Introduction
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Fasco A118 Draft Inducer Blower. Please read this manual thoroughly before attempting any installation or service procedures. Retain this manual for future reference.
The Fasco A118 Draft Inducer Blower is designed to expel exhaust gases from a furnace, ensuring proper ventilation and combustion efficiency.
Safety Information
WARNING: Risk of electric shock, fire, or injury. Installation and servicing must be performed by a qualified technician.
- Always disconnect power to the furnace before installing or servicing the inducer blower.
- Wear appropriate personal protective equipment (PPE), including gloves and eye protection.
- Ensure all wiring connections comply with local and national electrical codes.
- Do not operate the blower if it is damaged or if any components are missing.
- Keep hands and loose clothing away from moving parts.
- This product is intended for use in HVAC systems as a furnace inducer motor. Do not use for other applications.
Setup and Installation
Pre-Installation Checks
- Verify that the Fasco A118 is the correct replacement part for your furnace model.
- Inspect the blower for any shipping damage. Do not install if damaged.
- Ensure all necessary tools and materials are available.
Mounting Instructions
- Disconnect the furnace from its power source.
- Carefully remove the old inducer blower, noting its orientation and connections.
- Position the Fasco A118 in the same orientation as the removed unit.
- Secure the blower to the furnace housing using appropriate fasteners. Ensure a tight seal to prevent exhaust leaks.
Electrical Connections
- Connect the electrical wiring from the furnace to the Fasco A118, matching the wiring configuration of the original unit. Refer to the furnace manufacturer's wiring diagram.
- Ensure all connections are secure and insulated.
- Do not apply power until all connections are verified and the unit is properly mounted.
Figure 1: Fasco A118 Draft Inducer Blower. This image displays the complete Fasco A118 Draft Inducer Blower assembly. It features a cylindrical motor attached to a volute-shaped fan housing, with an exhaust outlet visible on the top left. Mounting brackets are present around the housing.
Operating Instructions
Once installed, the Fasco A118 Draft Inducer Blower operates automatically as part of the furnace's combustion cycle. When the thermostat calls for heat, the furnace control board initiates the inducer blower. The blower creates a negative pressure within the combustion chamber, drawing in fresh air and expelling exhaust gases through the vent system.
- Ensure the furnace vent system is clear of obstructions.
- Listen for normal operating sounds; unusual noises may indicate a problem.
- Observe the furnace's ignition sequence to confirm proper inducer operation.
Maintenance
Regular maintenance helps ensure the longevity and efficient operation of your Fasco A118 Draft Inducer Blower.
Annual Inspection
- Disconnect power to the furnace.
- Inspect the blower wheel for dirt, debris, or corrosion. Clean if necessary.
- Check the motor for any signs of overheating or unusual wear.
- Examine mounting bolts and electrical connections for tightness and integrity.
- Ensure the exhaust vent pipe connected to the inducer is clear and free of obstructions.
Cleaning
If the blower wheel is dirty, carefully remove the inducer assembly (after disconnecting power) and use a soft brush or vacuum to remove accumulated dust and debris. Avoid using harsh chemicals or solvents that could damage components.
Troubleshooting
If your Fasco A118 Draft Inducer Blower is not functioning correctly, consult the following table. Always disconnect power before inspecting or servicing the unit.
| Problem | Possible Cause | Solution |
|---|---|---|
| Blower does not start | No power, faulty wiring, seized motor, faulty control board. | Check power supply and circuit breaker. Inspect wiring connections. If motor is seized, replacement may be necessary. Consult a qualified technician for control board issues. |
| Unusual noise (grinding, squealing) | Worn bearings, debris in blower wheel, loose mounting. | Disconnect power and inspect blower wheel for debris. Check mounting bolts for tightness. Worn bearings typically require unit replacement. |
| Furnace not igniting after blower starts | Blocked vent, faulty pressure switch, faulty igniter. | Check for obstructions in the exhaust vent. Inspect pressure switch hose for cracks or blockages. Consult a qualified technician for pressure switch or igniter issues. |
| Blower runs continuously | Faulty control board, stuck relay. | Consult a qualified technician to diagnose and repair the control board or relay. |
Specifications
| Specification | Value |
|---|---|
| Brand | Fasco |
| Model Number | A118 |
| Speed | 3000 rpm |
| Voltage | 115 volts |
| Item Weight | 10 pounds |
| UPC | 815585025795 |
Warranty Information
Fasco products are manufactured to high-quality standards. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or contact Fasco directly. Keep your proof of purchase for warranty claims.
Support
If you require further assistance, have questions about installation, or need to troubleshoot issues not covered in this manual, please contact a qualified HVAC technician or Fasco customer support. Do not attempt repairs beyond your technical capabilities.