1. Introduction and Product Overview
This manual provides essential information for the safe and effective use of the Mersen ATQ1 Time Delay Midget Fuse. The ATQ1 is a 500V, 1A fuse designed for circuit protection, featuring a time-delay characteristic to handle temporary overcurrents without nuisance tripping.

Figure 1: Mersen ATQ1 Time Delay Midget Fuse. A close-up view of the Mersen ATQ1 time delay midget fuse, showing its cylindrical ceramic body with metal end caps. The fuse is marked with 'Amp-Trap' and 'ATQ' branding in orange text.
The Mersen ATQ1 fuse is part of the Amp-Trap® brand, known for its reliable circuit protection solutions. It is suitable for applications requiring a 1 Ampere current rating and a 500 Vac voltage rating, with an interrupting rating of 10 Kiloampere.
2. Safety Information
WARNING: Electrical work should only be performed by qualified personnel. Always disconnect power before installing, removing, or inspecting fuses to prevent electric shock or equipment damage.
- Ensure the replacement fuse matches the voltage, current, and interrupting rating of the original fuse.
- Do not use a fuse with a higher current rating than specified for the circuit.
- Wear appropriate personal protective equipment (PPE), such as insulated gloves and safety glasses.
- This product may expose you to chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.
3. Product Features
The Mersen ATQ1 fuse offers the following key features:
- Time Delay Characteristics: Provides a 12-second time delay at 200% rated load, preventing nuisance tripping from temporary overcurrents.
- Voltage Rating: Rated for 500 Vac.
- Current Rating: 1 Ampere.
- Interrupting Rating: 10 Kiloampere, ensuring safe interruption of high fault currents.
- Terminal Type: Ferrule terminal for secure connections.
- Approvals: UL 248-14 and CSA C22.2 compliant.
4. Specifications
| Specification | Value |
|---|---|
| Brand | Mersen |
| Model Number | ATQ1 |
| Voltage Rating | 500 Volts AC |
| Current Rating | 1 Ampere |
| Interrupting Rating | 10 Kiloampere |
| Time Delay | 12 seconds (at 200% rated load) |
| Terminal Type | Ferrule |
| Diameter | 13/32 Inch |
| Length | 1-1/2 Inch |
| Approvals | UL 248-14, CSA C22.2 |
| Item Weight | 0.16 ounces |
| Package Dimensions | 2.1 x 1.7 x 0.9 inches |
5. Installation and Setup
Proper installation is crucial for the safe and effective operation of the fuse. Always follow local electrical codes and safety guidelines.
- Disconnect Power: Before beginning any work, ensure that the main power supply to the circuit is completely disconnected and locked out. Verify with a voltage tester.
- Identify Fuse Holder: Locate the fuse holder where the ATQ1 fuse is to be installed or replaced.
- Remove Old Fuse (if applicable): Carefully remove the existing fuse from its holder. Use a fuse puller if necessary.
- Inspect Fuse Holder: Check the fuse holder for any signs of damage, corrosion, or loose connections. Address any issues before proceeding.
- Insert New Fuse: Insert the Mersen ATQ1 fuse into the fuse holder, ensuring it is seated firmly and correctly. The ferrule terminals should make good contact.
- Restore Power: Once the fuse is securely in place and all connections are verified, restore power to the circuit.
- Test Circuit: Verify that the circuit is functioning as expected.
Important: Never bypass a fuse or replace it with a fuse of incorrect rating. This can lead to severe damage to equipment, fire, or personal injury.
6. Operation
The Mersen ATQ1 is a time-delay fuse, meaning it is designed to allow temporary overcurrents, such as those caused by motor starting or transformer inrush, to pass without opening the circuit. However, it will open and interrupt the circuit if a sustained overcurrent or short-circuit condition occurs, protecting the electrical components and wiring from damage.
When the fuse operates (blows), it indicates an electrical fault or overload condition in the protected circuit. It is crucial to identify and rectify the cause of the fault before replacing the fuse.
7. Maintenance
Fuses are generally maintenance-free components. The primary maintenance action involves replacing a blown fuse. Regular inspection of fuse holders and connections for signs of wear, corrosion, or overheating is recommended as part of a broader electrical system maintenance schedule.
Fuse Replacement Procedure:
- Safety First: Always disconnect and lock out the power supply to the circuit before attempting to replace a fuse.
- Identify Blown Fuse: A blown fuse may show visible signs of damage (e.g., discolored glass, broken filament if visible), or it may need to be tested with a multimeter for continuity.
- Match Replacement: Ensure the replacement fuse is an exact match for the original in terms of brand (Mersen), model (ATQ1), voltage (500V), and current (1A) ratings.
- Install New Fuse: Follow the installation steps outlined in Section 5.
- Restore Power: Re-energize the circuit and verify operation.
8. Troubleshooting
If a Mersen ATQ1 fuse blows, it indicates an issue within the protected circuit. Here are common troubleshooting steps:
- Repeated Fuse Blowing: If a new fuse blows immediately or shortly after installation, it strongly suggests a persistent overload or a short circuit in the system. Do not continue replacing fuses without investigating the root cause.
- Identify Overload: Check for too many devices connected to the circuit, faulty motors, or other equipment drawing excessive current.
- Check for Short Circuits: Inspect wiring for damaged insulation, pinched wires, or loose connections that could be causing a direct path between live and neutral/ground conductors.
- Faulty Equipment: Disconnect individual components or appliances from the circuit one by one to isolate the faulty device.
- Incorrect Fuse Rating: Double-check that the installed fuse has the correct voltage and current ratings for the circuit it is protecting. Using an underrated fuse will lead to frequent blowing.
If you are unable to identify and resolve the issue, consult a qualified electrician.
9. Warranty and Support
For specific warranty information regarding Mersen products, please refer to the official Mersen website or contact their customer support directly. Fuses are consumable components designed to sacrifice themselves to protect circuits, and as such, their warranty typically covers manufacturing defects rather than normal operation (blowing due to fault conditions).
For technical assistance or further inquiries, please visit the official Mersen website or contact their authorized distributors.