ARYTON-logo

ARYTON MAMBA Laser Source

ARYTON-MAMBA-Laser-Source-product

Specifications

  • Product Name: MAMBA | LASER SOURCE IP65 6 SERIES
  • Model: 6 SERIES
  • IP Rating: IP65
  • Manufactured by: 2 Rue de Vitruve, 91140 Villebon-sur-Yvette, France

ARYTON-MAMBA-Laser-Source-fig-26

Keep this manual for future needs.
Errors and omissions for all information given in this user manual are possible.
All information is subject to change without prior notice.

SAFETY INSTRUCTIONS

IMPORTANT SAFETY WARNINGS

  • This device has left the factory in perfect condition. In order to maintain this condition and to ensure safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual.
  • For safety reasons, please be aware that all modifications to the product are forbidden. We will not be liable for any damage or injury caused by installation, use, maintenance or service that not follow this manual.
  • In order to install, operate and maintain the lighting fixture safely and correctly we suggest that the installation and operation be carried out by qualified technicians and these instructions be carefully followed.

PHOTOBIOLOGICAL SAFETY

  • The light source of this product is based on laser diodes.
  • This product qualifies for the laser products safety standard IEC 60825-1:2014, edition 3, “part 4.4, Laser products designed to function as conventional lamps”, under which it is classified as
  • CLASS 1 LASER PRODUCT. Alternately evaluated under the standard IEC 62471-5:2015 “Photobiological safety of lamps and lamp systems”, the photobiological risk classification is assigned as RISK GROUP 3 (RG3).
    ARYTON-MAMBA-Laser-Source-fig-2

RISK GROUP 3

ARYTON-MAMBA-Laser-Source-fig-3

  • CAUTION! Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.
  • The US Food and Drug Administration (FDA) requires that the owner of the product be a holder of a valid FDA CDRH laser light show variance and operate the product in accordance with the terms of the variance. (variance is a “permit” issued by FDA). It requires the operator (if not the owner) of the product to be a legal employee of the variance holder and to have completed a laser safety training course and an operators training course.
  • This product is in conformity with performance standards for laser products under 21 CFR 1040, except with respect to those characteristics authorized by Variance Number FDA-2023-V-1465 effective (September 27, 2023)
  • The product is in excess of the Exempt Risk Group, the viewer-related risk is dependent upon how the user installs and uses the product.
  • Operators shall control access to the beam within the hazard distance or install the product at the height that will prevent spectators’ eyes from being within the hazard distance.
  • Hazard Distance (HD) is the distance from the projector’s nearest point of human access where the beam radiance or irradiance exceeds the applicable exposure limit.
  • The operators shall control the product to prevent human exposure to the luminaire(s) light within the HD. Hazard distances (according to different settings):
    • US HD (United States Hazard Distance) = 90 meters (312 feet).
    • Non US HD = 70 meters (230 feet).
    • Hazard Distance (worst case) is measured at full power and narrowest beam angle for 0.25 seconds.
    • However, do not illuminate personnel closer than this distance under any circumstances.
  • Do not operate with personnel exposure shorter than the declared hazard distance due to risk of skin or corneal burns.
  • This Laser Product is designated as Class 1 / RG3 during all procedures of operation.
  • Internal (embedded) laser parameters:
  • Laser Wavelengths: 449 – 461 nm.
  • Laser Power max: 70 W (at light engine aperture).
  • Beam Diameter: 26 mm.
  • Divergence: 910 mrad.
  • Emissions: 1.2 kHz, varying duty cycle: 0 — 97%.
  • Luminaire Wavelengths: 445 nm – 700 nm.
  • CAUTION! The user must not modify the unit or remove protective covers or housings except as required for service. The laser product is never to be operated if the unit is defective or the cover or seal is damaged.
  • Danger – class 4 laser light when open. Avoid eye or skin exposure to direct or scattered light.
  • No maintenance is required or allowed by the user.
  • Service is only to be performed by trained and authorized personnel. Consult service manual for laser safety procedures before opening unit.
  • As required by US state and federal OSHA requirements, maintenance and service is to be performed under the terms of ANSI Z136.1, “Safe Use of Lasers”. Wear laser safety eyewear when servicing the unit.
  • All laser light shows shall be under the direct and personal control of trained, competent operator(s). The operator(s) shall:
  • Be an employee of the variance holder who will be responsible for the training and the conduct of the operator.
  • Be located where all beam paths can be directly observed at all times.
  • Immediately terminate the emission of light show radiation in the event of any unsafe condition; or for outdoor shows, upon request by any air traffic control officials.
  • Hazard distances (HD) for all relevant viewer-related risk groups below RG3: Not Applicable. In no case expose personnel closer than the Hazard Distance indicated above.

CAUTION

ARYTON-MAMBA-Laser-Source-fig-4 ARYTON-MAMBA-Laser-Source-fig-5

GENERAL GUIDELINES
Damage caused by the disregard of this user manual is not subject to warranty The dealer and manufacturer will not accept liability for any resulting defects or problems.

  • Under no circumstances should the fixture be pointed at the sun. Sunlight, combined with the high efficiency lenses used in the product can cause significant damage to the fixture. Ensure the sealing rubber covers of powerCON TrueOne and XLR connectors are fitted properly when the device is not in use, to avoid water ingress.
  • Be aware that even when lens is not pointed directly at the sun damage may occur. It is best practice to ensure that the lens is pointed away from the sun, preferably in the opposite direction.
  • Always dry and clean your fixture before storing it for any length of time.
  • Never use any abrasive cleaning products on the fixture as this may damage the coating of the fixture impacting its anti-corrosion protection.
  • This product is intended for the following applications: trade show or convention, indoor arena, outdoor arena, outdoor unenclosed arena, stage, studio, theater, event, venues, theme parks, architecture and similar applications.
  • If the device has been exposed to temperature changes due to environmental conditions, do not power on immediately. The resulting condensation could damage the device. Leave the device powered off until it has reached room temperature.
  • Ensure the sealing rubber covers of powerCON and XLR connectors are fitted properly when the device is not in use, to avoid water ingress.
  • This device falls under protection-class I. Therefore, it is essential that the device be earthed.
  • If either lenses or display are damaged (damage may include cracks or gashes in the material) they must be replaced.
  • Electrical connections, such as replacing the power plug, must be performed by a qualified person.
  • Make sure that the available voltage is not higher than that which is stated in this manual.
  • Make sure the power cord is never crushed or damaged by sharp edges. If this should be the case, replacement of the cable must be done by an authorized dealer.
  • If the external flexible power cord of this device is damaged, it shall be exclusively replaced by the manufacturer or their service agent or a similar qualified person in order to avoid injury.
  • When the device is not in use or before performing maintenance or service, always disconnect the device from the mains. Only handle the power cord from the plug. Never pull the plug out of a socket by tugging the power cord.
  • When powered on for the first time, some smoke or smell may occur. This is caused by coating on metal parts when heated and is normal. If you are concerned, please contact your distributor.
  •  Do not focus the beam onto flammable surfaces. The minimum distance between the exiting lens of the device and the illuminated surface must be min. 35 m. The minimum distance from fixture head to combustible materials must be min. 0.1 m.(for personnel exposure distances, refer to the above mentioned Hazard Distances).
  • The projection system shall be securely mounted or immobilized to prevent unintended movement or misalignment. Beam masking will be provided as an inherent part of the system design to prevent overfilling of screens, beam stops, targets, etc.
  • This fixture is only allowed to be operated within the maximum alternating current as stated in the technical specifications in section 2 of this manual.
  • Handle the device with care, avoid shaking or using force when installing or maintaining the device.
  • If you use the quick lock cam when rigging the device, make sure the quick lock fasteners are located in the quick lock holes correctly and securely.
  • Operate the device only after having familiarized yourself with its functions. Do not permit operation by persons not qualified for operating the device. Most damage is the result of unprofessional operation.
  • Please use the original packaging if the device is to be transported.
  • The applicable temperature for the device is between -20  °C and 45  °C. Do not use the device outside of this temperature range. (Note: When the temperature detected by laser source between -20 °C and 0 °C, the fixture needs to wait for the heater to increase the internal temperature to be above 0  °C before illumination will occur.).

FEATURES

  • POWER SUPPLY
    • AC100-240 V~, 50/60 Hz
    • Power: 800 W maximum
  • OPTICS
    • Beam aperture: 0.7° to 15°
    • Fast motorised linear zoom
  • LIGHT SOURCE
    • Laser 500 W, White, Colour Temperature 10,000 K
    • Rated life (L70): up to 12,000 hours
  • MOVEMENT
    • Highly accurate positioning; moving-head operated via either 8- or 16-bit resolution
    • Pan and tilt automatic repositioning
    • Moving-head range: infinite pan and tilt rotation
  • COLOURS
    • Sophisticated CMY colour mixing
    • Static colour wheel with variable CTO, 15 complementary colour filters, 2 minus green filters, 2 multicolour filters and 3 coloured animation sections
  • GOBOS
    • One indexable rotating gobo wheels with 12 quartz glass gobos, plus open position
    • Adjustable-speed rotating gobo in both directions
    • Static multiposition gobo wheel with instant access to 80 metal gobos
  • FROST
    2 frost filters: one light, one heavy
  • EFFECTS
    • Monochromatic graphical animation effects wheel with continuous rotation in both directions
    • 12 combinable rotating and indexable prisms
  • DIMMER / STROBE
    • Electronic dimmer, allowing perfect light adjustment from 0 to 100% without colour variation
    • Strobe effect: 1 to 25 flashes per second
  • SOFTWARE FEATURES
    Local DMX addressing and optional parameters through its builtin
  • LCD control panel
    • Remote DMX addressing and optional parameters through a standard RDM DMX controller
    • Information menu including hour counter, temperature, software version
  • HARDWARE FEATURES
    • Graphic LCD display for addressing and special functions settings, with flip function
    • 5 menu buttons to set functions
    • Integrated wireless CRMX TiMo RDM receiver from LumenRadioTM
    • IP65 XLR-5 pin male and female connectors for DMX connection
    • IP65 RJ45 IN / OUT connectors for ArtNet connection
    • IP65 powerCON TRUE1 TOP male connector for power connection
  • CONTROL
    • DMX 512 protocol, through DMX cable or a wireless system
    • DMX-RDM compatible
    • ArtNet & sACN protocol through Ethernet cable
    • Local control panel, with IP65 LCD display
    • DMX mode (47 DMX channels)
  • COOLING SYSTEM
    • Advanced liquid cooling system
    • Self-adjusting variable speed fans for quiet operation (Auto mode)
    • Selectable ventilation user modes with a new Silent Mode
    • Safety protection against excess temperature
  • HOUSING
    IP65 protection rating (IP66 optional)
  • INSTALLATION
    • 2 Omega ¼ turn brackets
    • 4 ¼ turn mounting points
    • Safety cable attachment point
  • OPERATING PARAMETERS
    • Operating positions: all (device on floor or fixed to a support)
    • Maximum permitted: 45 °C (113 °F)
    • Minimum permitted: -20 °C (-4 °F)
    • Minimum usage distance: 35 m (114.83 ft)
  • COMPLIANCE
    CE, UKCA, ETL
  • SIZE
    • Product: 404 x 749 x 366 mm (l x h x d)
    • Foam: 680 x 640 x 500 mm (l x h x d)
  • WEIGHT
    Product: 41 kg

GETTING STARTED

UNPACKING
After unpacking, you will find the following items in the package:

  • MAMBA fixture 1
  • User Information manual 1
  • Power Cable 1
  • Omega Bracket 2

PLACEMENT OF LABELS
Please check and read carefully the labels on the fixture before using:

ARYTON-MAMBA-Laser-Source-fig-6 ARYTON-MAMBA-Laser-Source-fig-7

FIXTURE OVERVIEW

ARYTON-MAMBA-Laser-Source-fig-8

  1. Front Lens
  2. Tilt Lock
  3. Handle
  4. NFC
  5. Display
  6. Left-button
  7. Down-button
  8. Center-button
  9. Right-button
  10. Up-button
  11. Pan lock
  12. Handle
  13. Power In
  14. Valve
  15. RJ45 In
  16. RJ45 Out
  17. DMX In
  18. DMX Out

UNLOCK THE PAN AND TILT BEFORE USING

ARYTON-MAMBA-Laser-Source-fig-9

Release the Tilt lock by pulling it out and turn 90°.

ARYTON-MAMBA-Laser-Source-fig-10

Release the Pan lock by pulling it to the right side.

INSTALLATION INSTRUCTIONS – RIGGING THE FIXTURES

CAUTION
Please consider the respective national norms during the installation. the installation must only be carried out by a qualified person.

  • The installation of the effect has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation.
  • The installation must always be secured with a secondary safety attachment, e.g. an apwpropriate safety rope.
  • Never stand directly below the device when mounting, removing or servicing the fixture.
  • The operator has to make sure the safety relating and machine technical installations are approved by an expert before taking the device into operation for the first time.
  • These installations have to be approved by a skilled person once a year.

RIGGING USING THE OMEGA BRACKETS

  • Fix the clamp to the bracket by tightening the M12 nut and bolt to the bracket through the Ф13 hole in the middle of the bracket. Insert the quick-lock fasteners of the first Omega holder into the respective holes on the bottom of the device. Tighten the quick-lock fasteners fully clockwise.
  • Install the second Omega holder.
  • Pull the safety cable through the holes on the bottom of the base and over the trussing system or another suitable rigging point. Insert the end into the carabiner and tighten the safety screw.

CAUTION
This step is very important to ensure safe rigging of the fixture.

ARYTON-MAMBA-Laser-Source-fig-11

  1. Omega bracket
  2. Clamp
  3. Safety rope
  4. Quick-lock fastener

RIGGING DRAWINGS

The fixtures can be installed by sitting on floor, hanging on truss upside down (on ceiling) or hanging vertically (on wall), as shown on the drawing below:

ARYTON-MAMBA-Laser-Source-fig-12

  • Be sure this fixture is kept at least 0.1 m away from any flammable materials (decoration etc.).
  • Always use and install a supplied safety cable as a safety measure to prevent accidental damage and/or injury in the event the clamp fails.
  • Rig the projector high enough to provide clearance for people who may walk beneath the beam path or establishing a restricted access area that extends beyond the beam hazard distance.
  • CAUTION! Please DO NOT let other external intense lights to shine through the fixture front lens, it may cause significant internal damages!
  • When install fixture outdoor at day time (with power off), please make sure that the fixture front lens is NOT facing the sun.
  • When use fixture outdoor at day time (with power on), please avoid fixture front lens facing the sun.
  • When fixture is on standby outdoor at day time (with power ON and no DMX signal), please make sure the “sun protection” mode is ON (default).

CONNECTIONS – CONNECTING POWER AND SIGNAL CABLES

POWER CONNECTION

ARYTON-MAMBA-Laser-Source-fig-13

  • Connect the power cable to the “Power In” socket of the fixture: Insert the power cable connector and turn clockwise until it clicks to lock.
  • Connect the power cable plug to the mains: AC100-240 V~, 50/60 Hz, Power 800 W.

DMX-512 / ART-NET CONTROL CONNECTION
Connect the provided male side of the XLR cable to the female XLR output of your controller and the female side of the XLR cable to the male XLR input of the device. You can connect multiple devices together in a serial fashion. The cable needed should be two core, screened cable with XLR input and output connectors. Please refer to the diagram below.

ARYTON-MAMBA-Laser-Source-fig-14

DMX-512 CONNECTION WITH DMX TERMINATOR
For installations where the DMX cable has to run over a long distance or is in an electrically noisy environment, such as in a discotheque, it is recommended to use a DMX terminator. This helps in preventing corruption of the digital control signal caused by electrical noise. The DMX terminator is an XLR plug with a 120 Ω resistor connected between pins 2 and 3, which is then plugged into the output (female) XLR socket of the last fixture in the chain. Please see illustrations below.

ARYTON-MAMBA-Laser-Source-fig-15

DEVICE DMX START ADDRES SETTING
All fixtures should be given a DMX starting address when using a DMX signal, so that the correct fixture responds to the correct control signals This digital starting address is the channel number from which the fixture starts to “listen” to the digital control information sent out from the DMX controller. The allocation of this starting address is achieved by setting the correct address number on the display located on the base of the device. You can set the same starting address for all fixtures or a group of fixtures, or set different addresses for each fixture individually. If you set the same address on all devices, all the devices will start to “listen” to the same control signal from the same channel number. In other words, changing the settings of one channel will affect all the fixtures simultaneously. If you set a different address, each unit will start to “listen” to the channel number you have set, based on the quantity of control channels of the unit. That means changing the settings of one channel will affect only the selected device.

In the case of the moving head, in 46 channel mode, you should set the starting address of the first unit to 1, the second unit to 47 (46 + 1), the third unit to 93 (46+47), and so on.

DISPLAY SETTINGS OPERATION
The fixture offers LCD Display and Buttons for setting display menus, you can use the buttons to set or check the Address, Mode, Options, Test, Info and Preset menus.

ARYTON-MAMBA-Laser-Source-fig-16

After accessing the submenu in edit mode, if no operation, it will automatically exit to the main menu after 15 seconds from the last button operation. When the fixture is powered on and the signal is connected, after 5 minutes, the display will switch off automatically.

USING THE DISPLAY MENUS
Double click to activate display, then on the main menu double click to enter into the following menus, click the up button or down button to browse and select the desired menus:

ARYTON-MAMBA-Laser-Source-fig-17

NFC
When the fixture is powered on, you can use a NFC smartphone installed with the Ayrton NFC App to scan the NFC tag area of the fixture to read some of the information or settings inside the display menu, such as product name, software version, UID, DMX Start Address, Universe, User Mode, Options, Information, etc. You can also change some of the settings and push to write inside the fixture menu.
When the fixture is not powered on, you can still use the App to read the NFC info and write the settings into the NFC tag, the written data will be automatically synchronized into the fixture menu at next time the fixture is powered on.
Link to download the application: https://qrstud.io/ayrtonnfc

Note:

  • Before using, make sure there is NFC function on your smartphone and it is activated. Download and install the Ayrton NFC App;
  • The NFC tag on the fixture is right under the LCD window;
  • The NFC reader area vary on different smartphones, identify the correct area on your smartphone before scanning the NFC tag on the fixture;
  • When scanning, make sure the NFC reader area of your smartphone close enough to the LCD window and hold still the smartphone for 3 seconds until reading successfully.

DMX PROTOCOL
Scan the QR code on the cover page to download the DMX CHART.

SAFETY SETTINGS
For safety purposes, before the operator begins to control the fixture remotely, the operator must pre-define, from a computer (MAC or PC) App a safety (blanking) zone which prevents operations above the MPE (Maximum Permissible Exposure) within the safety zone(or other). The safety (blanking) zone should be set to include any area in which the fixture may be pointed where there is a reasonable expectation of the public being present. Where the operator determines there will be no members of the public present or no members of the public present within the Hazard Distance of the product (please see table below), no safety (blanking) zone is needed to be set.

  • US HD (United States Hazard Distance) = 90 meters (312 feet).
  • Non US HD = 70 meters (230 feet).
  • Hazard Distance (worst case) is measured at full power and narrowest beam angle for 0.25 seconds.
  • However, do not illuminate personnel closer than this distance under any circumstances.

BLANKING ZONE SETTINGS

ARYTON-MAMBA-Laser-Source-fig-18

Steps to set blanking zone: please refer to the“Blanking zone setting guide”

SAFETY PROTECTION
This fixture had been designed with Safety Protection feature: When error occurs, not only the light output itself will be cut immediately, but also the CMY filters, Colour filter and Frost filter will be brought into the light path and the Zoom will go to max immediately to block the light output lens to provide multi-protection layers.

SAFETY MONITORING SYSTEM – SEPARATE REDUNDANCY CONTROL
This fixture had been designed with a Safety Monitoring System with Separate Redundancy Control, the failure safety system shuts down or dims to safe level immediately when any safety monitored value is reported outside of expected value: When light output (as measured by current) is out of expected range; when Pan or Tilt are forced from proper location, or do not arrive at proper location; when zoom is forced from proper location, or do not arrive at proper location.

CONTROLS AND FUNCTIONS

PAN AND TILT MOVEMENT, DMX CHANNELS 1-7

DIMMER INTENSITY (USE WITH STROBE CHANNEL AT FULL), DMX CHANNELS 8-10

ARYTON-MAMBA-Laser-Source-fig-19

ZOOM (USE WITH FOCUS CHANNEL), DMX CHANNELS 14-17

ARYTON-MAMBA-Laser-Source-fig-20

CMY, DMX CHANNELS 23-28

ARYTON-MAMBA-Laser-Source-fig-21

COLOUR WHEEL WITH CTO, DMX CHANNELS 11-12, 21-22

ARYTON-MAMBA-Laser-Source-fig-22

COLOUR WHEEL

COLOUR WHEEL
1 Red 12 Dark Green
2 Blue 13 Dark Amber
3 Orange 14 Medium Blue
4 Green 15 Oklahoma Yellow
5 Pink 16 Multicolour #1
6 Yellow 17 Multicolour #2
7 Velvet Green 18 Minus Green ¼
8 Amber 19 Minus Green 1⁄2
9 Light Blue 20 Multicolour Animation
10 Follies Pink 21 Red/Yellow Animation
11 Slate Blue 22 Green/Yellow Animation

ROTATING GOBOS, DMX CHANNELS 29-31

ARYTON-MAMBA-Laser-Source-fig-23

GOBO WHEEL 1

ARYTON-MAMBA-Laser-Source-fig-28 ARYTON-MAMBA-Laser-Source-fig-29

ARYTON-MAMBA-Laser-Source-fig-24

GOBO WHEEL 2

GOBO WHEEL 2
Static Gobo
1 302 80% Iris Beam 41 353 Four Lines V
2 304 60% Iris Beam 42 330 Square Beam
3 306 40% Iris Beam 43 363 Rubik Cube
4 308 20% Iris Beam 44 437 Split Cross
5 312 Dot Line 2 45 334 Square Beam 9
6 326 Dot Triangle 3 46 320 Dot Ring 6
7 328 Dot Square 4 47 321 Dot Ring 7
8 319 Dot Ring 5 48 413 Split Circle 6
9 257 Zig Zag Light 49 324 Dot Mix
10 135 Vortex Light 50 340 Triangle Beam
11 110 Spiral 51 374 Compass 4
12 118 Helix 5 52 346 Star Line 5
13 424 Triangle Beam 53 345 Star 5
14 263 Daisy 54 378 Star 8
15 373 Nested Star 55 380 Star 10
16 368 Square Ring 8 56 382 Star 12
17 439 Circular Saw 4 57 262 Arrow Ring 6
18 099 Waves Light 58 117 Helix 3
19 274 Prison Bars 4 59 342 Five Spokes
20 269 Ink Stain 60 261 Arrow Ring 3
21 260 Arrows 61 435 Nested Cross
22 265 Iris 8 62 421 Split Square 1
23 326 Dot Mix 8 63 431 X Cross
24 290 Quarter Beam NE 64 348 Tilde
25 291 Quarter Beam SE 65 188 Mirror Ball 9
26 292 Quarter Beam SW 66 417 Split Target
27 293 Quarter Beam NW 67 422 Split Square 2
28 296 Half Beam Up 68 427 Split Triangle 2
29 295 Half Beam Down 69 411 Split Circle 2
30 298 Half Beam Left 70 450 Number 0
31 299 Half Beam Right 71 451 Number 1
32 418 Crash Test Icon 72 452 Number 2
33 341 Split Triangle 4 73 453 Number 3
34 426 Split Triangle 1 74 454 Number 4
35 419 Iron Ball Light 75 455 Number 5
36 351 Vertical Line 76 456 Number 6
37 350 Bold Line 77 457 Number 7
38 371 Square Line 3 V 78 458 Number 8
39 370 Square Line 3 H 79 459 Number 9
40 353 Four Lines H      

PRISMS (WITH FROST), DMX CHANNELS 33-45

ARYTON-MAMBA-Laser-Source-fig-25

ARYTON-MAMBA-Laser-Source-fig-1

2 Rue de Vitruve – 91140 – Villebon-sur-Yvette – France

Frequently Asked Questions

Q: Can this product be used for household purposes?

A: No, this product is not intended for household use due to photobiological safety concerns. It should be operated by qualified personnel only.

Q: What is the recommended distance to prevent hazardous radiation exposure?

A: Refer to the manual for the Hazard Distance (HD) specific to this product. Operators should ensure spectators’ eyes are outside the hazard distance or install the product at an appropriate height.

Documents / Resources

ARYTON MAMBA Laser Source [pdf] Instructions
MAMBA Laser Source, MAMBA, Laser Source, Source

References

Leave a comment

Your email address will not be published. Required fields are marked *