Kimberly-Clark KCC09507

Kimberly-Clark 09507 in-Sight JRT Jr. Tissue Dispenser Instruction Manual

Model: KCC09507

1. Introduction

This manual provides comprehensive instructions for the installation, operation, and maintenance of your Kimberly-Clark 09507 in-Sight JRT Jr. Tissue Dispenser. Please read this manual thoroughly before use to ensure proper function and longevity of the product. This dispenser is designed for use with JRT Jr. (Jumbo Roll Tissue Junior) rolls, providing a reliable and efficient solution for high-traffic restrooms.

Kimberly-Clark 09507 in-Sight JRT Jr. Tissue Dispenser, Trans Smoke color, mounted on a wall.

Image 1.1: Kimberly-Clark 09507 in-Sight JRT Jr. Tissue Dispenser. This image shows the dispenser's translucent smoke-colored cover, allowing visibility of the tissue roll inside. It is designed for wall mounting.

2. Safety Information

Please observe the following safety precautions:

  • Ensure the dispenser is securely mounted to a stable wall surface to prevent falling.
  • Do not overload the dispenser with incorrect tissue roll sizes.
  • Keep hands and fingers clear of moving parts during loading and operation.
  • Use only recommended cleaning agents to avoid damage to the dispenser material.
  • This product is intended for commercial or institutional use.

3. Setup and Installation

3.1 Package Contents

Verify that all components are present before beginning installation:

  • Kimberly-Clark 09507 in-Sight JRT Jr. Tissue Dispenser (1 unit)
  • Mounting hardware (screws and anchors)
  • Dispenser key (for opening and locking)

3.2 Mounting Instructions

The dispenser is designed for screw-in installation.

  1. Select Location: Choose a suitable wall location, ensuring it is at an appropriate height and clear of obstructions.
  2. Mark Drilling Points: Hold the dispenser against the wall at the desired mounting height. Use a pencil to mark the locations for the mounting screws through the pre-drilled holes on the back plate of the dispenser.
  3. Drill Holes: Using an appropriate drill bit for your wall type (e.g., masonry, drywall), drill pilot holes at the marked locations. If installing into drywall, insert the provided wall anchors.
  4. Secure Dispenser: Align the dispenser with the drilled holes. Insert the screws through the dispenser's mounting holes and into the wall anchors or studs. Tighten the screws until the dispenser is firmly secured to the wall. Do not overtighten.
  5. Test Stability: Gently pull on the dispenser to ensure it is securely mounted and does not wobble.

3.3 Loading Tissue Rolls

  1. Open Dispenser: Insert the provided key into the lock mechanism located on the top or side of the dispenser. Turn the key to unlock and open the front cover.
  2. Insert Main Roll: Place a new JRT Jr. tissue roll onto the main spindle inside the dispenser. Ensure the tissue feeds from the bottom of the roll.
  3. Thread Tissue: Pull the leading edge of the tissue paper down through the dispensing slot at the bottom of the dispenser.
  4. Load Stub Roll (if applicable): If a stub roll (partially used roll) is present, place it on the auxiliary stub roll holder. The dispenser is designed to utilize the stub roll completely before switching to the new main roll.
  5. Close and Lock: Close the front cover of the dispenser firmly until it clicks shut. Turn the key to lock the dispenser. Remove the key.

4. Operating Instructions

4.1 Dispensing Tissue

To dispense tissue, simply pull the exposed end of the tissue paper downwards from the dispensing slot. The dispenser is designed for smooth, single-sheet or controlled dispensing, depending on the tissue type used.

4.2 Monitoring Tissue Levels (in-Sight Feature)

The "in-Sight" feature refers to the translucent smoke-colored cover of the dispenser. This design allows maintenance staff to visually monitor the remaining tissue level without needing to open the dispenser. This helps in efficient refilling and prevents unexpected run-outs.

5. Maintenance

5.1 Cleaning

Regular cleaning will help maintain the appearance and hygiene of your dispenser.

  • Wipe the exterior surfaces with a soft, damp cloth and a mild, non-abrasive cleaner.
  • Avoid using harsh chemicals, abrasive pads, or solvents, as these can damage the plastic finish.
  • Ensure the dispenser is dry after cleaning.

5.2 Refilling

Refill the dispenser as described in Section 3.3 "Loading Tissue Rolls" when the main roll is depleted or when the stub roll is in use and a new main roll is required.

6. Troubleshooting

ProblemPossible CauseSolution
Tissue not dispensing smoothly.
  • Incorrect tissue roll size.
  • Tissue roll jammed or misaligned.
  • Dispenser mechanism obstructed.
  • Ensure JRT Jr. rolls are used.
  • Open dispenser, re-align roll, and re-thread tissue.
  • Check for debris or foreign objects inside the dispenser.
Dispenser cover will not close or lock.
  • Tissue roll not seated correctly.
  • Obstruction preventing closure.
  • Lock mechanism jammed.
  • Ensure tissue roll is fully seated on the spindle.
  • Check for any objects blocking the cover's path.
  • Apply a small amount of lubricant to the lock mechanism if it feels stiff.
Dispenser feels loose on the wall.
  • Mounting screws are loose.
  • Wall anchors are failing.
  • Tighten mounting screws.
  • If anchors are failing, consider relocating the dispenser or using stronger anchors.

7. Specifications

FeatureDetail
Model NumberKCC09507
BrandKimberly-Clark
MaterialPlastic
ColorTrans Smoke (Translucent Smoke)
Dimensions (W x D x H)Approximately 13 22/25" x 5 3/4" x 16" (35.3cm x 14.6cm x 40.6cm)
Installation TypeScrew-In (Wall Mount)
Compatible TissueJRT Jr. (Jumbo Roll Tissue Junior)
WeightApproximately 4 Pounds (1.8 kg)

8. Warranty and Support

8.1 Product Warranty

Kimberly-Clark Professional products are manufactured to high-quality standards. For specific warranty details regarding your 09507 in-Sight JRT Jr. Tissue Dispenser, please refer to the warranty information provided at the time of purchase or visit the official Kimberly-Clark Professional website. Keep your proof of purchase for warranty claims.

8.2 Customer Support

If you encounter any issues or have questions not covered in this manual, please contact Kimberly-Clark Professional customer support. Contact information can typically be found on the product packaging or the official Kimberly-Clark Professional website.

Website: www.kcprofessional.com

© 2024 Kimberly-Clark. All rights reserved.

This manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.