1. Product Overview
The Bradley S19-921 is an on-site, gravity-fed portable eyewash unit designed for immediate eye flushing in emergency situations. It holds 7 gallons of potable water and features a lower tank that houses a push-down eyewash tray for activation. This unit is SEI certified to ANSI Z358.1-2009 standards, ensuring compliance with safety requirements.

This image displays the Bradley S19-921 On-Site Portable Gravity-Fed Eyewash unit. The unit is bright yellow and features a large upper tank for water storage, a central pull-down activation handle, and a lower basin designed for eye flushing. The 'FRONT' label is visible on the top of the tank, and instructions are printed on the side panels.
Key Features:
- Uses less space while delivering ANSI required 15 minute flush.
- Clear tank allows easy fill level check.
- Three mounting options: Wall, Bench Top, or Transportable Waste Cart.
- Allows for a fluid start/stop flow with no expensive cartridges to replace.
- Water preservative sold separately.
2. Setup and Installation
What's in the Box:
- Bradley S19-921 On-Site Portable Gravity-Fed Eyewash unit.
Installation:
For detailed installation instructions, please refer to the official Installation Manual PDF. Ensure the unit is placed on a stable, level surface or mounted securely using one of the three available options (Wall, Bench Top, or Transportable Waste Cart). Fill the upper tank with potable water up to the designated fill line. Water preservative should be added as per its manufacturer's instructions to maintain water quality.
Access the Installation Manual here: Installation Manual (PDF)
3. Operating Instructions
In case of eye exposure to hazardous materials, immediately proceed to the eyewash unit.
- Activate the Unit: Firmly grasp the pull handle located at the front of the unit and pull it down. This action will initiate the flow of water from the nozzles into the eyewash basin.
- Flush Eyes: Position your face over the basin and hold your eyelids open with your fingers. Allow the water to continuously flush both eyes for a minimum of 15 minutes. Rotate your eyeballs to ensure all surfaces are thoroughly rinsed.
- Seek Medical Attention: After flushing, seek immediate medical attention, even if symptoms appear to subside. Bring the Safety Data Sheet (SDS) of the chemical involved, if available.
- Stop Flow: To stop the water flow, push the handle back up to its original position.
Note: No official product videos from the seller were available for embedding.
4. Maintenance
Regular maintenance is crucial to ensure the eyewash unit is always ready for use and functions correctly.
- Water Replacement: The potable water in the tank should be replaced regularly, typically every 120 days, or as recommended by the water preservative manufacturer.
- Water Preservative: Always use a suitable water preservative to prevent the growth of bacteria, algae, and other contaminants. Follow the preservative manufacturer's instructions for dosage and frequency.
- Inspection: Periodically inspect the unit for any signs of damage, leaks, or blockages in the nozzles. Ensure the pull handle operates smoothly.
- Cleaning: Clean the eyewash basin and nozzles regularly to prevent buildup and maintain hygiene.
- Functionality Test: Conduct weekly activation tests to ensure proper water flow and operation. Briefly activate the unit to verify water discharge.
5. Troubleshooting
If you encounter issues with your Bradley S19-921 eyewash unit, consider the following common troubleshooting steps:
- No Water Flow or Weak Flow:
- Check if the tank is adequately filled with water.
- Ensure the pull handle is fully actuated.
- Inspect nozzles for any blockages or debris.
- Leaks:
- Verify that all connections are secure and properly sealed.
- Inspect the tank for any cracks or damage.
- Ensure the tank is correctly seated on the base.
- Water Quality Issues:
- Confirm that water preservative has been added and is effective.
- Replace the water and preservative according to the recommended schedule.
If problems persist after attempting these steps, contact Bradley customer support for further assistance.
6. Specifications
| Attribute | Detail |
|---|---|
| Item Model Number | S19-921 |
| Manufacturer | Bradley Fixtures Corporation |
| Date First Available | February 17, 2007 |
| National Stock Number | 4240-01-234-1796 |
| Department | Tools |
| ASIN | B000LDJ2NM |
7. Warranty Information
The Bradley S19-921 On-Site Portable Gravity-Fed Eyewash unit comes with a full, one-year warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use and service. Please retain your proof of purchase for warranty claims.
8. Support
For additional support, product information, or to purchase accessories and replacement parts, please visit the official Bradley store or contact their customer service.
Visit the Bradley Store: Bradley Store on Amazon