Nady PM-200A

Nady PM-200A Powered Personal Stage Monitor User Manual

Model: PM-200A

1. Introduction

The Nady PM-200A is a powered personal stage monitor designed to provide musicians and performers with clear, localized audio monitoring on stage or during rehearsals. This unit features powerful amplification and a comprehensive set of controls, allowing users to customize their sound mix directly. Its compact and durable design makes it suitable for various performance environments.

The PM-200A is engineered to minimize feedback while enhancing the clarity of vocals and instruments within the overall mix. It offers flexible connectivity options for integration with main or monitor mixers, or for direct connection of instruments and microphones.

2. Key Features

  • Personal Monitoring: Designed to deliver sound directly to the performer, reducing stage clutter and overall stage volume.
  • Powerful Sound: Equipped with a pair of 5-inch Ferro-fluid drivers for clear, high SPL audio with low distortion and excellent feedback rejection.
  • Integrated Amplifier: Features a 150W RMS internal amplifier capable of powering the internal drivers and up to four Nady PM-100 passive monitors via two external 1/4-inch speaker outputs.
  • High Output: Achieves up to 125dB SPL (Max) to ensure audibility in loud environments.
  • Flexible Positioning: Can be positioned at four different angles for optimal sound projection. Includes an integrated 5/8-inch socket for microphone stand mounting (adapter sold separately).
  • Versatile Inputs: Balanced XLR and 1/4-inch inputs accommodate a variety of audio sources.
  • Multiple Outputs: Includes 1/4-inch line output for daisy-chaining or connecting to mixers/PAs, and a 1/4-inch headphone output for private monitoring.
  • Protection Circuitry: MOSFET circuitry with thermal, short circuit, and anti-thump on/off protection.

3. Setup Guide

3.1 Unpacking and Initial Inspection

Carefully remove the PM-200A from its packaging. Inspect the unit for any signs of damage that may have occurred during shipping. Retain the packaging for future transport or storage.

3.2 Placement

Position the PM-200A in a location that provides optimal monitoring for the performer. The unit can be placed on a floor, keyboard, amplifier, or table. Its design allows for four different angled positions to direct sound effectively. For elevated monitoring, the integrated 5/8-inch socket allows mounting on a standard microphone stand (requires an optional adapter).

Nady PM-200A Personal Stage Monitor angled view

Figure 1: Angled view of the Nady PM-200A, demonstrating its wedge design for floor placement.

Nady PM-200A Personal Stage Monitor front view

Figure 2: Front view of the Nady PM-200A, showing the protective grille and Nady logo.

3.3 Power Connection

Before connecting the power cable, ensure the PM-200A's power switch is in the "OFF" position. Connect the provided AC power cable to the power inlet on the rear panel of the unit, then plug the other end into a suitable AC power outlet. The unit supports 115V/60Hz or 230V/50Hz operation; verify the voltage selector switch is set correctly for your region.

4. Connections

The PM-200A offers a range of input and output options for flexible integration into any audio setup. Refer to the rear panel diagram below for connection points.

Nady PM-200A Personal Stage Monitor rear panel connections

Figure 3: Rear panel of the Nady PM-200A, detailing all input, output, and control sections.

4.1 Inputs

  • MIC Input (Balanced XLR): Connect a microphone directly to this input. The impedance is 2kΩ.
  • LINE Input (Balanced/Unbalanced 1/4" TRS): Connect a line-level signal from a main mixer, monitor mixer, instrument pre-amp, or other audio device. Impedance is 20kΩ (balanced) or 10kΩ (unbalanced).

4.2 Outputs

  • LINE OUT (Balanced XLR): Provides a balanced line-level output for daisy-chaining multiple PM-200A units or sending the mixed signal to a main PA system or recording device. Output impedance is 1.4kΩ.
  • HEADPHONES (1/4" TRS Stereo): Connect stereo headphones for private monitoring.
  • EXTERNAL SPEAKERS (Two 1/4" Outputs): These outputs can power up to four Nady PM-100 passive monitors. Ensure the total impedance connected to these outputs is not less than 4Ω. The internal speakers can operate simultaneously or be disabled via the "Speaker Enable" switch.

5. Operation

5.1 Powering On/Off

After all connections are made, switch the "POWER" toggle switch on the rear panel to the "ON" position. To power off, switch it to "OFF". It is recommended to power on the PM-200A after other audio equipment and power it off before other equipment to prevent "thump" noises.

5.2 Volume Control

The "VOLUME" knob adjusts the overall output level of the monitor. Start with the volume at a low setting and gradually increase it to a comfortable listening level.

5.3 Equalization (EQ) Controls

The PM-200A features three EQ knobs to shape the frequency response of your monitor mix:

  • HIGH (10kHz): Adjusts the treble frequencies. Turn clockwise to boost, counter-clockwise to cut.
  • MID (2.5kHz): Adjusts the mid-range frequencies, crucial for vocal and instrument clarity. Turn clockwise to boost, counter-clockwise to cut.
  • BASS (120Hz): Adjusts the low frequencies. Turn clockwise to boost, counter-clockwise to cut.

Each EQ control offers a range of ±12dB. Adjust these controls to tailor the sound to your preference and to reduce feedback in your environment.

5.4 Internal Speaker Enable Switch

The "INTERNAL SPEAKERS" switch allows you to enable or disable the internal 5-inch speakers. This is useful if you are only using the external speaker outputs to power passive monitors or if you prefer to monitor solely through headphones.

6. Troubleshooting

ProblemPossible CauseSolution
No sound output
  • Power switch is OFF.
  • Volume knob is set too low.
  • Input cable is disconnected or faulty.
  • Internal speakers are disabled.
  • Source device is not sending signal.
  • Ensure power switch is ON.
  • Increase the VOLUME knob.
  • Check all input cables and connections. Test with a known working cable.
  • Verify the "INTERNAL SPEAKERS" switch is ON if using internal speakers.
  • Check the output of your source device (mixer, microphone).
Distorted or unclear sound
  • Input signal is too high (clipping).
  • Volume knob is set too high.
  • EQ settings are extreme.
  • Faulty cable or speaker.
  • Reduce the output level from your source device.
  • Lower the PM-200A's VOLUME knob.
  • Adjust EQ knobs to a more neutral position or cut problematic frequencies.
  • Test with different cables and, if possible, another speaker.
Humming or buzzing noise
  • Ground loop issue.
  • Poorly shielded cables.
  • Interference from other electronic devices.
  • Ensure all audio equipment is plugged into the same power circuit or use a ground loop isolator.
  • Use high-quality, shielded cables.
  • Move the unit or cables away from power transformers, fluorescent lights, or other sources of electromagnetic interference.
Unit gets hot
  • Normal operation under high power.
  • Insufficient ventilation.
  • The rear panel heat sink can get very hot during high-power operation. This is normal.
  • Ensure the unit has adequate ventilation and is not obstructed. Do not touch the heat sink during operation.

7. Care and Maintenance

  • Cleaning: Use a soft, dry cloth to clean the exterior of the unit. Do not use liquid cleaners or solvents, as they may damage the finish or internal components.
  • Ventilation: Ensure the rear heat sink is free from dust and debris. Always provide adequate airflow around the unit to prevent overheating, especially during extended use at high volumes.
  • Storage: When not in use for extended periods, store the PM-200A in a cool, dry place, preferably in its original packaging or a protective case.
  • Handling: Avoid dropping or subjecting the unit to severe impacts.

8. Specifications

FeatureDetail
Model NamePM-200A
Speaker TypeMonitor
Mounting TypeTabletop Mount, Mic Stand Mount (with optional adapter)
Power Output2 x 50W RMS @ 8Ω (Total 100W RMS) / 2 x 75W RMS @ 4Ω (Total 150W RMS)
Internal SpeakersTwo 5-inch full-range, 8Ω impedance
Mic InputBalanced XLR, Impedance: 2kΩ
Line InputBalanced/Unbalanced 1/4" TRS, Impedance: 20kΩ (balanced) / 10kΩ (unbalanced)
Line OutputBalanced XLR, Output Impedance: 1.4kΩ
Headphone Output1/4" TRS Stereo
EQ Controls±12dB (High: 10kHz / Mid: 2.5kHz / Low: 120Hz)
Frequency Response20Hz - 50kHz
THD0.055%
S/N Ratio-81dB
Product Dimensions6.1"D x 11.1"W x 7"H
Item Weight9.6 Pounds
ColorBlack
Included ComponentsPowered Personal Stage Monitor
Nady PM-200A Personal Stage Monitor with dimensions

Figure 4: Dimensions of the Nady PM-200A Personal Stage Monitor.

9. Warranty Information

The Nady PM-200A Powered Personal Stage Monitor comes with a limited warranty. For specific details regarding warranty coverage, duration, and terms, please refer to the warranty card included with your product or visit the official Nady Systems website. Keep your proof of purchase for warranty claims.

10. Customer Support

If you encounter any issues not covered in this manual or require further assistance, please contact Nady Systems customer support. Contact information can typically be found on the official Nady Systems website or on the product packaging.

For additional resources and product information, you may visit the Nady Store on Amazon.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.