KEYSTONE KTEB-2C72-1-TP
KEYSTONE KTEB-2C72-1-TP Electronic Fluorescent Ballast User Manual
Model: KTEB-2C72-1-TP
Introduction
This manual provides essential instructions for the safe installation, operation, and maintenance of the KEYSTONE KTEB-2C72-1-TP Electronic Fluorescent Ballast. Please read this manual thoroughly before installation and retain it for future reference. This ballast is designed to operate two F32T8 fluorescent lamps at 120 Volts.

Image: Keystone KTEB-2C72-1-TP Electronic Fluorescent Ballast. This image displays the compact design of the electronic ballast, typically a rectangular metal or plastic enclosure with wiring leads extending from it.
Important Safety Instructions
WARNING: Risk of electric shock. Disconnect power before installation or servicing.
- Installation should be performed by a qualified electrician in accordance with national and local electrical codes.
- Ensure the supply voltage matches the ballast's rated voltage (120V).
- Do not install in locations where the ambient temperature exceeds the ballast's maximum operating temperature.
- Do not connect to a dimming circuit unless the ballast is specifically rated for dimming.
- Ground the ballast properly to prevent electrical hazards.
Setup and Installation
Follow these steps for proper installation of the KTEB-2C72-1-TP ballast:
- Power Disconnection: Before beginning any work, ensure that the main power supply to the fixture is turned off at the circuit breaker. Verify with a voltage tester.
- Old Ballast Removal: If replacing an existing ballast, carefully disconnect all wires from the old ballast. Note the wiring configuration or take a photograph for reference. Remove the old ballast from the fixture.
- Mounting the New Ballast: Secure the new KEYSTONE KTEB-2C72-1-TP ballast inside the fixture using appropriate screws or mounting hardware. Ensure it is firmly attached to prevent vibration.
- Wiring Connections: Refer to the wiring diagram provided on the ballast label.
- Connect the black wire from the ballast to the 120V AC Line (hot) wire.
- Connect the white wire from the ballast to the 120V AC Neutral wire.
- Connect the green wire (or bare copper) from the ballast to the fixture's Ground wire.
- Connect the ballast's lamp wires to the fluorescent lamp holders (sockets) as indicated by the wiring diagram. This ballast supports two F32T8 lamps. Ensure all connections are secure and insulated.
- Lamp Installation: Insert the F32T8 fluorescent lamps into their respective lamp holders.
- Power Restoration: Once all connections are secure and lamps are installed, restore power at the circuit breaker.
- Testing: Turn on the light switch to verify proper operation.
Always consult the wiring diagram printed on the ballast itself for the most accurate and specific connection instructions.
Operating Instructions
The KEYSTONE KTEB-2C72-1-TP electronic ballast operates automatically once properly installed and powered. It provides the necessary voltage and current to ignite and sustain two F32T8 fluorescent lamps.
- Power On/Off: Use the standard wall switch connected to the fixture to turn the lamps on or off.
- Instant Start: This electronic ballast is designed for instant start operation, meaning lamps should illuminate immediately upon power application.
- Normal Operation: Lamps should provide consistent, flicker-free illumination.
Maintenance
The KTEB-2C72-1-TP ballast is designed for long-term, maintenance-free operation. However, periodic checks of the lighting fixture are recommended.
- Cleaning: Ensure the ballast and fixture are kept free of dust and debris to allow for proper heat dissipation. Disconnect power before cleaning.
- Lamp Replacement: Replace lamps with new F32T8 fluorescent lamps when they reach the end of their life or begin to flicker excessively. Always disconnect power before replacing lamps.
- Wiring Inspection: Periodically inspect wiring connections for any signs of wear, fraying, or loose terminals. Address any issues promptly after disconnecting power.
Troubleshooting
If the fluorescent lamps do not operate correctly, follow these troubleshooting steps:
| Problem | Possible Cause | Solution |
|---|---|---|
| Lamps do not turn on. |
|
|
| Lamps flicker or hum. |
|
|
| Only one lamp illuminates. |
|
|
If troubleshooting does not resolve the issue, contact a qualified electrician or KEYSTONE customer support.
Specifications
Key technical specifications for the KEYSTONE KTEB-2C72-1-TP Electronic Fluorescent Ballast:
- Model: KTEB-2C72-1-TP
- Brand: KEYSTONE
- Ballast Type: Electronic, Instant Start
- Lamp Compatibility: Two (2) F32T8 Fluorescent Lamps
- Input Voltage: 120 Volts AC
- Input Current: 0.85 Amps
- Wattage: 32 Watts (per lamp, nominal)
- Frequency: 60 Hertz
- Power Factor: High
- Operating Temperature: Consult ballast label for specific range.
- Dimensions: Approximately 1"W x 2"H (Note: Product dimensions often refer to packaging or a specific part; actual ballast dimensions may vary slightly. Refer to manufacturer's datasheet for precise measurements.)
- Indoor/Outdoor Usage: Outdoor (Type 1 Outdoor rated)
- Efficiency: Electronic
- Certifications: UL Listed, CSA Certified (typically, verify on product label)
Warranty and Support
For warranty information and technical support, please refer to the official KEYSTONE Technologies website or contact their customer service directly. Warranty terms typically cover defects in materials and workmanship under normal use and service.
Manufacturer: Keystone Technologies
Contact: Refer to Keystone Technologies Official Website for support contact details.
Ask a question about this manual