This manual provides detailed instructions for the installation, operation, and maintenance of your Phylrich K3240_015 Versailles Two Handle Shower Set. Please read all instructions carefully before beginning installation or use to ensure proper function and longevity of your product. Retain this manual for future reference.

2. Safety Information

  • Always turn off the main water supply before installing or servicing the shower set.
  • Wear appropriate personal protective equipment, such as safety glasses and gloves, during installation.
  • If you are unsure about any part of the installation process, consult a qualified plumber.
  • Ensure all connections are secure to prevent leaks.
  • Comply with all local plumbing and building codes.

3. Package Contents

Carefully unpack your new shower set and ensure all components are present and undamaged. If any parts are missing or damaged, do not proceed with installation and contact Phylrich customer service.

  • Showerhead with arm
  • Two (2) Handles (Green Onyx)
  • Valve trim components
  • Mounting hardware
Phylrich K3240_015 Versailles Two Handle Shower Set components including showerhead and two handles.

Image: Components of the Phylrich K3240_015 Versailles Two Handle Shower Set, showing the decorative showerhead and two ornate handles with green onyx accents.

4. Setup and Installation

Professional installation is recommended for this product. Ensure you have all necessary tools and materials before beginning.

4.1 Pre-Installation Steps

  1. Turn off the main water supply to the bathroom.
  2. Clear the work area and ensure adequate lighting.
  3. Review your existing plumbing setup to ensure compatibility.

4.2 Valve Installation (Rough-in)

Install the shower valve body according to the manufacturer's instructions provided with the valve (valve sold separately). Ensure the valve is properly secured and plumb within the wall.

4.3 Trim Installation

  1. Install the escutcheon plate over the valve body, securing it to the wall.
  2. Attach the two handles to their respective hot and cold valve stems. Ensure they are oriented correctly for proper operation.
  3. Secure the handles with the provided set screws.

4.4 Showerhead Installation

  1. Apply plumber's tape to the threaded end of the shower arm.
  2. Thread the shower arm into the wall fitting, tightening securely.
  3. Thread the showerhead onto the shower arm, ensuring a tight seal. Do not overtighten.

4.5 Post-Installation

  1. Slowly turn on the main water supply.
  2. Check all connections for leaks. Tighten any leaking connections as necessary.
  3. Test the shower for proper water flow and temperature control.

5. Operating Instructions

The Phylrich K3240_015 Versailles Shower Set features two handles for precise control over water temperature and flow.

  • Cold Water Handle: Turn the handle counter-clockwise to increase cold water flow.
  • Hot Water Handle: Turn the handle counter-clockwise to increase hot water flow.
  • Adjust both handles simultaneously to achieve your desired water temperature and flow rate.
  • To turn off the water, rotate both handles clockwise until the water flow stops completely.

6. Maintenance

Regular cleaning and maintenance will help preserve the finish and functionality of your shower set.

6.1 Cleaning the Finish

  • Clean the shower set regularly with a soft, damp cloth.
  • Avoid using abrasive cleaners, harsh chemicals, or scouring pads, as these can damage the finish.
  • For stubborn spots, use a mild soap solution and rinse thoroughly with clean water, then dry with a soft cloth.

6.2 Showerhead Maintenance

  • Periodically inspect the showerhead nozzles for mineral buildup.
  • If mineral deposits are present, gently rub the rubber nozzles to dislodge them. For more severe buildup, the showerhead may need to be removed and soaked in a vinegar solution.

7. Troubleshooting

Refer to the following table for common issues and their solutions.

ProblemPossible CauseSolution
Low Water PressurePartially closed shut-off valves; clogged showerhead; mineral buildup in pipes.Ensure shut-off valves are fully open. Clean showerhead nozzles. Consult a plumber for pipe issues.
Leaking from ShowerheadLoose connection; damaged washer/gasket.Tighten showerhead connection. Replace washer/gasket if damaged.
Leaking from Handles/ValveLoose packing nut; worn O-rings or cartridges.Tighten packing nut. Replace O-rings or cartridges as needed (consult a plumber).
Difficulty Adjusting TemperatureValve cartridge issue; unbalanced water pressure.Inspect or replace valve cartridge. Check water pressure balance.

8. Specifications

  • Brand: Phylrich
  • Model Number: K3240/015
  • Number of Handles: 2
  • Finish: Satin Nickel (as per feature bullets, though product title mentions Green Onyx Handle, this refers to the handle material/color)
  • UPC: 883908281258
  • First Available Date: September 8, 2010

9. Warranty Information

For specific warranty details regarding your Phylrich K3240_015 Versailles Two Handle Shower Set, please refer to the warranty documentation included with your purchase or visit the official Phylrich website. Warranty terms and conditions may vary.

10. Customer Support

If you require further assistance, have questions about installation, or need to order replacement parts, please contact Phylrich customer support directly. Contact information can typically be found on the manufacturer's website or in your product packaging.

Related Documents - K3240/015

Preview Phylrich Jamestown Series Single Handle Widespread Faucet Installation Guide
Comprehensive installation instructions for the Phylrich Jamestown Series single handle widespread faucet with high spout and lever handle. Covers spout, valve, and drain assembly with detailed steps and textual descriptions of diagrams.
Preview Phylrich DFPHY & DFPHYID 1/2" Pressure Balance Valve Installation Instructions
Comprehensive installation guide for the Phylrich DFPHY and DFPHYID 1/2 inch pressure balance valve, covering general characteristics, valve specifications, rough-in dimensions, temperature settings, and maintenance procedures.
Preview Jamestown Series Wall Lavatory Set Installation Instructions
Detailed installation guide for the Phylrich Jamestown Series Wall Lavatory Set, including models 165-11 (Cross Handle) and 165-12 (Lever Handle). Covers spout, escutcheon, handle installation, trim adjustments, and cartridge replacement with torque specifications.
Preview Phylrich Jamestown Series Lavatory Faucet Installation Guide & Limited Warranty
Comprehensive installation instructions for the Phylrich Jamestown Series lavatory faucet with a dry tee flush mounted valve, including detailed steps, diagrams, and information on the limited lifetime warranty.
Preview Phylrich 1-124 Wall Mounted Bidet Installation Instructions
Comprehensive installation guide for the Phylrich 1-124 Wall Mounted Bidet, detailing valve specifications, parts breakdown, rough-in dimensions, installation procedures, and maintenance tips for optimal performance and longevity.
Preview Phylrich Transition Series Lavatory Faucet Installation Guide & Limited Warranty
Comprehensive installation instructions and limited warranty details for the Phylrich Transition Series lavatory faucet with a dry tee flush mounted valve, covering setup, drain assembly, and product coverage.