1. Product Overview
The Mersen ATM12 is a fast-acting midget fuse designed for overcurrent protection in various electrical circuits. This fuse is rated for 600 Vac/500 Vdc and has a 12 Ampere current rating, with an interrupting rating of 100 Kiloampere. It features a ferrule terminal design and complies with UL 198L, UL 248-14, and CSA C22.2 standards. The ATM12 fuse is part of the Amp-Trap® brand, providing reliable circuit protection.

Image 1.1: A Mersen ATM12 600V 12A Midget Fuse. This image displays the cylindrical body of the fuse with metallic end caps, indicating its ferrule terminal design.
2. Safety Information
WARNING: Risk of electric shock or burn. Always disconnect power before installing, removing, or servicing fuses. Only qualified personnel should perform electrical work.
- Ensure the power supply to the circuit is completely disconnected and locked out before handling fuses.
- Verify the voltage and current ratings of the replacement fuse match the original fuse and circuit requirements.
- Do not use fuses that show signs of damage or tampering.
- Wear appropriate personal protective equipment (PPE), such as insulated gloves and safety glasses, when working with electrical circuits.
- Never bypass a fuse or use a fuse with a higher rating than specified, as this can lead to equipment damage or fire.
3. Product Features
- Fast Acting Characteristics: Designed to open quickly under overcurrent conditions, protecting sensitive components.
- Voltage Rating: Suitable for use in 600 Vac and 500 Vdc circuits.
- Current Rating: 12 Ampere.
- Interrupting Rating: 100 Kiloampere, indicating its ability to safely interrupt high fault currents.
- Terminal Type: Ferrule Terminal, ensuring secure connection in fuse holders.
- Approvals: UL 198L, UL 248-14, CSA C22.2 compliant.
4. Setup and Installation
4.1 Before Installation
- Confirm the circuit's voltage and current requirements match the ATM12 fuse specifications.
- Ensure the fuse holder is clean and free from debris or corrosion.
- Verify that the fuse holder is designed for midget fuses (13/32 inch diameter, 1-1/2 inch length).
4.2 Installation Steps
- Disconnect Power: Turn off and lock out all power to the circuit where the fuse will be installed or replaced. Use a voltage tester to confirm the circuit is de-energized.
- Remove Old Fuse (if applicable): Carefully remove the blown or old fuse from its holder.
- Insert New Fuse: Insert the Mersen ATM12 fuse into the fuse holder. Ensure both ferrule ends make firm contact with the holder's terminals.
- Secure Fuse: If the fuse holder has a cap or cover, secure it properly.
- Restore Power: Once the fuse is securely installed and all safety precautions are observed, restore power to the circuit.
5. Operating Instructions
The Mersen ATM12 midget fuse is a passive overcurrent protection device. It operates automatically by melting its internal element when the current flowing through it exceeds its rated capacity for a specified duration. This action opens the circuit, preventing damage to electrical components or wiring due to overloads or short circuits. No user interaction is required for its operation.
6. Maintenance
Fuses generally require minimal maintenance. However, periodic inspection is recommended:
- Visual Inspection: Periodically inspect fuses and fuse holders for signs of overheating, discoloration, or physical damage.
- Replacement: If a fuse blows, it must be replaced with an identical Mersen ATM12 fuse to maintain proper circuit protection. Do not attempt to repair a blown fuse.
- Cleaning: Ensure fuse holders are kept clean and free of dust or corrosive materials to maintain good electrical contact.
7. Troubleshooting
7.1 Fuse Blows Repeatedly
- Overload: The circuit may be drawing more current than its design capacity. Reduce the load on the circuit.
- Short Circuit: A direct short circuit could be present. Inspect wiring and connected devices for faults.
- Incorrect Fuse Rating: Ensure the ATM12 fuse is the correct rating for the application. Using an undersized fuse will lead to frequent blowing.
- Faulty Equipment: A connected device may be malfunctioning and drawing excessive current.
7.2 Fuse Does Not Blow (Circuit Malfunctions)
- This scenario is less common for a properly rated fuse but could indicate a problem with the fuse itself (e.g., manufacturing defect, though rare) or that the fault current is below the fuse's interrupting rating but still damaging.
- Ensure the fuse is correctly installed and making proper contact.
8. Specifications
| Brand | Mersen |
| Model Number | ATM12 |
| Voltage Rating | 600 Vac / 500 Vdc |
| Current Rating | 12 Amps |
| Interrupting Rating | 100 Kiloampere |
| Characteristics | Fast Acting |
| Terminal Type | Ferrule |
| Diameter | 13/32 Inch |
| Length | 1-1/2 Inch |
| Material | Copper |
| Approvals | UL 198L, UL 248-14, CSA C22.2 |
| Item Weight | 0.16 ounces |
| Manufacturer | Schaedler Yesco Distribution, Inc. |
9. Warranty and Support
Warranty information for Mersen products is typically provided by the authorized distributor or seller at the time of purchase. Please refer to your purchase documentation or contact your supplier for specific warranty terms and conditions.
For technical support or further inquiries regarding the Mersen ATM12 fuse, please contact Mersen directly or consult their official website for support resources and contact information.