master intercoms.

Key features include an All-Call button for broadcasting messages and a Door Release button for remote access control.

Aiphone LEF-10S Master Intercom unit

Image of the Aiphone LEF-10S Open Voice Selective Call Master Intercom, showing its front panel with buttons and speaker.

1.1 What's in the Box?

2. Safety Information

Please read and understand all instructions before installation and operation. Failure to follow these instructions may result in electric shock, fire, or damage to the product.

3. Installation

The LEF-10S master intercom is designed for surface mounting.

3.1 Mounting

  1. Select a suitable location for the master intercom, ensuring it is easily accessible and within reach of necessary wiring.
  2. Use the provided mounting hardware to securely attach the intercom unit to a desktop or wall surface.

3.2 Wiring

The system requires hardwiring and is powered by a 12V power supply (e.g., Aiphone PS-1225UL, sold separately).

4. Setup

4.1 Initial Power-Up

Once all wiring is complete and secure, connect the 12V power supply to an electrical outlet. The intercom system will power on.

4.2 Volume Adjustment

The chime and audio volume can be adjusted using the dedicated controls on the master intercom unit. Adjust to a comfortable listening level.

5. Operation

5.1 Making a Call

  1. Press one of the 10 selectable buttons corresponding to the desired door or sub-master intercom. An LED indicator will illuminate.
  2. Press and hold the Push-to-Talk button to speak.
  3. Release the Push-to-Talk button to listen for a response.

5.2 Receiving a Call

When a call is received from a sub-master intercom, a momentary chime will sound, and the corresponding LED indicator above the selectable button will illuminate for 20 seconds.

  1. Press the illuminated button to establish communication.
  2. Press and hold the Push-to-Talk button to speak, and release to listen.

5.3 All-Call Function

If an Aiphone BG-10C adapter is connected, the All-Call button allows you to broadcast a message to every intercom connected to the system.

  1. Press the All-Call button.
  2. Press and hold the Push-to-Talk button to broadcast your message.
  3. Release the Push-to-Talk button when finished.

5.4 Door Release Function

If an electric strike is connected via an RY-PA relay, the Door Release button allows you to remotely unlock the entrance for a visitor.

  1. Establish communication with the door intercom.
  2. Press the Door Release button to activate the electric strike.

5.5 Privacy Function

The Privacy button prevents other intercom users in the system from overhearing a conversation with another intercom, ensuring confidentiality.

  1. During a conversation, press the Privacy button to activate privacy mode.
  2. Press the Privacy button again to deactivate it.

5.6 Monitoring Function

The master intercom allows you to listen to audio transmissions from a specified door or sub-master intercom at any time.

  1. Select the desired door or sub-master intercom button.
  2. The master intercom will monitor audio from that location without requiring the Push-to-Talk button to be held.

5.7 Silencing Chime Alerts

To temporarily silence incoming call chime alerts, switch the power button to the 'off' position. This will only silence the chime, not power down the unit entirely.

6. Maintenance

6.1 Cleaning

To clean the intercom unit, gently wipe the surface with a soft, dry cloth. Do not use abrasive cleaners, solvents, or excessive moisture, as these can damage the unit.

6.2 Regular Checks

Periodically check all wiring connections to ensure they are secure. Ensure the unit is free from dust accumulation, especially around vents or speaker grilles.

7. Troubleshooting

If you experience issues with your Aiphone LEF-10S intercom, consider the following common troubleshooting steps:

If problems persist after attempting these steps, please contact Aiphone customer support or a qualified technician.

8. Specifications

SpecificationDetail
Overall Dimensions (H x W x D)8-1/8 x 7-1/2 x 2-3/16 inches (approx. 20.6 x 19.1 x 5.6 cm)
Communication Output (Reception)800mW at 20 ohms
Communication Output (Transmission)500mW at 20 ohms
Max. Distance (Door/Sub to Master, 22 AWG)650 ft. (approx. 198 meters)
Max. Distance (Door/Sub to Master, 18 AWG)1,600 ft. (approx. 488 meters)
Door Strike ConnectionAiphone RY-PA relay (sold separately)
Power RequirementsAiphone PS-1225UL 12V power supply (sold separately)
Mounting TypeSurface Mount
Housing MaterialWhite Plastic

9. Warranty and Support

For detailed warranty information, please refer to the documentation included with your purchase or visit the official Aiphone website. Aiphone meets International Organization for Standardization (ISO) standards 9001 and 14001.

For technical support, troubleshooting assistance beyond this manual, or to inquire about replacement parts, please contact Aiphone customer service directly.

Related Documents - LEF-10S

Preview Aiphone LEF-LD Loudspeaker Intercom System: Instructions and Wiring
Detailed instructions and wiring diagrams for the Aiphone LEF-LD Long Distance Loudspeaker Intercom System, covering models LEF-3-LD, LEF-5-LD, LEF-10-LD, LEF-10S-LD, LEF-3C-LD, LEF-5C-LD, and LEF-10C-LD.
Preview Aiphone IC-1AD(U) Chime Tone Intercom System: Installation and Operation Guide
Comprehensive guide for the Aiphone IC-1AD(U) 1-door, 1-room chime tone intercom system, covering features, specifications, installation, wiring, operation, and warranty.
Preview Aiphone IX Series Master Station Operation Guide
A comprehensive operation guide for the Aiphone IX Series Master Station, detailing basic functions, button operations, and status indicators.
Preview Aiphone IX|IXG Series Programming Quick Start Guide
A quick start guide for configuring Aiphone IX|IXG Series intercom systems using the IXG Support Tool, covering system setup, unit configuration, network settings, and advanced features.
Preview Aiphone JOW-2D Two Door Adaptor for JO Series Video Intercom System - Installation Guide
Detailed instructions and specifications for the Aiphone JOW-2D adaptor, enabling two door stations for the JO Series video intercom system. Learn about wiring, power, and operational features for intercom installations.
Preview Aiphone GT-1C Tenant Station Operation Guide
Comprehensive operation guide for the Aiphone GT-1C Tenant Station. Learn about its power source, LCD screen, speaker, microphone, and the functions of buttons like Door Release, Option, Guard, Talk, and Off, along with side controls for brightness, volume, and zoom.