Moen 8314

Moen 8314 M-Power 1-1/4-Inch Urinal Battery Powered Electronic Flush Valve Instruction Manual

Model: 8314

Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of the Moen 8314 M-Power 1-1/4-Inch Urinal Battery Powered Exposed Sensor-Operated Electronic Flush Valve. Please read these instructions carefully before installation and use to ensure proper function and longevity of the product.

The Moen 8314 features AccuSet piston technology for precise flush volume and a durable cast brass body with a chrome finish. It is designed for urinal applications and operates on battery power.

Safety Information

Package Contents

Verify that all components are present before beginning installation:

Moen 8314 M-Power Urinal Flush Valve, main product image

Image: The Moen 8314 M-Power Urinal Flush Valve in chrome finish, showing the main unit and associated piping.

Specifications

FeatureDetail
Model Number8314
BrandMoen
Installation TypeUrinal, Exposed
Flush Volume1.0 gpf (gallons per flush)
Power SourceBattery Powered (Batteries not included)
MaterialCast Brass
FinishChrome
TechnologyAccuSet Piston Technology, Sensor-Operated
Mechanical OverrideYes
Overall Height16.25 inches
Overall Width7.25 inches
Product Weight10.55 lbs

Setup and Installation

Before installation, ensure the water supply to the urinal is turned off. This flush valve is designed for exposed urinal installations.

Tools Required (Not Included):

Installation Steps:

  1. Prepare Water Supply: Ensure the water supply line is clean and free of debris. Apply pipe sealant tape to the threads of the water supply pipe.
  2. Install Stops: Attach the included stops to the water supply line. Tighten securely but do not overtighten.
  3. Mount the Flush Valve: Position the flush valve assembly onto the urinal. Connect the flush valve to the stops and the urinal inlet. Ensure all connections are hand-tight before using a wrench.
  4. Secure Connections: Use an adjustable wrench to carefully tighten all connections. Avoid excessive force to prevent damage.
  5. Install Batteries: Open the battery compartment (refer to diagram in physical manual if available) and insert the required batteries. Ensure correct polarity. (Note: Batteries are not included with the product).
  6. Check for Leaks: Slowly turn on the main water supply. Inspect all connections for any signs of leaks. Tighten connections further if necessary.
  7. Test Operation: Proceed to the "Operating Instructions" section to test the sensor and flush mechanism.
Moen 8314 M-Power Urinal Flush Valve installed on a urinal

Image: The Moen 8314 M-Power flush valve shown installed on a white urinal, demonstrating its exposed mounting style.

Operating Instructions

The Moen 8314 M-Power flush valve is sensor-operated, providing hands-free flushing. It also includes a mechanical override for manual flushing.

Sensor Operation:

Mechanical Override:

Close-up of Moen 8314 M-Power Urinal Flush Valve sensor and mechanical override

Image: A detailed view of the Moen 8314 M-Power flush valve, highlighting the sensor window and the mechanical override button.

Maintenance

Regular maintenance ensures optimal performance and extends the life of your Moen 8314 flush valve.

Cleaning:

Battery Replacement:

AccuSet Piston Technology:

The AccuSet piston technology includes a stainless steel self-cleaning filter designed to protect against clogs and damage, minimizing maintenance requirements for the internal mechanism.

Internal piston assembly of Moen 8314 M-Power flush valve

Image: A view of the internal piston assembly, which incorporates the AccuSet technology and self-cleaning filter for consistent performance.

Troubleshooting

This section addresses common issues you might encounter with your Moen 8314 M-Power flush valve.

ProblemPossible CauseSolution
No Flush (Sensor)
  • Low or dead batteries
  • Sensor window obstructed or dirty
  • Water supply off
  • Replace batteries.
  • Clean sensor window.
  • Ensure water supply is on.
Continuous Flush
  • Sensor malfunction
  • Debris in valve
  • Contact customer support.
  • Turn off water supply and inspect valve for debris (professional assistance recommended).
Weak Flush
  • Low water pressure
  • Partially closed stop valve
  • Debris in valve or filter
  • Check building water pressure.
  • Ensure stop valve is fully open.
  • Inspect and clean the self-cleaning filter (AccuSet piston).
Leaks
  • Loose connections
  • Damaged seals/gaskets
  • Turn off water supply and tighten connections.
  • Turn off water supply and inspect/replace seals or gaskets.

Warranty Information

Moen products are manufactured under the highest standards of quality and workmanship. For detailed warranty information, please refer to the official Moen website or contact Moen customer service. Keep your proof of purchase for warranty claims.

You can find more information at the official Moen website: www.moen.com

Customer Support

If you require further assistance or have questions not covered in this manual, please contact Moen customer support.

Related Documents - 8314

Preview Moen Commercial Battery Powered Exposed Type Flush Valve Installation and Owner's Manual
Comprehensive installation guide, troubleshooting steps, and warranty information for the Moen Commercial Battery Powered Exposed Type Flush Valve (Model INS1203B). Covers setup, maintenance, and part identification.
Preview Moen Commercial Battery Powered Exposed Flush Valve INS10160 - Installation & Owner's Manual
Detailed installation guide, parts list, troubleshooting, and warranty information for the Moen Commercial Battery Powered Exposed Type Flush Valve (Model INS10160).
Preview MOEN Touchless Urinal Flusher: Installation Guide and User Manual
Comprehensive installation instructions, technical specifications, and maintenance guide for the MOEN Touchless Urinal Flusher. Learn how to install, operate, and troubleshoot your MOEN urinal flush valve.
Preview Moen M-CORE 3-Series Showering Quick Start Guide
Concise guide to installing and understanding the Moen M-CORE 3-Series showering valve system, featuring installation benefits, valve options, and trim compatibility.
Preview Moen Tub/Shower Valve Trim Installation Instructions and Troubleshooting Guide
Comprehensive installation guide and troubleshooting manual for Moen single-handle tub/shower and shower-only valve trims (Model INS10717-2/18), including parts lists, step-by-step instructions, care, cleaning, and warranty information.
Preview Moen M-Core™ with Built-in Transfer Valve Installation Instructions
Comprehensive installation guide for Moen M-Core™ valves (U232 and U362 series), detailing wall preparation, valve placement, assembly steps, plumbing connections, and warranty information.