1. Introduction
This manual provides essential information for the safe and efficient operation of your Dometic DX P800 PMA1000 water pump. This pump is designed for marine and RV applications, featuring a magnetic-drive impeller and a robust construction suitable for harsh environments. Please read this manual thoroughly before installation and use.

Figure 1: Dometic DX P800 PMA1000 Water Pump. This image shows the compact design of the pump, featuring a red motor housing and a light-colored plastic pump head with threaded connections. A power cord extends from the motor housing.
2. Safety Information
Adherence to the following safety guidelines is crucial for preventing injury and damage to the equipment.
- Always disconnect power before performing any installation, maintenance, or troubleshooting.
- Ensure the power supply matches the pump's voltage requirements (115V, 50/60 Hz).
- Install the pump in a location that allows for proper ventilation and access for maintenance.
- Do not operate the pump dry. Ensure it is submerged or primed with liquid before activation.
- All electrical connections must be made by a qualified professional and comply with local codes.
- Keep children and unauthorized personnel away from the pump during operation.
3. Product Features
The Dometic DX P800 PMA1000 water pump incorporates several design elements for reliable performance:
- Efficient and Powerful: Delivers 8.5 gallons per minute (GPM) with an efficient motor, optimizing power consumption.
- Magnetic-Drive Impeller: Features a magnetic-drive impeller design, eliminating traditional seals prone to leaks and wear, thus reducing maintenance needs.
- Marine-Grade Base: Equipped with an exclusive marine-grade base for enhanced durability and resistance to harsh marine conditions.
- Liquid-Cooled and Durable: Submersible and liquid-cooled for sustained performance. Components in contact with water are made from plastic, ceramic, or stainless steel for corrosion resistance.
- Easy Installation: Comes with a 6 ft. (1.8 m) power cord and requires no additional fittings for typical installation.
4. Setup and Installation
Follow these steps for proper installation of the Dometic DX P800 PMA1000 water pump:
- Choose Location: Select a stable, level surface for mounting the pump. Ensure adequate space for air circulation around the motor and access for future maintenance.
- Mounting: Secure the pump using appropriate fasteners through the mounting holes on the marine-grade base.
- Plumbing Connections: Connect the inlet and outlet hoses to the pump. The pump is designed for direct connection without additional fittings. Ensure all connections are tight to prevent leaks.
- Electrical Connection: The pump comes with a 6 ft. (1.8 m) power cord. Connect the power cord to a dedicated 115V, 50/60 Hz power supply. Ensure the circuit is protected by an appropriate fuse or circuit breaker. Consult a qualified electrician if unsure about electrical wiring.
- Priming (if not submersible): If the pump is not fully submerged, it must be primed before initial operation. Ensure the pump casing is filled with water before starting.
- Final Check: Double-check all connections (plumbing and electrical) before applying power.
5. Operating Instructions
Operating the Dometic DX P800 PMA1000 is straightforward:
- Ensure Submersion/Priming: Verify that the pump is either fully submerged in the liquid it will be pumping or has been properly primed if installed above the liquid level.
- Apply Power: Turn on the power supply to the pump. The pump should begin operating immediately.
- Monitor Flow: Observe the water flow to ensure proper operation. The pump is designed for continuous duty when submerged.
- Shut Down: To stop the pump, simply turn off the power supply.
Note: Avoid running the pump dry, as this can cause damage to the magnetic-drive impeller and motor.
6. Maintenance
The Dometic DX P800 PMA1000 water pump is designed for minimal maintenance due to its magnetic-drive impeller. However, periodic checks are recommended:
- Regular Inspection: Periodically inspect the pump and its connections for any signs of wear, damage, or leaks.
- Cleanliness: Ensure the pump's intake is free from debris that could obstruct flow.
- Winterization (if applicable): In freezing conditions, ensure the pump and associated plumbing are drained to prevent ice damage.
- No Seal Replacement: Due to the magnetic-drive design, there are no seals to wear or replace.
7. Troubleshooting
Refer to the table below for common issues and their solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump does not start | No power; tripped circuit breaker/blown fuse; faulty wiring. | Check power supply; reset breaker/replace fuse; inspect wiring. |
| Low or no flow | Clogged intake/outlet; air in system (not primed); pump running dry. | Clear obstructions; prime the pump; ensure pump is submerged. |
| Unusual noise/vibration | Debris in impeller; loose mounting; pump running dry. | Inspect and clear impeller; tighten mounting bolts; ensure proper liquid supply. |
| Pump leaks | Loose plumbing connections; damaged pump housing. | Tighten connections; inspect housing for cracks (contact support if damaged). |
If the problem persists after attempting these solutions, contact Dometic customer support.
8. Specifications
| Attribute | Value |
|---|---|
| Brand | Dometic |
| Model Number | LC3CPMD115 |
| Material | Plastic (components in contact with water) |
| Style | Submersible |
| Power Source | Corded Electric |
| Item Weight | 0.01 Ounces |
| Maximum Flow Rate | 8.5 Gallons Per Minute |
| Maximum Lifting Height | 18.5 Inches |
| UPC | 637243493971 |
| Package Dimensions | 11.61 x 7.44 x 6.14 inches |
9. Warranty and Support
For specific warranty details and terms, please refer to the documentation included with your purchase or visit the official Dometic website. Dometic provides customer support for product inquiries, technical assistance, and warranty claims.
Contact Information:
- Brand: Dometic
- Website: www.dometic.com (Please check the official website for the most current contact information and support resources.)