Rossmax AC 701 Blood Pressure Monitor User Manual

Model: AC701 Kca

1. Introduction

The Rossmax AC 701 Blood Pressure Monitor is a reliable, automatic device designed for accurate blood pressure measurement at home. Utilizing Real Fuzzy and innovative technology, it provides precise readings and features a one-touch operation for ease of use. This manual will guide you through the proper setup, operation, maintenance, and troubleshooting of your device to ensure optimal performance and longevity.

Key features include:

  • Hypertension Risk Indicator
  • Irregular Heartbeat Detector (IHB)
  • Average of last 3 readings
  • One-touch automatic operation
  • Latex-free patented cone cuff
  • 120 record memory for 2 users with date and time

2. Setup

2.1 Battery Installation

Your Rossmax AC 701 monitor requires 4 AA batteries. Locate the battery compartment on the back or bottom of the device. Open the cover, insert the batteries according to the polarity indicators (+ and -), and close the cover securely.

2.2 Connecting the Cuff

Connect the air tube from the cuff securely into the air jack located on the side of the monitor. Ensure a snug fit to prevent air leakage during measurement.

Rossmax AC 701 Blood Pressure Monitor with cuff

Figure 2.1: Rossmax AC 701 Blood Pressure Monitor and Cuff

Rossmax Blood Pressure Cuff showing proper arm placement

Figure 2.2: Proper Cuff Placement on the Arm

3. Operating Instructions

3.1 Before Measurement

  • Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes before measurement.
  • Rest for at least 15 minutes before taking a measurement.
  • Sit in a comfortable position with your back supported and feet flat on the floor.
  • Place the cuff directly on your bare upper arm, approximately 1.5-2.5 cm above the elbow joint, with the air tube facing downwards.

3.2 Taking a Measurement

The Rossmax AC 701 features a simple one-touch automatic operation:

  1. Ensure the cuff is correctly applied to your arm.
  2. Press the START/STOP button. The cuff will automatically inflate to the appropriate pressure.
  3. Remain still and silent during the measurement.
  4. Once the measurement is complete, your Systolic (SYS), Diastolic (DIA), and Pulse readings will be displayed on the screen. The device will also indicate if an Irregular Heartbeat (IHB) or Hypertension Risk is detected.
Rossmax AC 701 Blood Pressure Monitor display

Figure 3.1: Rossmax AC 701 Monitor Display

3.3 Memory Function

The device can store 120 records for two users, complete with date and time stamps. It also provides an average of the last three readings. To access stored readings, press the 'M' (Memory) button. Pressing it repeatedly will cycle through the stored measurements.

4. Maintenance

4.1 Cleaning

Wipe the monitor and cuff with a soft, dry cloth. If necessary, use a cloth lightly dampened with water or a mild detergent, then wipe dry. Do not use abrasive cleaners or immerse the device in water.

4.2 Storage

Store the device in a clean, dry place, away from direct sunlight, extreme temperatures, and humidity. Keep it out of reach of children.

4.3 Battery Replacement

When the low battery indicator appears on the display, replace all four AA batteries with new ones simultaneously. Do not mix old and new batteries or different types of batteries.

5. Troubleshooting

If you encounter issues with your Rossmax AC 701, please refer to the following common problems and solutions:

ProblemPossible CauseSolution
Device does not power onBatteries are dead or incorrectly inserted.Check battery polarity or replace with new AA batteries.
Error message on displayCuff not properly connected, movement during measurement, or irregular pulse.Ensure cuff is securely connected. Remain still and silent. If IHB is frequent, consult a healthcare professional.
Inaccurate readingsImproper cuff placement, movement, talking, or recent activity.Re-read Section 3.1 and 3.2. Ensure proper preparation and technique. Take multiple readings and average them.
Cuff does not inflateAir tube disconnected or kinked.Check that the air tube is firmly connected to the monitor and not kinked.

If the problem persists after attempting these solutions, please contact customer support.

6. Specifications

SpecificationDetail
Model NumberAC701 Kca
Display TypeDigital
Measurement MethodOscillometric
Measurement LocationUpper Arm
Power Source4 AA batteries (not included)
Product Dimensions17.1 x 11.6 x 10.8 cm
Item Weight940 g
Memory Capacity120 records for 2 users
Included ComponentsDigital BP Monitor, Cuff

7. Warranty and Support

For warranty information or technical support, please contact Rossmax International Ltd. directly. Keep your purchase receipt as proof of purchase.

Manufacturer Contact Information:
Rossmax International Ltd.
12F, No. 189, Kang Chien Road, Taipei, 114, Taiwan
Phone: 9972528266
Email: cs@newnik.com

© 2024 Rossmax International Ltd. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.