Introduction

The SFA Sanibroyeur Pro Up is a high-performance macerating pump designed for efficient wastewater evacuation from a toilet and a washbasin. This unit allows for the installation of sanitary facilities in locations where traditional gravity drainage is not feasible. Its compact design and silent operation make it an ideal solution for discreet integration into various environments. This manual provides essential information for the safe and correct installation, operation, and maintenance of your Sanibroyeur Pro Up.

SFA Sanibroyeur Pro Up Macerating Pump

Image: SFA Sanibroyeur Pro Up Macerating Pump, showing its compact white casing and connection points.

Safety Instructions

  • Always disconnect the power supply before any installation, maintenance, or repair work.
  • Ensure the electrical installation complies with local standards and regulations.
  • The appliance must be earthed.
  • Do not dispose of foreign objects (cotton, wipes, sanitary products, etc.) into the toilet connected to the macerator, as this can cause blockages and damage the unit.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

Setup and Installation

The Sanibroyeur Pro Up is designed for installation behind a WC with a horizontal outlet, and can also connect to a washbasin.

  1. Placement: Position the macerator directly behind the toilet. Ensure sufficient space for connections and future maintenance.
  2. Wastewater Connections: Connect the toilet outlet to the macerator's inlet. The unit is designed to handle wastewater from a toilet and one washbasin. Ensure all connections are sealed properly to prevent leaks. The evacuation pipe diameter should be between 22 mm and 32 mm.
  3. Discharge Pipe: Connect the macerator's discharge outlet to the main drainage system. The unit can pump wastewater up to 5 meters vertically and 100 meters horizontally. Ensure the discharge pipe has a continuous slope to prevent standing water.
  4. Electrical Connection: Connect the 400W motor to a dedicated 220/240V electrical supply. Ensure the circuit is protected by a residual current device (RCD) and complies with all local electrical codes.
  5. Testing: After installation, perform a test run by flushing the toilet and running water in the washbasin to check for proper operation and absence of leaks.
SFA Sanibroyeur Pro Up installed behind a toilet

Image: Illustration of the SFA Sanibroyeur Pro Up discreetly installed behind a toilet, showing its integration into a bathroom setting.

Operating Instructions

The SFA Sanibroyeur Pro Up operates automatically. When wastewater enters the unit, a pressure switch activates the motor, which then macerates the waste and pumps it through the discharge pipe.

  • Automatic Activation: The unit will automatically start when the water level inside rises, indicating waste entry.
  • Silent Operation: The Sanibroyeur Pro Up is designed for quiet operation, with a maximum noise level of 46 dB.
  • Power: The 400W motor ensures efficient maceration and powerful discharge of wastewater.
  • Usage: Use the connected toilet and washbasin as normal. Avoid flushing anything other than human waste and toilet paper.

Maintenance

Regular maintenance ensures the longevity and optimal performance of your Sanibroyeur Pro Up.

  • Cleaning: Periodically clean the unit using a non-corrosive, macerator-safe cleaning product. Follow the cleaner's instructions.
  • Basket Access: The Sanibroyeur Pro Up features direct access to the macerating basket, allowing for easy maintenance without requiring complete disassembly of the unit.
  • Inspection: Regularly inspect connections for any signs of leaks or wear.
  • Professional Service: For any complex issues or internal repairs, contact a qualified technician or SFA customer service.

Troubleshooting

If you encounter issues with your Sanibroyeur Pro Up, consider the following common troubleshooting steps:

  • Unit Not Starting:
    • Check if the unit is properly plugged into a live electrical outlet.
    • Verify the circuit breaker has not tripped.
    • Ensure no foreign objects are blocking the macerator blades. Disconnect power before checking.
  • Unit Running Continuously:
    • This often indicates a foreign object is lodged in the macerator, preventing the pressure switch from resetting. Disconnect power and inspect the basket.
    • Check for leaks in the toilet or washbasin that might be continuously filling the unit.
  • Unusual Noise or Vibration:
    • Disconnect power immediately. A foreign object may be caught in the macerator blades.
    • Ensure the unit is securely installed and not vibrating against walls or pipes.
  • Leaks:
    • Check all plumbing connections for tightness.
    • Inspect seals and gaskets for damage.

If these steps do not resolve the issue, please contact SFA customer support or a qualified plumber.

Specifications

FeatureDetail
Model NameSanibroyeur Pro Up
Item Model NumberST3STD
ManufacturerSFA
Product Dimensions (L x W x H)33.9 x 22.2 x 32.3 cm (13.35 x 8.74 x 12.72 inches)
Item Weight5.5 Kilograms (12.13 lbs)
ColorWhite
MaterialStainless Steel
Power SourceCorded Electric
Voltage220 Volts
Power400 Watts
Maximum Lift Height5 Meters (16.4 feet)
Maximum Horizontal Discharge100 Meters (328 feet)
Noise Level46 dB max
Pipe Diameter for Evacuation22 to 32 mm
Included ComponentsConnection accessories, Instruction manual, Sanibroyeur Pro
Country of OriginFrance
Technical drawing with dimensions of SFA Sanibroyeur Pro Up

Image: Technical drawing illustrating the dimensions and connection points of the SFA Sanibroyeur Pro Up.

Warranty and Support

The SFA Sanibroyeur Pro Up is manufactured with high-quality materials and benefits from the "Origine France Garantie" label, ensuring its French origin and quality craftsmanship.

  • Warranty: This product comes with a 5-year warranty from the date of purchase. Please retain your proof of purchase for warranty claims.
  • Support: For technical assistance, spare parts, or warranty service, please contact SFA customer support. Refer to the contact information provided with your product packaging or visit the official SFA website.

Related Documents - Sanibroyeur Pro Up (ST3STD)

PreviewSFA Sanibest Pro B85 Macerator Pump Installation and Technical Guide
Detailed installation instructions, parts list, diagrams, and technical specifications for the SFA Sanibest Pro B85 macerator pump, designed for domestic wastewater disposal. Includes company contact information and service helplines.
PreviewSFA Special Sanibroyeur Descaling Agent - Safety Data Sheet
Material Safety Data Sheet for SFA Special Sanibroyeur Descaling Agent, providing information on identification, hazards, composition, first aid, handling, storage, and regulatory information.
PreviewSanibroyeur Plus Sani 3 - Manuel d'installation et d'utilisation
Manuel d'installation et d'utilisation pour le Sanibroyeur Plus Sani 3 de SFA. Ce guide fournit des instructions détaillées pour l'installation, l'utilisation et la maintenance de votre pompe de relevage.
PreviewSFA SANIBEST® PRO B85 Installation and Maintenance Manual
This document provides comprehensive installation, operation, and maintenance instructions for the SFA SANIBEST® PRO B85 macerator pump. It covers safety precautions, applications, installation steps, electrical connections, troubleshooting, and warranty information.
PreviewSFA Sanifloor+ 1 & 2 Installation Guide and Technical Specifications
Comprehensive installation guide and technical details for SFA Sanifloor+ 1 and Sanifloor+ 2 shower pumps and drainage systems. Includes parts list, step-by-step instructions, dimensions, and service contact information.
PreviewSFA SANIPRO XR Macerator Pump: Installation, Operation & Troubleshooting Guide
Comprehensive guide for the SFA SANIPRO XR macerator pump, covering installation, applications, electrical connections, commissioning, maintenance, troubleshooting, and warranty. Includes technical specifications and multilingual instructions.