Introduction

This manual provides essential information for the installation, operation, and maintenance of the Franke FRFIM-605 component, designed for use with Franke Triflow Filtration systems. The FRFIM-605 is specifically intended as a hook-up kit for refrigerators and icemakers, facilitating the connection of these appliances to your filtered water supply.

The Franke Triflow Filtration system, including components like the FRFIM-605, has been independently tested against National Sanitation Foundation International (NSF) standards by Spectrum Laboratories and the Water Resource Center (WRC). These tests confirm compliance with NSF standard numbers 42, 53, and 61, satisfying the "lead-free" requirement.

Package Contents

Upon opening the package, verify that all components are present and undamaged. The FRFIM-605 package typically includes the following items:

  • Green flexible tubing (approximately 15-20 feet)
  • One (1) T-connector (push-fit type)
  • One (1) straight connector (push-fit type)
  • Two (2) brass compression fittings
  • One (1) brass nut
Franke FRFIM-605 Refrigerator/Icemaker Hook-up Kit components

Image: Components of the Franke FRFIM-605 kit, including green tubing, push-fit connectors, and brass fittings. These parts are used to connect a Franke Triflow Filtration system to a refrigerator's icemaker or water dispenser.

Setup and Installation

Before beginning installation, ensure you have all necessary tools and that the main water supply to your home or the specific area is turned off to prevent water damage.

Safety Precautions:

  • Always turn off the main water supply before making any connections.
  • Ensure all connections are secure to prevent leaks.
  • Do not overtighten fittings, as this can damage components.

Installation Steps:

  1. Prepare Water Supply: Locate the cold water supply line that will feed the filtration system. If connecting to an existing Franke Triflow system, identify the filtered water outlet.
  2. Connect to Filtration System (if applicable): Use the appropriate push-fit connector (straight or T-connector) to attach one end of the green tubing to the filtered water outlet of your Franke Triflow system. Ensure the tubing is fully inserted into the push-fit fitting until it seats firmly.
  3. Route Tubing: Carefully route the green tubing from the filtration system to the back of your refrigerator. Avoid kinks, sharp bends, or areas where the tubing could be pinched or damaged. Leave sufficient slack for moving the refrigerator.
  4. Connect to Refrigerator/Icemaker:
    • Identify the water inlet connection on the back of your refrigerator, typically a small copper or plastic tube.
    • If the refrigerator has a compression fitting, use the provided brass compression fittings and nut to secure the green tubing to the refrigerator's water inlet. Slide the nut and then the compression ring onto the green tubing, then insert the tubing into the refrigerator's inlet and tighten the nut.
    • If the refrigerator uses a push-fit connection, trim the green tubing cleanly and insert it directly into the refrigerator's push-fit inlet.
  5. Restore Water Supply: Slowly turn on the main water supply.
  6. Check for Leaks: Carefully inspect all connections for any signs of water leaks. Tighten connections as necessary.
  7. Flush System: Dispense several gallons of water through the refrigerator's water dispenser (if applicable) and allow the icemaker to produce a few batches of ice. This flushes air from the lines and ensures proper operation. Discard the first few batches of ice.

Operating Instructions

The FRFIM-605 is a passive component designed to facilitate water flow. Once properly installed, its operation is integrated with your Franke Triflow Filtration system and your refrigerator's water dispenser/icemaker. Ensure the main water supply is always on for continuous operation.

  • Water Flow: Water will flow through the FRFIM-605 tubing to your refrigerator whenever the refrigerator's water dispenser is activated or the icemaker calls for water.
  • Initial Use: After installation, it is crucial to flush the system as described in the Setup section to remove any air or carbon fines from the filtration system.

Maintenance

Regular maintenance of the FRFIM-605 component itself is minimal, as it is a durable connection kit. However, it is part of a larger filtration system that requires periodic attention.

  • Leak Inspection: Periodically check all connections of the FRFIM-605 tubing and fittings for any signs of leaks. Address any leaks immediately by tightening connections or replacing damaged components.
  • Tubing Condition: Inspect the green tubing for kinks, cracks, or wear. If the tubing appears damaged, it should be replaced to prevent leaks and ensure proper water flow.
  • Filter Replacement: Remember that the FRFIM-605 connects to a Franke Triflow Filtration system. Refer to your filtration system's manual for recommended filter replacement schedules. Regular filter replacement is essential for maintaining water quality.

Troubleshooting

If you encounter issues with your Franke FRFIM-605 component or the water supply to your refrigerator, consider the following common problems and solutions:

ProblemPossible CauseSolution
No water flow to refrigerator/icemaker
  • Main water supply off
  • Kinked or pinched tubing
  • Clogged filter (in filtration system)
  • Refrigerator water valve closed
  • Ensure main water supply is on.
  • Inspect tubing for kinks and straighten.
  • Replace filtration system filter.
  • Check refrigerator's water valve.
Reduced water flow
  • Partially kinked tubing
  • Partially clogged filter
  • Low household water pressure
  • Inspect and straighten tubing.
  • Replace filtration system filter.
  • Consult a plumber for water pressure issues.
Water leak at connections
  • Loose connections
  • Damaged O-rings or fittings
  • Improperly seated tubing
  • Turn off water supply and tighten connections.
  • Inspect fittings for damage; replace if necessary.
  • Ensure tubing is fully inserted into push-fit connectors.

Specifications

Model NumberFRFIM-605
ManufacturerFranke
Item Package Quantity1
Approximate Weight3 Lbs.
ComplianceNSF Standards 42, 53, 61 (Lead-Free)
ApplicationRefrigerator/Icemaker Hook-up Kit for Franke Triflow Filtration Systems

Warranty Information

Franke products are manufactured to high-quality standards and are backed by a manufacturer's warranty. For specific details regarding the warranty coverage for your FRFIM-605 component and associated Franke Triflow Filtration system, please refer to the warranty documentation included with your original purchase or visit the official Franke website.

Please retain your proof of purchase for warranty claims.

Customer Support

Should you require further assistance with the installation, operation, or troubleshooting of your Franke FRFIM-605 component, please contact Franke Customer Service. Our trained professionals are available to provide support and answer any questions you may have.

For contact information and additional resources, please visit the official Franke website or refer to the contact details provided in your original product packaging.

© 2024 Franke. All rights reserved. Information subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.