Introduction
This manual provides detailed instructions for the proper use and maintenance of your seca 869 Flat Scale with Cable Remote Display. Please read this manual thoroughly before operating the device to ensure accurate measurements and safe operation. The seca 869 is designed for precise weight measurement, featuring a remote display connected by a 6.5-foot cable, allowing flexible placement of the display unit.
Product Overview
The seca 869 is a versatile flat scale with a separate display unit. This design allows the weighing base to be placed on the floor while the display can be positioned on a desk or mounted on a wall for easy viewing. It includes various functions such as TARE, HOLD, and BMI calculation, making it suitable for diverse applications.

Image 1: The seca 869 Flat Scale with its remote display unit, showing the cable connection. The display is positioned above the weighing platform.

Image 2: Top-down view of the seca 869 scale, highlighting the textured weighing surface and the remote display unit placed beside it.
Setup
- Unpacking: Carefully remove all components from the packaging. Ensure all parts are present: the weighing platform, the remote display unit, and the connecting cable.
- Battery Installation: The seca 869 requires 4 AA batteries (included). Locate the battery compartment on the underside of the display unit. Open the compartment, insert the batteries according to the polarity indicators, and close the cover securely.
- Connecting the Display: Connect the cable from the weighing platform to the designated port on the remote display unit. Ensure the connection is firm. The cable is approximately 6.5 feet long, allowing for flexible placement.
- Placement of the Weighing Platform: Place the weighing platform on a firm, level surface. Uneven surfaces can affect measurement accuracy. The scale features a leveling base for stability.
- Placement of the Remote Display: Position the remote display unit on a stable surface, such as a desk, or mount it on a wall using appropriate hardware (not included). Ensure the display is easily visible for reading measurements.

Image 3: Side profile of the seca 869 weighing platform, showing its low height and stable feet, suitable for various surfaces.
Operating Instructions
- Power On/Off: Press the "Start" button to turn on the scale. The display will show "0.0" when ready for measurement. The scale features an automatic switch-off function to conserve battery life.
- Weighing: Step onto the center of the weighing platform. Stand still until the measurement stabilizes. The weight will be displayed on the remote unit.
- Units Switch-over (lbs/kg): Press the "kg to st" button to toggle between kilograms (kg) and pounds (lbs) or stones (st).
- TARE Function: The TARE function allows you to subtract the weight of an object (e.g., a blanket or an adult holding a child) to measure only the net weight.
- Place the object (or person holding a child) on the scale.
- Press the "Tare" button. The display will reset to "0.0".
- Now, place the item to be weighed (or the child) on the scale. The display will show its net weight.
- HOLD Function: The HOLD function keeps the measurement displayed even after the person steps off the scale. This is useful for recording readings.
- Weigh as usual.
- Press the "Hold" button while the weight is displayed. The reading will be held on the screen.
- Press "Hold" again or "Start" to clear the held reading.
- BMI Function: The Body Mass Index (BMI) function helps assess nutritional status.
- Enter the user's height using the appropriate buttons (refer to the display unit's specific height input method, usually indicated by arrows or a dedicated height button).
- Step onto the scale.
- Press the "BMI" button. The display will calculate and show the BMI value.

Image 4: Detailed view of the remote display unit, showing the LCD screen and control buttons for functions like Start, kg to st, Hold, Tare, and BMI.
Maintenance
- Cleaning: Clean the weighing platform and display unit with a damp cloth and a mild detergent. Do not use abrasive cleaners or immerse the unit in water.
- Storage: Store the scale in a dry place, away from extreme temperatures and direct sunlight.
- Battery Replacement: Replace batteries when the low battery indicator appears on the display. Always replace all batteries at the same time with new ones of the same type.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Scale does not turn on. | Dead or incorrectly installed batteries. | Check battery polarity. Replace batteries if necessary. |
| Inaccurate readings. | Scale on an uneven surface; movement during measurement; overloaded scale. | Place scale on a firm, level surface. Stand still during measurement. Ensure weight is within capacity (550 lbs / 250 kg). |
| Display shows "Err" or similar error message. | Overload; internal error. | Remove weight from scale. If error persists, remove batteries for 1 minute and reinsert. If problem continues, contact customer support. |
| Display is blank or dim. | Low batteries; loose cable connection. | Replace batteries. Check that the cable connecting the platform and display is securely plugged in. |
Specifications
- Model: seca 869
- Capacity: 550 lbs / 250 kg
- Graduation: 0.2 lbs / 100 g (up to 200 kg), 0.5 lbs / 200 g (above 200 kg)
- Functions: TARE, HOLD, BMI, lbs/kg switch-over, automatic switch-off
- Display Type: LCD, LED
- Power Source: 4 AA batteries (included)
- Product Dimensions: 11.3 x 11 x 2.4 inches (weighing platform)
- Product Weight: 9.9 Pounds
- Cable Length: 6.5 feet (connecting display to platform)
Warranty and Support
For warranty information and customer support, please refer to the documentation included with your product or visit the official seca website. Contact information for technical assistance can typically be found on the manufacturer's website or in the product packaging.
Legal Disclaimer: Statements regarding dietary supplements have not been evaluated by the FDA and are not intended to diagnose, treat, cure, or prevent any disease or health condition. This product is a medical device and should be used in accordance with its intended purpose.