OmniAC30 All Weather Outdoor Multi Tech Smart Standalone Terminal
“
Product Information
Specifications
- Product: OmniAC30
- Installation Guide Version: 1.5
- Installation Environment: Indoors with specific
recommendations - Power Input: 12V
- Network Connection: Ethernet
- Supported Connections: Wiegand Reader, RS485, Door Sensor, Exit
Button, Lock Relay, Printer
Product Usage Instructions
Device Installation
With Backplate:
- Attach the mounting template sticker to the wall and drill
holes accordingly. - Fix the Backplate on the wall using wall mounting screws.
- Attach the device to the Backplate.
- Fasten the device to the Backplate with a security screw.
With Back Cover:
- Attach the mounting template sticker to the wall and drill
holes accordingly. - Fix the Back Cover on the wall using wall mounting screws.
- Attach the device to the Back Cover.
- Fasten the device to the Back Cover with a security screw.
Wiring Diagram
Power Connection: Use a recommended AC Adapter
with higher current ratings if sharing power with other
devices.
Ethernet Connection: Connect the device and
computer software over an Ethernet cable. Set IP addresses in the
same network segment for LAN connection.
Wiegand Reader and RS485 Connection: Follow the
provided wiring diagram for proper connection of 485 Reader,
Wiegand Reader, Access Controller, and related components.
Door Sensor, Exit Button, Auxiliary Connection:
Connect components as per the provided instructions for proper
functionality.
Lock Relay Connection: Connect the lock system
based on whether it is Normally Opened or Normally Closed. Ensure
proper power sharing with the lock if needed.
Printer Connection: Connect the printer using
the provided RS232 Cable for communication.
Frequently Asked Questions (FAQ)
Q: Can I use any AC Adapter for power connection?
A: It is recommended to use an AC Adapter with higher current
ratings if sharing power with other devices.
Q: What IP address should I set for Ethernet connection?
A: Set the default IP address to 192.168.1.130 with a subnet
mask of 255.255.255.0 for proper Ethernet connection.
Q: How should I connect the lock relay for different types of
locks?
A: Follow the provided instructions for connecting Normally
Opened (NO) or Normally Closed (NC) locks appropriately based on
the system configuration.
“`
OmniAC30
Installation Guide
Version: 1.5
How to Install the Device?
Installation Environment Please refer to the following recommendations for installation.
window
6.5ft 10ft
KEEP DISTANCE
AVOID GLASS REFRACTION
Device Installation
AVOID DIRECT SUNLIGHT
AND EXPOSURE
KEEP EFFECTIVE DISTANCE 0.3-2m
With Backplate :
1. Attach the mounting template sticker to the wall, and drill holes according to the mounting paper.
2. Fix the Backplate on the wall using wall mounting screws.
3. Attach the device to the Backplate.
4. Fasten the device to the Backplate with a security screw.
1
2
53.15″ / 1.35m
3
4
1
With Back Cover: 1. Attach the mounting template sticker to the wall, and drill holes according
to the mounting paper. 2. Fix the Back Cover on the wall using wall mounting screws. 3. Attach the device to the Back Cover. 4. Fasten the device to the Back Cover with a security screw.
1
2
49.21″ / 1.25m
3
4
Note: Features and parameters with mark are not available in all devices.
2
Wiring Diagram
Power Connection
Recommended AC Adapter
1) 12V ± 10%, at least 3A.
2) To share the power with
other devices, use an
AC Adapter with higher
12V
current ratings.
Ethernet Connection Connect the device and computer software over an Ethernet cable. As shown in the example below:
PC
Default IP address: 192.168.1.201 Subnet mask: 255.255.255.0
IP address: 192.168.1.130 Subnet mask: 255.255.255.0
Click on [COMM.] > [Ethernet] > [IP Address] , input the IP address and click on [OK]. Note: In LAN, the IP addresses of the server (PC) and the device must be in the same network segment when connecting to the software.
3
Wiegand Reader and RS485 Connection
485B 485A GND 12V-OUT WD1-OUT WD0-OUT IWD1 IWD0 GND 12V-OUT
485 Reader
485485+ GND +12V
WD1 WD0 GND +12V
Wiegand Reader
Access Controller
GND WD1 WD0
Door Sensor, Exit Button, Auxiliary Connection
AUX SEN GND BUT NO COM NC ALARMALARM+
Smoke Detector
NO COM
Detector Power
Door Sensor
Alarm Alarm Power
ExitButton
4
Lock Relay Connection
The system supports Normally Opened Lock and Normally Closed Lock. The NO LOCK (normally unlocked when power-on) is connected with ‘NO’ and ‘COM’ terminals, and the NC LOCK (normally locked when power-on) is connected with ‘NC’ and ‘COM’ terminals. Take NC Lock as an example below:
1)Device not sharing power with the lock
Lock
AUX SEN GND BUT NO COM NC ALARMALARM+
+12V GND
DC 12V
FR107
AC Adapter DC12-3A
12V
2)Device sharing power with the lock
AUX SEN GND BUT NO COM NC ALARMALARM+
+12V GND
5
Lock
FR107
DC 12V
AC Adapter DC12-3A
12V
Printer Connection
12V-OUT GND GND
RS232-RXD RS232-TXD
RS232 Cable
Printer
6
Copyright © 2025 ARMATURA LLC. All rights reserved.
Documents / Resources
![]() |
ARMATURA OmniAC30 All Weather Outdoor Multi Tech Smart Standalone Terminal [pdf] Installation Guide IG_EN v1.5, 20241226, 105X145mm, OmniAC30 All Weather Outdoor Multi Tech Smart Standalone Terminal, OmniAC30, All Weather Outdoor Multi Tech Smart Standalone Terminal, Outdoor Multi Tech Smart Standalone Terminal, Multi Tech Smart Standalone Terminal, Tech Smart Standalone Terminal, Smart Standalone Terminal, Standalone Terminal |