1. Product Overview
The Square D D322NRB General Duty Safety Switch is a robust electrical disconnect designed for both residential and commercial applications. It provides a reliable means to turn power on or off to specific loads, ensuring safety and control within electrical systems. This model is a fusible type, offering protection against overcurrents when equipped with appropriate fuses.
Key features include:
- 4-wire design: Includes 3 blades and fuse holders, plus 1 neutral connection.
- Voltage Rating: Operates at 120/240 Volts AC.
- Current Rating: Rated for 60 Amperes.
- Enclosure Type: NEMA Type 3R metallic enclosure, suitable for outdoor use.
- Horsepower Rating: 3.0/10.0 HP at 240 Vac single phase (Standard/Maximum).
- UL Listed: Certified for safety and performance.

Figure 1: Front view of the Square D D322NRB General Duty Safety Switch, showing the gray metallic enclosure and the operating handle in the 'ON' position. A warning label is visible on the front cover.
2. Safety Information
WARNING: HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH.
This safety switch must be installed, operated, serviced, and maintained only by qualified electrical personnel. Failure to follow these instructions will result in death or serious injury.
- Always use a properly rated voltage sensing device to confirm power is OFF.
- Turn off all power supplying this equipment before working on or inside the switch.
- Never operate an energized switch with the door open.
- Lock out and tag the switch before removing or installing fuses or making load side connections.
- Do not use renewable link type fuses.
- Ensure proper grounding according to local and national electrical codes.
Refer to NFPA 70E for additional safety practices.
3. Setup and Installation
Installation of the D322NRB safety switch should only be performed by qualified electricians in accordance with all applicable national and local electrical codes.
3.1 Mounting the Switch
- Select a suitable outdoor location for the NEMA Type 3R enclosure, ensuring it is easily accessible for operation and maintenance.
- Securely mount the switch enclosure to a rigid surface using appropriate hardware through the designated mounting holes.
3.2 Wiring Connections
- Ensure all power sources are disconnected and locked out before beginning any wiring.
- Open the enclosure door.
- Connect the incoming power supply conductors to the line terminals and the outgoing load conductors to the load terminals. This is a 3-pole switch with a neutral connection.
- Install the appropriate fuses into the fuse holders. Refer to the product label for correct fuse types and ratings.
- Connect the grounding conductor to the designated grounding lug within the enclosure.
- Verify all connections are tight and secure.

Figure 2: Angled view of the safety switch, highlighting the robust metallic enclosure and the external operating handle. Conduit knockouts are visible on the sides.
4. Operating Instructions
The D322NRB safety switch operates manually via the external handle.
4.1 Turning Power ON
- Ensure the enclosure door is fully closed.
- Move the operating handle to the 'ON' position. The handle should latch securely.
4.2 Turning Power OFF
- Move the operating handle to the 'OFF' position. The handle should latch securely.
- To perform maintenance or replace fuses, the handle must be in the 'OFF' position, and the switch should be locked out and tagged. The enclosure door can only be opened when the switch is in the 'OFF' position.

Figure 3: Side view of the safety switch, showing the depth of the enclosure and additional conduit entry points.
5. Maintenance
Regular maintenance helps ensure the longevity and safe operation of your safety switch. All maintenance should be performed by qualified personnel with power disconnected and locked out.
- Periodic Inspection: Annually inspect the enclosure for signs of damage, corrosion, or loose connections.
- Cleaning: Keep the exterior of the enclosure clean and free from debris. Do not use abrasive cleaners.
- Fuse Replacement: If a fuse blows, always replace it with a fuse of the same type and rating. Never bypass or use incorrect fuses. Ensure power is OFF and locked out before replacing fuses.
- Tighten Connections: Periodically check and tighten all electrical connections to prevent overheating and arcing.
6. Troubleshooting
If you experience issues with your D322NRB safety switch, consider the following common troubleshooting steps. Always ensure power is disconnected and locked out before inspecting the switch.
| Problem | Possible Cause | Solution |
|---|---|---|
| No power to load | Switch in 'OFF' position | Move handle to 'ON' position. |
| No power to load | Blown fuse(s) | Identify and replace blown fuse(s) with correct type and rating. |
| No power to load | Loose wiring connection | Inspect and tighten all connections. |
| Switch handle will not move to 'ON' | Enclosure door not fully closed | Ensure door is securely latched. |
| Overheating of switch or wires | Loose connections, overloaded circuit, incorrect wire gauge | Check connections, reduce load, verify wire gauge is appropriate for current. Consult a qualified electrician. |
7. Specifications
| Attribute | Value |
|---|---|
| Model Number | D322NRB |
| Brand | Square D by Schneider Electric |
| Current Rating | 60 Amps |
| Operating Voltage | 120/240 Volts AC |
| Number of Poles | 3 |
| Horsepower Rating | 3.0/10.0 HP (Standard/Maximum) |
| Enclosure Type | NEMA Type 3R (Outdoor Use) |
| Fusible | Yes |
| Operation Mode | Manual |
| Dimensions (L x W x H) | 4.87 x 7.45 x 14.88 inches |
| Item Weight | 8.49 pounds |
| Material | Metal |
| UPC | 785901461289 |
8. Warranty and Support
Schneider Electric products are manufactured to high standards and typically come with a manufacturer's warranty. For specific warranty details, terms, and conditions related to your Square D D322NRB safety switch, please refer to the documentation included with your product or visit the official Schneider Electric website.
8.1 Customer Support