Yellow Jacket 95760

Yellow Jacket 95760 Refrigerant Recovery Machine User Manual

Model: 95760 | Brand: Yellow Jacket

Introduction

This user manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of the Yellow Jacket 95760 Refrigerant Recovery Machine. This machine is designed for the recovery of various refrigerants from HVAC/R systems. Please read this manual thoroughly before operating the unit to ensure proper usage and to prevent damage or injury.

Safety Information

Always observe the following safety precautions when operating the Yellow Jacket 95760 Refrigerant Recovery Machine:

Product Overview

The Yellow Jacket 95760 is a compact and powerful refrigerant recovery machine. Below is an illustration of the unit with its key components:

Front view of the Yellow Jacket 95760 Refrigerant Recovery Machine, showing gauges, control knobs, and power switches.

Figure 1: Front Panel of the Yellow Jacket 95760 Recovery Machine.

This image displays the front control panel of the Yellow Jacket 95760 Refrigerant Recovery Machine. Visible components include the blue and red pressure gauges for suction and discharge, respectively. Below the gauges are the main control knob with settings for LIQUID, PURGE, OFF, and VAPOR. To the left, there is a SUCTION port connection, and to the right, a DISCHARGE port connection. At the bottom center, there is a yellow "RECOVERY COMPLETE" indicator light, a "POWER" switch (I/O), and a "BREAKER" switch. The front also features a label for "YELLOW JACKET RecoverXLT REFRIGERANT RECOVERY SYSTEM" and a note about a "200 MESH FILTER UNDER FITTING CLEAN FREQUENTLY".

Key Components:

Setup

Before operating the recovery machine, ensure proper setup:

  1. Place the recovery machine on a stable, level surface in a well-ventilated area.
  2. Connect the appropriate refrigerant hoses to the system being recovered and to the recovery machine's SUCTION port.
  3. Connect a separate refrigerant hose from the machine's DISCHARGE port to the designated recovery tank. Ensure the recovery tank is empty or has sufficient capacity and is rated for the refrigerant type.
  4. Verify all connections are tight to prevent leaks.
  5. Plug the machine into a grounded 115V AC power outlet.

Operating Instructions

Refrigerant Recovery (Vapor Phase):

  1. Ensure the main control knob is set to VAPOR.
  2. Open the valves on the system and the recovery tank.
  3. Turn on the machine by pressing the POWER switch to 'I'.
  4. Monitor the suction gauge. Recovery is complete when the gauge reads 0 PSI or a deep vacuum is achieved, and the RECOVERY COMPLETE indicator illuminates.
  5. Once recovery is complete, close the valves on the system and the recovery tank.
  6. Turn off the machine by pressing the POWER switch to 'O'.

Refrigerant Recovery (Liquid Phase):

  1. Ensure the main control knob is set to LIQUID.
  2. Follow steps 2-6 from the Vapor Phase Recovery. The machine will recover liquid refrigerant more quickly.

Purging the Machine:

After recovery, it is recommended to purge the machine to remove any residual refrigerant.

  1. With the machine off and connected to an empty recovery tank, set the main control knob to PURGE.
  2. Turn on the machine. The machine will self-purge any remaining refrigerant into the recovery tank.
  3. Allow the machine to run until the suction gauge reads 0 PSI.
  4. Turn off the machine and disconnect hoses.

Maintenance

Regular maintenance ensures optimal performance and longevity of your recovery machine:

Troubleshooting

ProblemPossible CauseSolution
Machine does not power on.No power to outlet; Power switch off; Breaker tripped.Check power supply; Ensure power switch is 'I'; Reset BREAKER switch.
Slow recovery rate.Clogged 200 mesh filter; Partially closed valves; Kinked hoses; System pressure too low.Clean 200 mesh filter; Fully open all valves; Straighten hoses; Ensure adequate system pressure.
Machine cycles on/off frequently.Overheating; High discharge pressure.Allow machine to cool; Ensure recovery tank is not overfilled or too warm; Check for blockages in discharge line.
Refrigerant leaks.Loose connections; Damaged hoses or O-rings.Tighten all fittings; Inspect and replace damaged hoses or O-rings.

Specifications

FeatureDetail
Model Number95760
BrandYellow Jacket
Motor HP1/2 hp
Voltage115 V
Electrical ConnectionsNEMA 5-15p Male Plug
Hose Connection1/4 in Male
Operating Temperature Range40°F to 120°F (4°C to 49°C)
Compressor TypeOilless
Product Dimensions15 x 12 x 21 inches
Item Weight28 pounds
Date First AvailableMay 24, 2007

Warranty and Support

For warranty information, technical support, or service inquiries regarding your Yellow Jacket 95760 Refrigerant Recovery Machine, please refer to the official Yellow Jacket website or contact their customer service department. The product typically includes an instruction guide, and a PDF user manual is also available online for detailed reference.

You can find additional resources and contact information on the manufacturer's official website: www.yellowjacket.com

Related Documents - 95760

Preview Yellow Jacket RecoverXLT and RecoverX Refrigerant Recovery Machines
Comprehensive guide to Yellow Jacket's RecoverXLT and RecoverX refrigerant recovery machines, detailing features, specifications, operation, and comparison charts for HVAC/R professionals.
Preview Yellow Jacket HVAC/R Charging Systems & Diagnostic Tools Catalog
This catalog showcases Yellow Jacket's comprehensive range of HVAC/R charging systems and diagnostic tools, including the YJACK™ Series wireless sensors, P51 TITAN® Digital Manifolds, ManTooth® Wireless Gauges, and various BRUTE II® and Series 41 manifolds. The products are designed for accurate measurements, efficient system analysis, and enhanced user experience in HVAC/R applications.
Preview Yellow Jacket TitanMax Digital Manifold - Features and Specifications
Explore the Yellow Jacket TitanMax Digital Manifold, a 4-valve system offering fast and accurate measurements for refrigeration and A/C systems. Features include a high-resolution touchscreen, wireless connectivity via Bluetooth to YJACK VIEW® and measureQuick® apps, on-board data logging, and compatibility with A2L refrigerants.
Preview YELLOW JACKET® TITANMAX™ Digital Manifold User Manual
Comprehensive user manual for the YELLOW JACKET® TITANMAX™ digital manifold (models 40880, 40881, 40885, 40887). Covers HVAC system diagnostics, pressure, temperature, vacuum, leak testing, psychrometric analysis, datalogging, and YJACK VIEW® app integration. Includes safety, maintenance, and troubleshooting.
Preview YELLOW JACKET TITANMAX™ User Manual
Comprehensive user manual for the YELLOW JACKET TITANMAX™ digital manifold, detailing its features, operation, settings, maintenance, and troubleshooting for HVAC professionals. Includes model numbers P/N 40880, 40881, 40885, 40887.
Preview Yellow Jacket TITANMAX™ Digital Manifold Quick Start Guide
Quick start guide for the Yellow Jacket TITANMAX™ Digital Manifold, covering setup, connections, main features, and settings for HVAC technicians. Learn how to power on, connect probes, navigate menus, and configure settings for pressure, temperature, vacuum, and psychrometric measurements.