1. Introduction

The Thermco BM2012ABLS Glass Accu-Safe Pocket Thermometer is a precision instrument designed for accurate temperature measurement within a range of -30 to 120°F, with 2°F divisions. This thermometer features a blue spirit-filled column against a white background for enhanced readability. It is constructed with a biodegradable liquid and dye, offering a safer alternative to mercury thermometers. Each unit is serialized and includes a Certificate of Accuracy, ensuring traceability and reliability.

2. Safety Information

3. Product Features

4. Setup

The Thermco BM2012ABLS thermometer requires minimal setup. Upon receiving your thermometer:

  1. Unpack: Carefully remove the thermometer from its packaging.
  2. Inspect: Visually inspect the thermometer for any signs of damage, such as cracks in the glass or separation in the liquid column. If any damage is observed, do not use the thermometer and contact customer support.
  3. Review Certificate: Keep the included Certificate of Accuracy for future reference regarding calibration and traceability.
Thermco BM2012ABLS Glass Accu-Safe Pocket Thermometer

Image 1: Thermco BM2012ABLS Glass Accu-Safe Pocket Thermometer. This image shows the thermometer with its protective casing, highlighting the blue spirit column and clear markings.

5. Operating Instructions

To obtain an accurate temperature reading:

  1. Remove from Casing: Carefully slide the thermometer out of its protective metal casing.
  2. Total Immersion: For accurate readings, ensure the thermometer bulb and the entire liquid column up to the expected temperature are fully immersed in the substance or environment being measured. The thermometer is designed for TOTAL Immersion.
  3. Stabilization: Allow sufficient time for the thermometer to stabilize to the ambient temperature. The response time is approximately 500 milliseconds, but for environmental measurements, allow several minutes for the reading to settle.
  4. Read Temperature: Read the temperature directly from the top of the blue liquid column. Ensure your eye level is horizontal with the top of the liquid column to avoid parallax error.
  5. Return to Casing: After use, carefully return the thermometer to its protective casing.

6. Maintenance

7. Troubleshooting

8. Specifications

SpecificationDetail
Model NameBM2012ABLS
BrandTHERMCO
Temperature Range-30 to 120°F
Division2°F
Immersion TypeTOTAL Immersion
Liquid TypeBlue Spirit (Biodegradable)
Outer MaterialGlass
Display TypeAnalog
Special FeatureHigh Accuracy
Specification MetNIST
Response Time500 Milliseconds
Immersion Depth10 Centimeters (approx.)
Indoor/Outdoor UsageOutdoor
Item Weight0.64 ounces
Product Care InstructionsWipe Clean

9. Warranty and Support

For warranty information or technical support regarding your Thermco BM2012ABLS thermometer, please refer to the documentation included with your purchase or contact Thermco Products Inc. directly. Contact details can typically be found on the manufacturer's official website or on the product packaging.

Related Documents - BM2012ABLS

Preview Thermco ACCRT8017 Dual Data Logging Thermometer User Manual & Specifications
User manual for the Thermco ACCRT8017 Dual Data Logging Thermometer. Features dual probes, high accuracy, large data logging capacity (24 million readings), user-configurable alarms, and CSV data format for fridge and freezer monitoring.
Preview THERMCO ACCRT8019UL Dual Data Logging Thermometer - Ultra Low Freezer
Detailed specifications, features, and operating instructions for the THERMCO ACCRT8019UL Dual Data Logging Thermometer. This device monitors ultra-low freezers with dual probes, offers SD card data logging, and user-configurable alarms.
Preview McKesson Refrigerator/Freezer Thermometer DUAL PROBE MCK8100MATB User Manual
Detailed user manual for the McKesson Refrigerator/Freezer Thermometer DUAL PROBE (MCK8100MATB). Includes features, specifications, setup instructions, settings configuration, and troubleshooting notes.
Preview McKesson Refrigerator/Freezer Thermometer TRIPLE DISPLAY DUAL PROBE MCK821RFV2 User Manual
User manual and specifications for the McKesson Refrigerator/Freezer Thermometer TRIPLE DISPLAY DUAL PROBE (Model MCK821RFV2). Features include high accuracy, min/max memory, low/high alarm settings, and NIST traceability.
Preview McKesson Wireless Refrigerator/Freezer Thermometer MCK895WRFT - Triple Display, Single Probe
User manual and specifications for the McKesson Wireless Refrigerator/Freezer Thermometer, model MCK895WRFT. Details features like triple display, single probe, large digit, wireless connectivity, alarm settings, and error codes.
Preview McKesson Refrigerator/Freezer Thermometer Data Logger Dual Probe MCK80022P
Detailed specifications, features, installation, operation, and display symbol guide for the McKesson Refrigerator/Freezer Thermometer Data Logger Dual Probe (MFR # MCK80022P).