Packard PR380

Packard PR380 Fan Relay Instruction Manual

Model: PR380

1. Introduction

This manual provides comprehensive instructions for the safe installation, proper operation, and routine maintenance of the Packard PR380 Fan Relay. This electromechanical relay is designed for switching applications in heating, ventilation, and air conditioning (HVAC) systems, specifically for controlling fan motors and solenoids. Please read this manual thoroughly before installation or operation to ensure optimal performance and safety.

2. Safety Information

WARNING: Electrical Shock Hazard

  • Always disconnect power to the equipment before installing, servicing, or removing the relay. Failure to do so can result in serious injury or death.
  • Installation should only be performed by a qualified electrician or HVAC technician.
  • Ensure all wiring connections are secure and comply with local electrical codes.
  • Do not exceed the specified voltage and current ratings of the relay.
  • Wear appropriate personal protective equipment (PPE) when working with electrical systems.

3. Product Overview

The Packard PR380 is a robust fan relay featuring a 24 VAC coil voltage and Single-Pole, Single-Throw (SPST) Normally Open (NO) and Normally Closed (NC) contacts. It is commonly used as a replacement for Mars 90380 and RBM 90-380 relays.

Packard PR380 Fan Relay with 24 VAC coil and quick connect terminals

Image showing the Packard PR380 Fan Relay, highlighting its compact design and terminal layout for electrical connections.

Key Features:

  • Coil Voltage: 24 VAC
  • Contact Configuration: SPST Normally Open (NO) and Normally Closed (NC)
  • Terminals: 1/4-inch quick connect terminals for easy installation
  • Resistive Current Rating: 18 Amps
  • FLA/RLA 125 Volts: 12/60 Amps
  • FLA/LRA 250 Volts: 8/48 Amps
  • Contact Material: Silver Alloy for reliable conductivity
  • Mounting Type: Insert Mount

4. Setup and Installation

IMPORTANT: Ensure power is disconnected before proceeding with installation.

  1. Power Disconnection: Turn off the main power supply to the HVAC unit or circuit where the relay will be installed. Verify power is off using a voltage tester.
  2. Identify Wiring: Carefully note the existing wiring connections if replacing an old relay. Take photos or draw a diagram for reference.
  3. Mounting: Securely mount the PR380 relay in the designated location using its insert mount feature. Ensure it is stable and not subject to excessive vibration.
  4. Wiring Connections:
    • Connect the 24 VAC control wires to the relay coil terminals.
    • Connect the load wires (e.g., fan motor, solenoid) to the appropriate 1/4-inch quick connect terminals for the Normally Open (NO) or Normally Closed (NC) contacts, as required by your system's wiring diagram.
    • Ensure all quick connect terminals are firmly seated.
  5. Verify Connections: Double-check all wiring against the system's schematic to ensure correct and secure connections.
  6. Restore Power: Once all connections are verified, restore power to the HVAC unit.
  7. Test Operation: Test the functionality of the controlled device (e.g., fan motor) to confirm the relay is operating correctly.

5. Operating Instructions

The Packard PR380 Fan Relay operates based on the presence or absence of a 24 VAC control signal to its coil. When the control signal is applied, the relay coil energizes, causing the internal contacts to change state:

  • Normally Open (NO) Contacts: These contacts are open when the coil is de-energized and close when the coil is energized, completing the circuit to the controlled device.
  • Normally Closed (NC) Contacts: These contacts are closed when the coil is de-energized and open when the coil is energized, breaking the circuit to the controlled device.

The relay acts as an electrical switch, allowing a low-voltage control signal (24 VAC) to control a higher-voltage load circuit (125V or 250V) for components such as furnace fan motors, air conditioner condenser fans, or various solenoids within an HVAC system.

6. Maintenance

The Packard PR380 Fan Relay is designed for reliable, long-term operation with minimal maintenance. However, periodic inspection can help ensure continued performance:

  • Visual Inspection: Annually inspect the relay and its connections for any signs of wear, corrosion, or loose wiring.
  • Cleanliness: Ensure the relay is free from excessive dust, dirt, or debris, which can impede heat dissipation or contact operation. Use a soft, dry brush or compressed air for cleaning.
  • Connection Integrity: Verify that all quick connect terminals remain firmly attached to their respective wires.
  • Do Not Disassemble: The relay is a sealed unit. Do not attempt to disassemble or repair internal components, as this will void the warranty and may compromise safety.

7. Troubleshooting

If you experience issues with your Packard PR380 Fan Relay, consider the following common troubleshooting steps:

SymptomPossible CauseSolution
Relay coil does not energize (no click sound)No 24 VAC control voltage to coil; faulty coil; loose wiring.Check for 24 VAC at coil terminals. Verify control circuit wiring. Replace relay if coil is faulty.
Controlled device (e.g., fan) runs continuouslyRelay contacts are stuck closed; continuous control signal.Verify control signal is cycling correctly. If signal is off but fan runs, replace relay.
Controlled device does not receive power when relay is energizedFaulty relay contacts (not closing); loose load wiring; open circuit in load.Check continuity across contacts when coil is energized. Inspect load wiring. Replace relay if contacts are faulty.
Relay makes buzzing noiseLow coil voltage; foreign object in armature; faulty coil.Check 24 VAC coil voltage. Ensure no obstructions. Replace relay if buzzing persists.

If troubleshooting steps do not resolve the issue, it is recommended to consult a qualified HVAC technician or electrician.

8. Specifications

SpecificationValue
Model NumberPR380
Coil Voltage24 VAC
Contact TypeSPST Normally Open (NO) and Normally Closed (NC)
Resistive Current Rating18 A
FLA/RLA 125 Volts12/60 Amps
FLA/LRA 250 Volts8/48 Amps
Maximum Switching Voltage250 Volts
Minimum Switching Voltage24 Volts AC
Connector Type1/4-inch Quick Connect
Contact MaterialSilver Alloy
Mounting TypeInsert Mount
Operation ModeAutomatic
Item Weight0.27 g
ManufacturerPACKARD

9. Warranty and Support

This Packard PR380 Fan Relay comes with a 30-day warranty from the date of purchase, covering defects in materials and workmanship under normal use. This warranty does not cover damage resulting from improper installation, misuse, abuse, or unauthorized modifications.

For technical assistance, warranty claims, or product inquiries, please contact your original vendor or the manufacturer, Packard, through their official support channels. Please have your purchase receipt and product model number (PR380) available when contacting support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.