Honeywell WAVE-2F

Honeywell Ademco WAVE-2F Flush Mount Siren Instruction Manual

Model: WAVE-2F | Brand: Honeywell Ademco

1. Product Overview

The Honeywell Ademco WAVE-2F is a flush-mount siren designed for integration into security systems. Its compact and versatile design allows for discreet installation within a standard double-gang electrical box. The siren provides a high-decibel output to alert occupants and deter intruders, offering both steady and warble sound patterns.

Honeywell Ademco WAVE-2F Flush Mount Siren

Figure 1: Honeywell Ademco WAVE-2F Flush Mount Siren

2. Key Features

3. Installation

The WAVE-2F siren is designed for straightforward installation. It is intended to be flush-mounted within a standard double-gang electrical box.

3.1 Mounting

  1. Ensure power to the installation area is disconnected at the circuit breaker.
  2. Prepare a standard double-gang electrical box in the desired location.
  3. The siren features a hinged case design. Open the case to access the mounting holes and terminal block.
  4. Secure the siren's backplate to the electrical box using appropriate screws.

3.2 Wiring

  1. Connect the power supply wires (12VDC) to the easy terminal block connections inside the siren's case. Refer to your security system's wiring diagram for specific connections.
  2. Ensure all connections are secure and properly insulated.
  3. Close the hinged case of the siren.
  4. Restore power to the installation area.

4. Operation

The WAVE-2F siren operates in conjunction with your security alarm panel. When triggered by the alarm panel, it will emit a high-decibel sound.

4.1 Sound Patterns

The specific sound pattern (steady or warble) is typically selected via the wiring configuration or settings on your alarm control panel. Consult your alarm panel's manual for details on configuring siren output.

5. Maintenance

The WAVE-2F siren requires minimal maintenance. Regular checks can help ensure its continued reliable operation.

6. Troubleshooting

If the siren is not functioning as expected, consider the following:

If issues persist, contact a qualified security system technician.

7. Specifications

SpecificationValue
Model NumberWAVE-2F
BrandHoneywell Ademco
Current Draw500mA max @ 12VDC
Sound Pressure Output (Steady)106dB @ 12VDC, 1 meter
Sound Pressure Output (Warble)106dB @ 12VDC, 1 meter
Mounting TypeFlush Mount (Standard Double-Gang Electrical Box)
Item Weight7.2 ounces
Package Dimensions4.7 x 4.7 x 2.4 inches
ColorWhite
Control MethodRemote (via alarm panel)
Voltage12 Volts

8. Warranty and Support

For warranty information and technical support, please refer to the documentation provided with your complete security system or visit the official Honeywell Ademco website. Keep your purchase receipt for warranty claims.

Related Documents - WAVE-2F

Preview ADEMCO 5809 Rate-Of-Rise Heat Detector Installation and Setup Guide | Honeywell
Comprehensive installation and setup guide for the Honeywell ADEMCO 5809 wireless Rate-Of-Rise Heat Detector. Covers programming, testing, maintenance, and technical specifications for alarm systems.
Preview ADEMCO VISTA-10P / VISTA-10PSIA Security Systems Installation and Setup Guide
Comprehensive installation and setup guide for Honeywell ADEMCO VISTA-10P and VISTA-10PSIA security systems, covering wiring, mounting, programming, and testing procedures.
Preview ADEMCO VISTA Series Security Systems Installation and Operation Guide
Comprehensive installation and operation guide for ADEMCO VISTA Series security systems, including VISTA-20P, VISTA-20PSIA, VISTA-15P, and VISTA-15PSIA models. Covers mounting, wiring, system configuration, testing, and specifications.
Preview ADEMCO 5809 Rate-Of-Rise Heat Detector: Installation and Setup Guide
Comprehensive installation and setup guide for the Honeywell ADEMCO 5809 Rate-Of-Rise Heat Detector. Learn about general information, battery installation, programming, mounting, testing, maintenance, and specifications for this wireless alarm system component.
Preview Honeywell Vista 15SE and Uplink 5530M: Wiring and Programming Guide
Comprehensive guide for wiring and programming the Honeywell Vista 15SE alarm panel with Uplink's 5530M cellular communicator, including keypad programming steps and connection details.
Preview Honeywell HON-DACT-DS UL Listing Document: Features and Specifications
This Honeywell HON-DACT-DS UL Listing Document details the Digital Alarm Communicator Transmitter's features, installation, configuration, and limitations for fire alarm and emergency communication systems, emphasizing UL and NFPA compliance.