SureCall SC-METER-01 Five-Band RF Signal Meter Instruction Manual
Brand: SureCall | Model: SC-METER-01
Introduction
The SureCall SC-METER-01 Five-Band RF Signal Meter is an essential tool designed for accurately measuring wireless signal strength across various cellular bands. This device supports voice, 3G, 4G LTE, PCS, and AWS frequencies used by all major North American cellular carriers. Its primary purpose is to assist in determining the optimal location for installing outside antennas to achieve the best possible signal coverage for cell phone signal boosters. The meter's portability ensures convenience for use in diverse environments.
- Five Bands Supported: 1930-1995 PCS, 869-894 Cellular, 2110-2155 AWS, 746-757 LTE, and 728-746 LTE.
- Extended Working Time: Operates for 2.5 to 3.5 hours on a full charge.
- Rechargeable Power: Utilizes four included AAA NiMH rechargeable batteries.
- Enhanced Visibility: Features a controllable backlight for clear readings in low-light conditions.
- High Sensitivity: Capable of receiving signals with sensitivity up to -110dBm.
What's in the Box
Your SureCall SC-METER-01 package includes the following components:
- RF Signal Meter (SC-METER-01)
- 110 AC Power Adapter
- Right Angle Antenna
- 9” SMA-Male to N-Male Cable Connector
- 24” SMA-Male to N-Male Cable Connector
- 4 AAA Rechargeable Batteries (pre-installed)
- User Manual

Image: The SureCall SC-METER-01 RF Signal Meter shown with its right angle antenna, power adapter, and connecting cables.
Setup and Installation
Proper setup of your RF Signal Meter is crucial for accurate readings. Follow these steps to prepare your device for use:
- Install Batteries: The SC-METER-01 comes with 4 AAA rechargeable batteries pre-installed. Ensure they are charged using the provided 110 AC Power Adapter before first use.
- Attach Right Angle Antenna: Screw the included right angle antenna onto the SMA connector at the top of the RF Signal Meter.
- Connect External Antenna (Optional): If using an external antenna (e.g., for a cell phone signal booster installation), connect one of the provided SMA-Male to N-Male cables (9” or 24”) to the meter's SMA port. The N-Male end will connect to your external antenna.

Image: Front view of the SureCall SC-METER-01 RF Signal Meter with its display and control buttons.

Image: A close-up view of the SureCall SC-METER-01 RF Signal Meter's keypad, showing the 'Mode Select', 'Band Select', 'Prev Freq', and 'Next Freq' buttons.
Video Guide: How it Works
Video: An official SureCall video demonstrating the functionality and operation of the RF Signal Meter.
Operating Instructions
The SureCall SC-METER-01 is designed for ease of use. Familiarize yourself with the controls and display to effectively measure signal strength.
- Power On/Off: Locate the power button on the device and press it to turn the meter on or off.
- Mode Selection: Use the 'Mode Select' button to cycle through different operating modes. Each mode provides specific information about the signal.
- Band Selection: Use the 'Band Select' button to choose the specific frequency band you wish to measure (e.g., PCS, Cellular, AWS, LTE).
- Frequency/Block Navigation: Use the 'Prev Freq' and 'Next Freq' arrow buttons to navigate through different frequencies or blocks within the selected band.
- Reading Signal Strength: The display will show the signal strength in dBm. A higher (less negative) dBm value indicates a stronger signal.
- Backlight Control: Press the light bulb icon button to toggle the display backlight on or off for visibility in various lighting conditions.

Image: A close-up view of the SureCall SC-METER-01 RF Signal Meter's screen, displaying signal information such as mode, LTE band, block, and power level in dBm.
Maintenance
To ensure the longevity and optimal performance of your SureCall SC-METER-01 RF Signal Meter, follow these maintenance guidelines:
- Battery Care: Regularly charge the AAA NiMH batteries. If the device will not be used for an extended period, fully charge the batteries and store the device in a cool, dry place.
- Cleaning: Use a soft, dry cloth to clean the device. Avoid using harsh chemicals or abrasive materials that could damage the screen or casing.
- Storage: Store the meter in a protective case when not in use to prevent physical damage.
- Environmental Conditions: Avoid exposing the device to extreme temperatures, direct sunlight for prolonged periods, or moisture.
Troubleshooting
If you encounter issues with your SureCall SC-METER-01, refer to the following common troubleshooting steps:
- No Power: Ensure the batteries are fully charged. If using the AC adapter, verify it is properly connected to a working power outlet.
- Inaccurate Readings: Check that the antenna is securely attached. Ensure you are in an area with at least some existing cellular signal. Obstructions like thick walls or dense foliage can affect readings.
- Display Issues: If the backlight is not working, press the light bulb button. If the screen is unresponsive, try turning the device off and on again.
- Weak Signal Detection: Confirm the external antenna (if used) is correctly pointed towards the nearest cell tower. Adjust the direction of the external antenna for optimal signal reception.
Specifications
| Product Dimensions | 8 x 3 x 9 inches |
| Item Weight | 14.4 ounces |
| Item Model Number | SC-METER-01 |
| Batteries | 4 AAA NiMH batteries (included) |
| Special Features | Signal strength measurement, frequency level mapping, peak antenna alignment |
| Wireless Communication Standard | Radio Frequency |
| Color | Red |
| Manufacturer | Microcom Technologies, Inc-wireless |
| Date First Available | August 10, 2013 |
Warranty and Support
SureCall is committed to providing high-quality products and excellent customer service.
- Warranty: Please refer to the included User Manual for detailed warranty information.
- Technical Support: For any technical assistance or questions regarding your SC-METER-01, please contact SureCall's 100% US-based signal experts.
- Contact Information: Visit the SureCall Store on Amazon or consult your User Manual for direct contact details.