Taylor 9306N

Taylor 9306N Dual Temp Infrared Thermocouple Thermometer Instruction Manual

Model: 9306N

1. Introduction

The Taylor 9306N Dual Temp Infrared Thermocouple Thermometer is a versatile instrument designed for accurate temperature measurement. It combines two distinct measurement technologies: an infrared sensor for quick surface temperature readings and a fold-out thermocouple probe for precise internal temperature measurements. This manual provides essential information for the proper use, care, and maintenance of your thermometer.

Taylor 9306N Dual Temp Infrared Thermocouple Thermometer with its black nylon storage case.

Image 1: The Taylor 9306N Dual Temp Infrared Thermocouple Thermometer, shown with its protective black nylon storage case.

2. Product Features

  • Dual Measurement: Combines infrared (IR) for surface temperatures and a thermocouple probe for internal temperatures.
  • Wide Temperature Ranges: IR mode: -67°F to 482°F (-55°C to 250°C); Thermocouple mode: -67°F to 626°F (-55°C to 330°C).
  • High Accuracy: Thermocouple accuracy of ±2°F/±1°C.
  • Dual Line LCD: Displays current and previous readings simultaneously.
  • HOLD Function: Freezes the current temperature reading on the display.
  • Min/Max Function: Records the minimum and maximum temperatures measured.
  • HACCP Light System: Provides visual indication for safe temperature zones.
  • IP65 Water Resistant: Protected against dust and low-pressure water jets.
  • Auto-Off: Conserves battery life by automatically shutting down after a period of inactivity.
  • NSF Certified: Meets public health and safety standards.
  • Included Accessories: Comes with a black nylon storage case.

3. Safety Information

Please read and understand all safety instructions before using this thermometer.

  • Probe Safety: The thermocouple probe is sharp. Handle with care to prevent injury. Do not touch the probe immediately after use, as it may be hot.
  • Infrared Laser: The infrared function uses a laser pointer. Do not stare directly into the laser beam or point it at people or animals. Avoid direct eye exposure.
  • Battery Safety: Use only the specified battery type (2 AAA). Do not mix old and new batteries or different battery types. Dispose of batteries according to local regulations.
  • Cleaning: Refer to the 'Maintenance and Care' section for proper cleaning instructions. Do not immerse the entire unit in water, despite its water-resistant rating.
  • Storage: Store the thermometer in its protective case when not in use to prevent damage.

4. Setup

4.1 Battery Installation

  1. Locate the battery compartment on the back of the thermometer.
  2. Open the battery compartment cover.
  3. Insert two (2) AAA batteries, ensuring correct polarity (+/-) as indicated inside the compartment.
  4. Close the battery compartment cover securely.

4.2 Initial Power On

Press the 'Scan' or 'Probe' button to turn on the thermometer. The display will illuminate, showing the last measured temperature or default settings.

Front view of the Taylor 9306N thermometer, showing the dual LCD display and control buttons.

Image 2: Front view of the Taylor 9306N thermometer, highlighting the display and control buttons.

5. Operating Instructions

5.1 Unit Selection (°F/°C)

To switch between Fahrenheit (°F) and Celsius (°C), press the 'Mode' button. The selected unit will be displayed on the LCD.

5.2 Infrared (IR) Mode

The IR mode is used for quick, non-contact surface temperature measurements.

  1. Ensure the thermocouple probe is folded into the unit.
  2. Press the 'Scan' button to activate the infrared sensor. A laser pointer will indicate the measurement area.
  3. Point the thermometer at the desired surface. The distance-to-spot ratio is 3:1, meaning at a distance of 3 inches, it measures a 1-inch diameter spot. Adjust distance for desired spot size.
  4. Hold the 'Scan' button for continuous reading, or press and release for a single reading. The temperature will be displayed on the upper line of the LCD.

5.3 Thermocouple Probe Mode

The fold-out probe is used for accurate internal temperature measurements of food and liquids.

  1. Unfold the stainless steel probe until it locks into position.
  2. Press the 'Probe' button to activate the probe sensor.
  3. Insert the probe tip into the center of the food item or liquid, ensuring it is not touching bone or the bottom of the container.
  4. Wait for the reading to stabilize. The temperature will be displayed on the lower line of the LCD.
Close-up view of the sharp, pointed tip of the thermocouple probe.

Image 3: Close-up of the thermocouple probe tip, designed for precise internal temperature readings.

5.4 HOLD Function

To hold the current temperature reading on the display, press the 'HOLD' button (often integrated with 'Scan' or 'Probe' button, requiring a second press after measurement). The reading will remain until the button is pressed again or the unit automatically turns off.

5.5 Min/Max Function

This function allows you to view the minimum and maximum temperatures recorded during a measurement session.

  1. While in measurement mode, press the 'Mode' button repeatedly to cycle through current, minimum (MIN), and maximum (MAX) temperature readings.
  2. The display will indicate 'MIN' or 'MAX' next to the temperature.
  3. To clear the Min/Max memory, typically hold the 'Mode' button for a few seconds. Refer to the on-device markings for specific button functions.

5.6 HACCP Light System

The HACCP (Hazard Analysis and Critical Control Points) light system provides a quick visual reference for food safety temperatures.

  • Green Light: Indicates a safe temperature zone.
  • Red Light: Indicates a potentially unsafe temperature zone, requiring corrective action.

Consult local food safety guidelines for specific temperature requirements.

6. Maintenance and Care

6.1 Cleaning

The thermometer is IP65 water resistant, meaning it can withstand splashes and low-pressure water jets. However, it is not designed for full immersion.

  • Probe: Clean the stainless steel probe with a damp cloth and mild soap before and after each use. Rinse thoroughly and dry completely.
  • Body: Wipe the body of the thermometer with a damp cloth. Do not use abrasive cleaners or immerse the unit in water.
  • Product Care Instructions: Hand Wash Only.

6.2 Storage

When not in use, fold the probe back into the unit and store the thermometer in its provided black nylon case. Store in a cool, dry place away from direct sunlight and extreme temperatures.

7. Troubleshooting

If you encounter issues with your thermometer, refer to the following common problems and solutions:

ProblemPossible CauseSolution
No display or dim displayLow or dead batteriesReplace with two new AAA batteries. Ensure correct polarity.
Inaccurate readings (probe)Probe not inserted deep enough or touching bone/containerEnsure probe tip is in the center of the food/liquid, away from bones or container walls.
Inaccurate readings (IR)Incorrect distance-to-spot ratio or reflective surfaceAdjust distance to ensure the measurement spot covers the desired area. IR thermometers are less accurate on highly reflective surfaces.
Unit does not turn onBatteries incorrectly installed or unit malfunctionCheck battery installation. If problem persists after battery replacement, contact customer support.

8. Specifications

FeatureDetail
BrandTaylor
Model NameDual Temp Infrared Thermocouple Thermometer
Model Number9306N
ColorBlack
Display TypeDigital LCD (Dual Line)
Connectivity TechnologyInfrared
Power SourceBattery Powered (2 AAA batteries required)
IR Temperature Range-67°F to 482°F (-55°C to 250°C)
Thermocouple Temperature Range-67°F to 626°F (-55°C to 330°C)
Thermocouple Accuracy±2°F / ±1°C
Response Time500 Milliseconds (IR)
Distance-to-Spot Ratio3:1 (IR)
Water ResistanceIP65 Rated
MaterialNylon (Outer Material)
Item Weight4.8 ounces
Item Length4 Inches
CertificationsHACCP, NSF
Included ComponentsThermometer, Nylon Case

9. Battery Information

The Taylor 9306N thermometer operates on two (2) AAA batteries. To ensure optimal performance and battery life:

  • Always use fresh, high-quality AAA batteries.
  • Replace both batteries at the same time. Do not mix old and new batteries.
  • Remove batteries if the unit will not be used for an extended period to prevent leakage.
  • The thermometer features an auto-off function to conserve battery power.

10. Warranty and Support

Specific warranty details are not provided in the product information. For warranty claims, technical support, or further assistance, please contact the manufacturer, Lifetime Brands Inc., or refer to the product packaging for customer service contact information.

Related Documents - 9306N

Preview Taylor 5309295 Waterproof Wireless Meat Thermometer with Charging Case Instruction Manual
Instruction manual for the Taylor 5309295 Waterproof Wireless Meat Thermometer with Charging Case, detailing setup, usage, product specifications, care, precautions, FCC compliance, and warranty information.
Preview Taylor 5309295 Wireless Bluetooth Thermometer - Features and Usage
Detailed information on the Taylor 5309295 Wireless Bluetooth Thermometer, including its specifications, features, multiple cooking uses, ease of cleaning, and system pairing instructions. Wirelessly track temperatures in ovens, grills, and smokers with this IPX7 waterproof and rechargeable device.
Preview Taylor Five Star Wireless Thermometer with Remote Pager Plus Timer Instruction Manual
This instruction manual provides detailed guidance for the Taylor Five Star Wireless Thermometer with Remote Pager plus Timer (models 1479, 1479-21, 532, 532-77). Learn setup, operation, programming, timer functions, clock settings, care, precautions, and troubleshooting for your digital cooking thermometer.
Preview Digital Thermometer & Adaptor for E-61 Groupheads - Brew Temperature Measurement Guide
Comprehensive guide to installing and using the Digital Thermometer & Adaptor for E-61 Groupheads. Learn to accurately measure brew water temperature for better espresso. Includes kit contents, installation, operation, and maintenance.
Preview Taylor 9840 Digital Meat Thermometer: Quick Start Guide and Cooking Temperatures
Learn how to use the Taylor 9840 digital meat thermometer, including temperature ranges, USDA cooking guidelines, battery replacement, and important cautions for accurate food preparation. Features include a clear display and durable design.
Preview Taylor 5294302 Programmable Digital Wired Thermometer - User Guide & Specifications
Concise guide for the Taylor 5294302 Programmable Digital Wired Thermometer, covering temperature ranges, usage, care, and warranty information.