1. Introduction

Thank you for choosing the Rossmax HA500 Non-Contact Temple Thermometer. This device is designed for accurate and convenient temperature measurement without physical contact, making it ideal for all age groups. Please read this manual thoroughly before use to ensure proper operation and to maintain the device's accuracy and longevity.

Rossmax HA500 Non-Contact Temple Thermometer showing a digital temperature reading

Image 1.1: Rossmax HA500 Non-Contact Temple Thermometer

Key Features:

  • Non-Contact Measurement: Reduces cross-contamination risk.
  • User-Friendly: Simple operation suitable for all ages.
  • Clear Digital Display: Shows temperature readings in Fahrenheit or Celsius.
  • Fast Readings: Provides near-instant temperature results (approximately 1 second).
  • Hygienic: No probe covers required.
  • Memory Function: Stores up to 9 previous readings.
  • Fever Alarm: Alerts when a high temperature is detected.
  • Backlight: For easy reading in low-light conditions.
  • Auto Shut-off: Conserves battery life.
  • Low Battery Indicator: Notifies when batteries need replacement.
Icons representing auto shut-off, low battery indicator, backlight, and high temperature alarm features

Image 1.2: Smart & Reliable Features of the HA500

What's in the Box:

  • Rossmax HA500 Non-Contact Temple Thermometer
  • Storage Case
  • 1 x LR44 Battery (pre-installed or included separately)
  • User Manual
Rossmax HA500 thermometer inside its clear plastic storage case

Image 1.3: Thermometer in Storage Case

2. Safety Information

Please observe the following safety precautions to ensure safe and accurate use of your thermometer:

  • Do not attempt to disassemble or modify the device.
  • Keep the device away from direct sunlight, high temperatures, and moisture.
  • Avoid dropping the thermometer or subjecting it to strong impacts.
  • Do not use the thermometer if the sensor or display is damaged.
  • Keep out of reach of children to prevent accidental ingestion of small parts or batteries.
  • Consult a medical professional for any health concerns, as thermometer readings are for reference only.
  • Ensure the measurement area (temple) is clean and free from hair or sweat for accurate readings.

3. Setup and Battery Installation

Battery Installation:

The Rossmax HA500 uses one LR44 battery. If the low battery indicator appears on the display, or if the device does not power on, replace the battery.

  1. Locate the battery compartment cover, usually on the back or side of the device.
  2. Gently slide or unclip the cover to open the compartment.
  3. Insert the LR44 battery, ensuring the correct polarity (+/-) as indicated inside the compartment.
  4. Close the battery compartment cover securely.
Back view of the Rossmax HA500 thermometer showing the 'START' button and battery compartment area

Image 3.1: Rear view of the thermometer, indicating the START button and battery area.

4. Operating Instructions

Taking a Temperature Measurement:

  1. Press the Power button to turn on the thermometer. The display will show a brief self-test.
  2. Position the thermometer sensor approximately 5 cm (2 inches) from the center of the temple area. Ensure there is no hair or obstruction.
  3. Press the 'START' button. A beep will sound, and the measurement will be taken within approximately 1 second.
  4. The temperature reading will be displayed on the screen. If a fever is detected, an alarm may sound.
  5. The device will automatically shut off after a period of inactivity to conserve battery.
Digital display of the thermometer showing a temperature reading and '1 SEC' indicating fast measurement

Image 4.1: Fast 1-second measurement

Switching Temperature Units (°C/°F):

To switch between Celsius and Fahrenheit, ensure the device is off. Press and hold the 'START' button for a few seconds until the unit changes on the display. Release the button when your desired unit is shown.

Digital display of the thermometer showing temperature in Celsius and Fahrenheit, indicating unit switching capability

Image 4.2: Switching between Celsius and Fahrenheit

Memory Function:

The HA500 thermometer can store up to 9 previous temperature readings. To access the memory, turn on the device and then press the 'START' button briefly multiple times. Each press will cycle through the stored readings, from the most recent to the oldest.

Digital display of the thermometer showing a number '9' indicating memory for 9 users or readings

Image 4.3: Memory for 9 readings

5. Maintenance and Cleaning

Proper maintenance ensures the longevity and accuracy of your thermometer:

  • Cleaning the Sensor: Gently wipe the sensor lens with a cotton swab or soft cloth lightly moistened with alcohol. Allow it to dry completely before use.
  • Cleaning the Device Body: Use a soft, dry cloth to clean the main body of the thermometer. Do not use abrasive cleaners or immerse the device in water.
  • Storage: Store the thermometer in its protective case in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Battery Replacement: Replace the battery promptly when the low battery indicator appears. Remove the battery if the device will not be used for an extended period.

6. Troubleshooting

If you encounter issues with your Rossmax HA500 thermometer, refer to the table below:

ProblemPossible CauseSolution
Device does not turn onDead or incorrectly installed batteryReplace battery, ensuring correct polarity.
Inaccurate or inconsistent readingsSensor dirty; incorrect measurement distance; external factors (drafts, sweat); device not acclimatized.Clean sensor; ensure 5cm distance; measure in a stable environment; allow device to stabilize at room temperature for 30 minutes. Take multiple readings for confirmation.
Display shows 'Lo' or 'Hi'Temperature is outside the measurable range.Ensure measurement is taken on a human body. If 'Lo' appears for body temperature, it indicates a very low temperature. If 'Hi' appears, it indicates a very high temperature.
Fever alarm sounds frequentlyActual high temperature; device malfunction.Confirm reading with another reliable thermometer. If readings are consistently high, seek medical advice. If device seems faulty, contact support.

If the problem persists after attempting these solutions, please contact Rossmax customer support.

7. Specifications

SpecificationDetail
Model NumberHA500 (also referred to as TH500)
Measurement TypeNon-Contact Infrared
Measurement SiteTemple / Forehead
Measurement DistanceWithin 5 cm (2 inches)
Measurement TimeApproximately 1 second
Temperature UnitsCelsius (°C) / Fahrenheit (°F) switchable
Memory9 readings
Power Source1 x LR44 Battery
Item Weight90 g
Product Dimensions (LxWxH)83.3 x 41.4 x 14.2 cm (Note: This dimension seems unusually large for a thermometer and may refer to packaging or a different product. Please refer to product packaging for exact device dimensions.)
Country of OriginChina

8. Warranty and Support

Rossmax products are manufactured to high-quality standards. This product typically comes with a standard manufacturer's warranty against defects in materials and workmanship. For specific warranty details, including duration and coverage, please refer to the warranty card included with your product or contact Rossmax customer service.

An optional 1-year extended warranty may be available for purchase separately. For technical support, service, or warranty claims, please contact your local Rossmax distributor or visit the official Rossmax website for contact information.

Manufacturer: MDF Instruments Direct, Inc. 5304 Derry Ave, Unit L, Agoura Hills, CA 91301, USA

Contact: cs@newnik.com, 9972528266

© 2025 Rossmax. All rights reserved. Information in this manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.