Introduction
The BELL 5146-5 Weatherproof Device Cover is designed to provide robust protection for outdoor electrical receptacles. This single-gang cover features a durable metal construction with a state-of-the-art powder-coated finish, ensuring maximum weatherability and resistance to scratches. It is specifically engineered for vertical mounting over duplex receptacles, offering reliable NEMA 3R rated protection against environmental elements.

Image: Front view of the BELL 5146-5 Weatherproof Device Cover in gray, showing the self-closing lid and the "BELL" branding. This cover is designed for wet locations.
Safety Information
Please read and understand all safety information before installation and use. Failure to follow these instructions may result in electric shock, fire, or property damage.
- Electrical Safety: This device cover is intended for use with 120-volt electrical systems. Ensure power is disconnected at the circuit breaker before beginning any installation work.
- Qualified Personnel: Installation should be performed by a qualified electrician or a knowledgeable individual familiar with electrical wiring practices and local electrical codes.
- Proposition 65 Warning: This product may expose you to chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.
- Intended Use: Use this cover only for its intended purpose of protecting outdoor duplex receptacles. Do not modify the product.
- Certification: This product is CSA Certified and UL Listed, ensuring it meets recognized safety standards.
Package Contents
Verify that all components are present before beginning installation:
- BELL 5146-5 Weatherproof Device Cover (1 unit)
- Installation Hardware (screws)
- Gasket (for weatherproof seal)
- Multi-Lingual Instructions
Setup and Installation
Follow these steps for proper installation of your weatherproof device cover:
- Disconnect Power: Before starting, turn off the power to the electrical outlet at the main circuit breaker or fuse box. Verify that the power is off using a voltage tester.
- Remove Existing Cover (if applicable): Carefully remove any existing cover plate from the duplex receptacle.
- Prepare the Surface: Ensure the mounting surface is clean, dry, and flat to allow for a proper seal.
- Position the Gasket: Place the provided gasket over the electrical box opening. The gasket helps create a watertight seal between the cover and the mounting surface.
- Mount the Cover: Align the BELL 5146-5 device cover over the duplex receptacle and the gasket. The cover is designed for vertical mounting. Use the included installation hardware (screws) to securely fasten the cover to the electrical box. Do not overtighten the screws, as this can damage the cover or the electrical box.
- Test Operation: Once installed, ensure the self-closing lid operates smoothly and fully closes to provide weatherproof protection.
- Restore Power: Turn the power back on at the circuit breaker.

Image: A hand holding the BELL 5146-5 Weatherproof Device Cover, illustrating its approximate dimensions for installation reference.
Operating Instructions
The BELL 5146-5 Weatherproof Device Cover is designed for simple and effective operation:
- Accessing Receptacle: To use the electrical receptacle, simply lift the self-closing lid.
- Weatherproof Protection: When not in use, ensure the lid is fully closed. The self-closing mechanism is designed to automatically return the lid to the closed position, maintaining the NEMA 3R weatherproof seal and protecting the outlet from rain, snow, and debris.
Maintenance
The BELL 5146-5 Weatherproof Device Cover requires minimal maintenance due to its durable construction and powder-coated finish.
- Cleaning: Periodically wipe the cover with a damp cloth to remove dirt or dust. Avoid using abrasive cleaners or solvents, as these may damage the finish.
- Inspection: Regularly inspect the cover and gasket for any signs of wear, cracks, or damage. Ensure the lid still closes securely. If any damage is observed, replace the cover to maintain weatherproof integrity.
Troubleshooting
Most issues with the device cover are related to installation or physical damage.
| Problem | Possible Cause | Solution |
|---|---|---|
| Lid does not close completely. | Obstruction, damaged hinge, or improper installation. | Check for debris around the hinge. Inspect the hinge for damage. Re-check installation to ensure the cover is not warped or misaligned. |
| Water inside the cover. | Damaged or improperly seated gasket, or lid not fully closed. | Ensure the gasket is properly seated and not damaged. Verify the lid closes completely. Replace gasket or cover if necessary. |
| Cover feels loose after installation. | Mounting screws are not tightened sufficiently. | Carefully tighten the mounting screws. Do not overtighten. |
Specifications
| Feature | Detail |
|---|---|
| Brand | BELL |
| Model Number | 5146-5 |
| Material | Metal |
| Color | Gray |
| Product Dimensions (W x H) | 2.94"W x 4.94"H |
| Size (L x W) | 4-9/16"L x 2-13/16"W |
| Item Weight | 3.87 ounces |
| Finish Type | Powder Coated |
| Installation Type | Screw-In |
| Mounting | Vertical |
| NEMA Rating | 3R |
| Certifications | CSA Certified, UL Listed |
| Voltage | 120 Volts |
| UPC | 050169514658 |
Warranty and Support
Specific warranty details for the BELL 5146-5 Weatherproof Device Cover are typically provided with the product packaging or can be obtained by contacting the manufacturer directly. For product support, technical assistance, or warranty claims, please contact BELL customer service.
Manufacturer: Hubbell
For further information, you may visit the official BELL store on Amazon: BELL Store