APC AP7532

APC Rack Mount PDU, Basic 120V/30A, (24) Outlets, 0U Vertical Rackmount (AP7532)

User Manual

1. Introduction

This manual provides essential information for the safe and efficient use of your APC Basic Rack Power Distribution Unit (PDU), model AP7532. This PDU is designed to distribute power outlets to rack-mount equipment, offering a reliable power solution for your data center or server room.

Key features of this PDU include:

2. Setup and Installation

The APC AP7532 PDU is designed for vertical mounting within a rack environment, specifically compatible with NetShelter VX rear channels for tool-less installation.

2.1 Unpacking

Carefully remove the PDU from its packaging. Inspect for any signs of damage during transit. Retain packaging for future transport or storage.

2.2 Mounting the PDU

This 0U PDU is designed for vertical installation. For NetShelter VX enclosures, it can be mounted without tools in the rear channel. For other rack types, ensure appropriate mounting hardware (not included) is used to securely fasten the PDU vertically within the rack space.

APC Basic Rack PDU AP7532, showing the full length of the unit with 24 outlets and power cord.

Figure 2.1: Front view of the APC AP7532 PDU, illustrating its vertical form factor and the arrangement of 24 NEMA 5-15 outlets along its length.

Diagram showing the vertical length of the APC PDU next to a human silhouette for scale, indicating a length of 76 inches (192 cm).

Figure 2.2: Scale diagram of the APC AP7532 PDU, highlighting its significant vertical length of 76 inches (192 cm) for rack integration.

2.3 Connecting Power

Connect the PDU's NEMA L5-30P input plug to a compatible 120V/30A power source. Ensure the power source is capable of handling the PDU's maximum load of 2.9 kW. Once the input power is connected, the PDU is ready to distribute power.

2.4 Connecting Equipment

Plug your rack-mount equipment into the twenty-four (24) NEMA 5-15 output receptacles on the PDU. Distribute the load evenly across the outlets to prevent overloading any single circuit or the PDU itself.

3. Operating Instructions

The APC Basic Rack PDU AP7532 operates as a pass-through power distribution unit. It does not feature individual outlet control or advanced monitoring capabilities. Power is continuously supplied to all connected outlets when the PDU is connected to a live power source.

4. Maintenance

Regular maintenance helps ensure the longevity and reliable operation of your PDU.

5. Troubleshooting

If you encounter issues with your APC PDU, refer to the following common troubleshooting steps:

If problems persist after attempting these steps, contact APC technical support for further assistance.

6. Specifications

AttributeDetail
Model NumberAP7532
BrandAPC
Product TypeBasic Rack Power Distribution Unit (PDU)
Input Voltage100V-120V
Input Current30A
Input ConnectorNEMA L5-30P
Output Receptacles24 x NEMA 5-15 Outlets
Power Capacity2.9 kW (2880 VA)
Mounting0U Vertical Rackmount
Cord Length9.8 feet (3 meters)
Product Dimensions (H x W x D)63.74 x 2.2 x 1.73 inches (161.9 x 5.6 x 4.4 cm)
Item Weight12.32 pounds (5.59 kg)
ColorBlack
Compliant StandardscUL Listed, CSA C22.2 No. 60950-1-03, UL 60950-1, UL Listed
Date First AvailableDecember 6, 2006
Country of OriginChina

7. Warranty and Support

For detailed warranty information, please refer to the warranty card included with your product or visit the official APC website. APC provides technical support and resources to assist with product inquiries, installation, and troubleshooting.

You can typically find support resources, FAQs, and contact information on the APC Support Website.

Related Documents - AP7532

Preview APC Switched Rack Power Distribution Unit Installation Guide
Installation and operation guide for APC Switched Rack Power Distribution Units (PDUs), covering features, installation, configuration, access, warranty, and support.
Preview APC SMT2200/SMT3000 PDU Replacement Installation Guide | Schneider Electric
This guide provides instructions for installing an optional replacement PDU panel for APC SMT2200 and SMT3000 UPS systems. It includes important safety messages, product handling guidelines, and step-by-step installation procedures.
Preview APC NetShelter Rack PDU Advanced & Rack Systems Product Guide
Comprehensive guide to APC NetShelter Rack PDUs, including the advanced 4-in-1 outlet models, basic, metered, switched, and metered-by-outlet options for data center power management. Features specifications, accessories, and rack system solutions.
Preview APC Rack Power Distribution Unit Installation Guide
Installation instructions for APC Rack Power Distribution Units (PDUs), including safety precautions, mounting procedures, and display interface information.
Preview APC NetShelter AR1000, AR1001, AR1100 Installation and User Manual
This manual provides detailed instructions for the installation, setup, and maintenance of American Power Conversion (APC) NetShelter rack enclosures, including models AR1000, AR1001, and AR1100. It covers product inventory, warnings, configuration, leveling, stabilization, and warranty information.
Preview APC Smart-UPS Installation Guide: SMT750RMI2UC to SMT3000RMI2UC
This guide provides installation instructions for APC Smart-UPS models SMT750RMI2UC, SMT1000RMI2UC, SMT1500RMI2UC, SMT2200RMI2UC, and SMT3000RMI2UC. It covers rack mounting, connections, and SmartConnect setup.