Eberle 1472278

Eberle 1472278 Multifunction Relay (MSM-200) User Manual

Model: 1472278

1. Safety Instructions

Read these instructions carefully before installing or operating the device. Failure to follow these instructions may result in property damage, serious injury, or death.

  • Disconnect power to the circuit before performing any installation, maintenance, or troubleshooting.
  • Installation and wiring must be performed by qualified electrical personnel in accordance with all local and national electrical codes.
  • Do not operate the device if it appears damaged.
  • Ensure the device is used within its specified voltage and current ratings.
  • Protect the device from moisture, dust, and extreme temperatures.

2. Product Overview

The Eberle 1472278 (MSM-200) is a versatile multifunction time relay designed for various control applications. It supports multiple input voltages, making it suitable for diverse electrical systems. This device functions as a time relay, providing timed switching capabilities for connected loads.

Eberle 1472278 Multifunction Relay (MSM-200) product image

Image showing the front view of the Eberle 1472278 Multifunction Relay, highlighting its compact design and terminal connections.

3. Installation and Setup

3.1 Mounting

The relay is designed for mounting on a standard DIN rail within an electrical enclosure. Ensure adequate ventilation around the device to prevent overheating.

  1. Locate a suitable position on the DIN rail.
  2. Clip the relay onto the DIN rail until it securely locks into place.

3.2 Wiring

Refer to the wiring diagram provided on the device casing or in the detailed technical documentation. Ensure all connections are secure and correctly terminated.

  • Power Supply: Connect the appropriate voltage (24V AC, 110V AC, 230V AC, or 24V UC) to the designated power terminals. Observe correct polarity for DC connections.
  • Input/Control: Connect control signals to the input terminals as required by your application.
  • Output/Load: Connect the load to be controlled to the relay's output contacts. Ensure the load current does not exceed the relay's contact rating.

After wiring, double-check all connections for correctness and tightness before applying power.

4. Operating Instructions

The MSM-200 is a multifunction time relay. Specific operating modes and time settings are typically configured via rotary switches or dip switches on the device itself. Consult the markings on the relay for detailed configuration options.

  • Function Selection: Use the function selector switch (if present) to choose the desired timing mode (e.g., ON-delay, OFF-delay, flasher).
  • Time Range Selection: Set the appropriate time range using the dedicated switch.
  • Time Adjustment: Fine-tune the timing period within the selected range using the adjustment knob.
  • Indicators: Observe any LED indicators for power status, relay activation, and timing progress.

Once configured, apply power to the circuit. The relay will operate according to the selected function and time settings.

5. Maintenance

The Eberle 1472278 relay is designed for maintenance-free operation under normal conditions. However, periodic inspection is recommended.

  • Cleaning: Ensure the device is free from dust and debris. Disconnect power before cleaning. Use a soft, dry cloth. Do not use liquid cleaners.
  • Inspection: Periodically check wiring connections for tightness and inspect the device for any signs of physical damage or discoloration.
  • Environmental Conditions: Ensure the operating environment remains within the specified temperature and humidity limits.

6. Troubleshooting

If the relay does not function as expected, consider the following:

ProblemPossible CauseSolution
Relay not activatingNo power supply
Incorrect wiring
Incorrect function/time setting
Check power source and voltage
Verify all wiring connections
Review and adjust function/time settings
Incorrect timingIncorrect time range or adjustment
Unstable power supply
Re-adjust time range and fine-tuning
Ensure stable power supply
Load not switchingOverloaded contacts
Faulty load connection
Check load current against relay rating
Inspect load wiring and load functionality

If the problem persists after attempting these solutions, contact qualified technical support.

7. Specifications

ParameterValue
ManufacturerEberle Controls GmbH
Model Number1472278 (MSM-200)
Input Voltage24/110/230 V AC, 24 V UC
Power Consumption1 W
TypeMultifunction Time Relay
Package Dimensions8.1 x 5 x 5 cm
Weight132 g
Batteries RequiredNo

8. Warranty and Support

For information regarding warranty terms and conditions, please refer to the documentation provided with your purchase or contact Eberle Controls GmbH directly. Technical support can be obtained through the manufacturer's official channels.

Manufacturer: Eberle Controls GmbH

© 2024 Eberle Controls GmbH. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.