Steelman 10150A
Steelman 16-inch Bend-A-Light Pro Automotive Inspection Light Instruction Manual
Model: 10150A
1. Introduction
The Steelman 16-inch Bend-A-Light Pro is a specialized automotive inspection light designed to provide illumination in confined and hard-to-reach areas. Its flexible gooseneck and compact bulb allow for precise light placement, making it an essential tool for detailed inspections.

Figure 1: Steelman Bend-A-Light Pro and its handle extension.
2. Product Features
- Flexible Gooseneck: Features a 9.5-inch flexible brass alloy gooseneck shaft for navigating obstacles and directing light precisely.
- Compact Bulb: Equipped with a 5/32-inch diameter bulb to access extremely cramped spaces.
- Extended Illumination: Provides up to four hours of continuous high-intensity incandescent light per battery change.
- Dual-Purpose Protective Cover: The included protective cover can also be used as a handle extension to lengthen the tool's reach.
- Batteries Included: Two AA batteries are supplied with the unit.

Figure 2: Close-up view of the flexible tip and bulb.
3. Setup
3.1 Battery Installation
- Unscrew the end cap of the light's main body.
- Insert two AA batteries, ensuring correct polarity (+/-) as indicated inside the battery compartment.
- Replace the end cap and screw it on securely.
3.2 Attaching the Handle Extension
The protective cover can be attached to the base of the light to extend its handle, providing additional reach. Align the open end of the extension tube with the base of the light and push it firmly into place.

Figure 3: Bend-A-Light Pro with the handle extension in place.
4. Operating Instructions
- Power On/Off: Press the button located on the end cap to turn the light on or off.
- Positioning the Light: Gently bend the flexible gooseneck shaft to direct the light to the desired inspection area. The shaft retains its shape once positioned.
- Accessing Tight Spaces: Utilize the slim 5/32-inch diameter bulb to illuminate areas where larger lights cannot reach.

Figure 4: Light in use for automotive inspection.
5. Maintenance
- Cleaning: Wipe the light's body and gooseneck with a clean, dry cloth. Avoid using abrasive cleaners or solvents.
- Battery Storage: If the light will not be used for an extended period, remove the AA batteries to prevent potential leakage and damage to the device.
- Bulb Replacement: Replacement bulbs are available. To replace, carefully unscrew the metal tip housing the bulb, remove the old bulb, and insert a new one. Ensure the new bulb is securely seated before reattaching the tip housing.
6. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Light does not turn on | Dead batteries, incorrect battery orientation, faulty switch, loose bulb. | Check battery orientation and replace batteries. Ensure the end cap is fully tightened. Check if the bulb is securely seated. |
| Light is dim | Low batteries, dirty bulb. | Replace batteries. Clean the bulb surface if visibly dirty. |
| Flexible shaft does not hold position | Excessive force or repeated bending beyond design limits. | Avoid over-bending the shaft. If damaged, contact Steelman support for potential replacement parts. |
7. Specifications
- Model: 10150A
- Overall Length: 16 inches
- Flexible Gooseneck Length: 9.5 inches
- Bulb Diameter: 5/32 inches
- Power Source: 2 AA batteries (included)
- Approximate Battery Life: 4 hours continuous use
- Item Weight: 5.3 ounces
- Product Dimensions: 17.25 x 4 x 1 inches
- Color: Black
- Material: Plastic, Brass Alloy
8. Warranty and Support
For warranty information, replacement parts, or technical support, please contact Steelman customer service. Refer to the official Steelman website or product packaging for the most current contact details.
You can visit the Steelman Store on Amazon for additional product information and support resources.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.