1. Important Safety Information

Please read all safety instructions carefully before installing or operating the LSE Lighting GPH793T5L/4P UV-C Replacement Lamp. Failure to follow these instructions may result in serious injury or damage to the product.

  • UV-C Radiation Hazard: UV-C light is extremely harmful to eyes and skin. NEVER look directly at an illuminated UV-C lamp. Avoid direct exposure to UV-C radiation.
  • Protective Gear: Always wear appropriate UV-protective eyewear (goggles or face shield) and skin protection (long sleeves, gloves) when handling or working near an active UV-C lamp.
  • Installation: Ensure the power supply to the UV system is completely disconnected before attempting installation, removal, or maintenance of the lamp.
  • Handling: Do not touch the glass surface of the lamp with bare hands. Oils from your skin can create hot spots, reducing lamp life. If the lamp is accidentally touched, clean it with a high-strength isopropyl alcohol wipe before installation.
  • Disposal: UV-C lamps contain mercury. Dispose of lamps according to local, state, and federal regulations. Do not dispose of in regular household waste.
  • Compatibility: Use this lamp only in UV systems designed for GPH793T5L/4P or GPH793T5L/4 lamps. Using an incompatible lamp may cause system malfunction or damage.
  • Children and Pets: Keep UV-C lamps and systems out of reach of children and pets.
LSE Lighting UV-C lamp packaging with warning label

Image: Packaging of the LSE Lighting UV-C lamp, showing important safety warnings regarding UV light exposure.

2. Product Overview

The LSE Lighting GPH793T5L/4P is a high-output UV-C replacement lamp designed for effective germicidal treatment in various air and water purification systems. This lamp emits ultraviolet light at a wavelength of 254nm, which is highly effective in neutralizing microorganisms.

Key Features:

  • High-Output UV-C Performance: Operates at 40 watts and 425mA, emitting 254nm germicidal ultraviolet light.
  • Precision Design: Measures 793mm (31.22 inches) with a single-ended 4-pin base.
  • Compatibility: Direct replacement for UV systems requiring GPH793T5L/4P or GPH793T5L/4 lamps.
  • Quality Manufacturing: Built in EPA Registered Establishment No. 96823-PA-1 and engineered in the USA.
LSE Lighting GPH793T5L/4P UV-C lamp key features

Image: A visual summary of the key features of the LSE Lighting GPH793T5L/4P UV-C lamp, including its specifications and EPA registration.

Video: An introduction to LSE Lighting, highlighting the company's commitment to UV light technology and product quality.

3. Setup and Installation

This section provides general guidelines for installing the LSE Lighting GPH793T5L/4P UV-C Replacement Lamp. Always refer to your specific UV system's instruction manual for detailed installation procedures.

Installation Steps:

  1. Power Disconnection: Ensure the power to the UV system is completely turned off and unplugged before beginning any work.
  2. Access Lamp Housing: Open the UV system's lamp housing according to the manufacturer's instructions.
  3. Remove Old Lamp: Carefully remove the old UV lamp. Note its orientation and how it connects to the lamp base.
  4. Handle New Lamp: While wearing gloves, carefully unpackage the new LSE Lighting GPH793T5L/4P lamp. Avoid touching the glass with bare hands. If accidental contact occurs, clean the glass with isopropyl alcohol.
  5. Insert New Lamp: Align the 4-pin base of the new lamp with the receptacle in the UV system. Gently push the lamp into place until it is securely seated. Do not force the lamp.
  6. Secure Housing: Close and secure the lamp housing of the UV system.
  7. Restore Power: Plug in the UV system and restore power. Verify proper operation according to your system's indicators.

Note: Professional installation is recommended for complex UV systems or if you are unsure about any step.

LSE Lighting GPH793T5L/4P UV-C lamp with 4-pin base

Image: Close-up view of the LSE Lighting GPH793T5L/4P UV-C lamp, highlighting its single-ended 4-pin base for proper installation.

4. Operation

Once installed, the LSE Lighting GPH793T5L/4P UV-C lamp operates automatically within your compatible UV system. The lamp emits germicidal UV-C light to purify air or water.

Applications:

  • Air Treatment: Used in HVAC systems, air purifiers, and other air handling units to reduce airborne pathogens, mold spores, and other contaminants.
  • Water Treatment: Integrated into water purification systems for residential, commercial, and industrial use to disinfect water by inactivating bacteria, viruses, and protozoa.

The lamp's 254nm wavelength is specifically chosen for its germicidal effectiveness, disrupting the DNA of microorganisms and preventing their reproduction.

Various applications of LSE Lighting UV-C lamps in residential, commercial, and industrial settings

Image: Illustrates diverse environments where LSE Lighting UV-C lamps are utilized, including residential, commercial, schools, hospitals, food service, and industrial applications.

LSE Lighting UV-C lamp used for air purification applications

Image: Depicts the LSE Lighting UV-C lamp integrated into air handling systems for air purification, showing before and after scenarios of filter cleanliness.

LSE Lighting UV-C lamp used for water treatment applications

Image: Shows the LSE Lighting UV-C lamp in use for water treatment, illustrating its role in providing clean, purified water for drinking and other uses.

5. Maintenance

Regular maintenance ensures the optimal performance and longevity of your LSE Lighting GPH793T5L/4P UV-C lamp and the overall UV system.

Maintenance Guidelines:

  • Lamp Replacement: UV-C lamps have a finite effective life. While the lamp may still glow, its germicidal effectiveness diminishes over time. Replace the lamp according to your UV system manufacturer's recommendations, typically every 9-12 months, or as indicated by your system's lamp life monitor.
  • Cleaning: If the quartz sleeve (if applicable) or the lamp itself becomes dirty, turn off and unplug the system. Allow the lamp to cool. Wearing gloves, carefully remove the lamp or sleeve and clean it with a lint-free cloth dampened with isopropyl alcohol. Do not use abrasive cleaners.
  • Visual Inspection: Periodically inspect the lamp and its connections for any signs of damage, discoloration, or loose connections. If any damage is observed, replace the lamp immediately.
Comparison of UV lamp intensity over time and quality assurance process

Image: Graph illustrating the stable UV intensity maintenance of LSE Lighting lamps (above 80% for 13,000 hours) compared to other lamps with shorter effective life, alongside visuals of quality assurance and EPA registration.

6. Troubleshooting

This section addresses common issues you might encounter with your LSE Lighting GPH793T5L/4P UV-C lamp. Always ensure the power is disconnected before performing any inspection or maintenance.

Common Issues and Solutions:

ProblemPossible CauseSolution
Lamp does not light upNo power to the system, faulty ballast, incorrect installation, or defective lamp.Check power supply. Ensure lamp is correctly seated. Test ballast if possible (refer to UV system manual). Replace lamp if other components are functional.
Lamp flickers or dimsLoose connection, aging lamp, or ballast issue.Ensure lamp is securely connected. If lamp is old, consider replacement. Consult UV system manual for ballast troubleshooting.
Reduced purification effectivenessAging lamp (reduced UV output), dirty quartz sleeve (if applicable), or incorrect system sizing.Replace lamp if it has exceeded its recommended life. Clean quartz sleeve. Verify system is correctly sized for your application.

If you continue to experience issues after following these troubleshooting steps, please contact LSE Lighting customer support or a qualified technician.

7. Specifications

Detailed technical specifications for the LSE Lighting GPH793T5L/4P UV-C Replacement Lamp.

FeatureDetail
Model NumberGPH793T5L/4P
BrandLSE Lighting
Light TypeUV-C (Germicidal Ultraviolet)
Wavelength254nm
Wattage40 Watts
Operating Current425mA
Bulb Shape SizeT5
Length793mm (31.22 inches)
Base TypeSingle-ended 4-Pin
MaterialGlass
EPA RegistrationEPA Registered Establishment No. 96823-PA-1
Voltage/Frequency100 to 240 Volts and 50 Hertz to 60 Hertz (System dependent)
Specific UsesUV-C System, Air Treatment, Water Treatment
Item Weight1 Pound
UPC798295449108

8. Warranty and Support

Warranty Information:

The LSE Lighting GPH793T5L/4P UV-C Replacement Lamp comes with a 1-year manufacturer's warranty. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims.

The warranty does not cover damage resulting from improper installation, misuse, accidental breakage, or normal wear and tear (e.g., diminished UV output over time, which is expected for all UV lamps).

Customer Support:

For technical assistance, warranty claims, or further inquiries, please contact LSE Lighting customer support. Refer to the LSE Lighting official website or your purchase documentation for current contact information.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.