OSRAM 1131621

OSRAM QTP8 1x36/230-240 T8 Fluorescent Ballast Instruction Manual

Model: QTP8 1x36/230-240 | Part Number: 1131621

1. Introduction

This instruction manual provides essential information for the safe and efficient installation, operation, and maintenance of the OSRAM QTP8 1x36/230-240 T8 Fluorescent Ballast. Please read this manual thoroughly before proceeding with installation or use. Retain this manual for future reference.

2. Safety Information

WARNING: Risk of electric shock. Installation and servicing must be performed by a qualified electrician in accordance with all applicable national and local electrical codes and regulations.

  • Always disconnect power at the circuit breaker or fuse box before installing, servicing, or removing the ballast.
  • Ensure proper grounding to prevent electric shock.
  • Do not operate the ballast with damaged wiring or if the casing is compromised.
  • Verify that the input voltage and lamp wattage match the ballast specifications.
  • This ballast is designed for indoor use only.

3. Product Overview

The OSRAM QTP8 1x36/230-240 is an electronic fluorescent ballast designed to power one 36-watt T8 fluorescent lamp. It provides efficient and reliable operation, ensuring instant start and stable light output for compatible fluorescent lighting fixtures. The ballast operates on a 230-240 volt AC supply.

OSRAM QTP8 1x36/230-240 Fluorescent Ballast
Figure 1: OSRAM QTP8 1x36/230-240 Fluorescent Ballast. This image shows the rectangular ballast unit with wiring terminals at both ends and product labels detailing specifications and certifications.

4. Installation

Follow these steps for proper installation of the ballast:

  1. Power Disconnection: Ensure the main power supply to the fixture is turned off at the circuit breaker before beginning any installation work.
  2. Mounting: Securely mount the ballast within the lighting fixture using appropriate fasteners. Ensure adequate ventilation around the ballast.
  3. Wiring Connections: Refer to the wiring diagram printed on the ballast label and the general guidelines below. Use appropriate wire gauges for all connections.
    • Input Power (230-240V AC): Connect the Live (L) and Neutral (N) wires from the main power supply to the corresponding input terminals on the ballast.
    • Lamp Connections: Connect the lamp wires to the ballast output terminals (typically labeled 21, 22, 23, 24) as indicated by the wiring diagram for a single T8 fluorescent lamp. Ensure all connections are firm and secure.
  4. Verification: Double-check all wiring connections for correctness and security. Ensure no bare wires are exposed.
  5. Restore Power: Once installation is complete and verified, restore power to the fixture.

5. Operating Instructions

The OSRAM QTP8 1x36/230-240 T8 Fluorescent Ballast is designed for automatic operation. Once properly installed and connected to a compatible 36W T8 fluorescent lamp and power supply, the lamp will illuminate instantly upon activation of the power switch. The electronic design ensures flicker-free starting and stable light output.

6. Maintenance

This ballast contains no user-serviceable parts. Regular maintenance is limited to:

  • Cleaning: Periodically clean the exterior of the ballast and fixture to prevent dust accumulation, which can affect heat dissipation. Ensure power is disconnected before cleaning.
  • Inspection: Annually inspect wiring for signs of wear, damage, or loose connections. Replace any damaged components immediately.
  • Lamp Replacement: Replace fluorescent lamps with compatible 36W T8 lamps when they reach the end of their life or show signs of degradation.

7. Troubleshooting

If the lamp fails to operate correctly, perform the following checks:

  • No Light:
    • Verify that the power supply to the fixture is active.
    • Check that the fluorescent lamp is correctly seated and not faulty. Try replacing the lamp with a known good one.
    • Inspect all wiring connections for looseness or damage.
  • Flickering Lamp:
    • Ensure the lamp is fully inserted into its sockets.
    • Replace the lamp if it is old or showing signs of end-of-life flickering.
    • Verify stable input voltage.
  • Ballast Overheating:
    • Ensure adequate ventilation around the ballast.
    • Confirm the correct lamp type and wattage are being used.

If issues persist after performing these checks, contact a qualified electrician or OSRAM customer support.

8. Specifications

FeatureSpecification
BrandOSRAM
Model Number1131621
Part Number131621
Light TypeFluorescent
Number of Lamps1
Compatible Bulb TypeT8
Wattage (per lamp)36 Watts
Input Voltage230-240 Volts AC
Dimensions (W x H)1.18" x 14.17"
Item Weight3.52 ounces (0.22 Pounds)
MaterialGlass (referring to lamp compatibility)
Indoor/Outdoor UsageIndoor
Power SourceCorded Electric

9. Warranty and Support

This OSRAM product is covered by the manufacturer's standard warranty. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or visit the official OSRAM website. For technical assistance, troubleshooting, or warranty claims, please contact OSRAM customer support directly.

OSRAM Official Website: www.osram.com

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.