ARATEK TE100 Front End Computing Intelligent Network Camera

Overview
The TrustEye Series TE100 Smart Camera is an AI-enabled smart network camera with a built-in NPU for intelligent video analytics. It is designed for easy deployment, simple operation, and strong environmental adaptability, with local preview and remote viewing/control via management platforms.
Specifications
| Processor | Domestic quad-core ARM CPU, 2 TOPS (INT8) |
| Maximum image size | 3840×2160 |
| Main stream | 8MP (3840×2160) @30fps (default); 6MP (3072×2048) @30fps; 4MP (2560×1440) @30fps; 4MP (2592×1536) @30fps; 1080P (1920×1280) @30fps; 720P (1280×720) @30fps |
| Sub stream | 720P (1280×720) @30fps (default); D1 (720×480) @30fps; CIF (352×288) @30fps |
| Triple stream | 720P (1280×720) @30fps (default); D1 (720×480) @30fps; CIF (352×288) @30fps |
| Video compression | H.264 / H.265 / H.264+ / H.265+ / MJPEG |
| H.264 profile | Baseline / Main / High |
| H.265 profile | Main |
| Bitrate control | Variable bitrate, Constant bitrate |
| ROI | Supported |
| Memory | 1GB |
| Storage | EMMC, 8GB |
| SD-card storage | Max 256G (ensure SD write speed ≥ 6MB/s) |
| Network protocols | TCP/IP, ICMP, HTTP, HTTPS, DHCP, DNS, DDNS, RTP, RTSP, NTP, SMTP, PPPoE, SNMP, QoS (IPv6 supported) |
| Power | DC: 12V (reverse power supply supported; can be used for powering audio pickup). POE: IEEE 802.3af; supports power modes 1236 and 4578; POE power 15.4W with isolation. |
| Operating temperature & humidity | -30°C to +60°C, max 95% RH |
Quick Setup
- Wired connection: Connect the camera and a computer via a switch or router. Ensure the switch/router supports DHCP.
- Search and modify IP address: Open IPCamera Tool-V1.3.exe. Click Start Search to detect online cameras. Select the target camera, set the camera IP and parameters in the upper-right area, then click Apply to Device to configure a static IP.
- User password: Open a web browser, enter the camera IP address in the address bar, log in to the management page, and follow the on-screen guidance to modify the user password.
Features
- Front-End Computing: The camera is designed to perform selected processing tasks directly at the surveillance endpoint. This can reduce the amount of raw data that must be continuously transmitted to a central server.
- Intelligent Video Monitoring: The TE100 supports intelligent network surveillance applications and can work as part of a larger video security system.
- Network-Based Operation: Video and camera information are transmitted over an IP network, allowing integration with compatible network recorders, monitoring stations, and management software.
- Real-Time Surveillance: The camera provides continuous live video monitoring for security, supervision, and incident review applications.
- Edge Processing Capability: Intelligent processing at the camera can improve event-response efficiency by analyzing selected video information close to the point of capture.
- Centralized Management Compatibility: Multiple compatible cameras may be managed through a supported video management platform or network recording system.
- Event-Based Monitoring: Depending on system configuration, intelligent functions may be used to identify specified events and generate corresponding notifications or records.
- Flexible Installation: The camera can be positioned to monitor entrances, corridors, work areas, storage locations, building perimeters, and other surveillance zones.
- Digital Video Storage Compatibility: Recorded footage can be stored through a compatible NVR, server, or surveillance management platform.
- Continuous System Operation: The camera is intended for extended security monitoring when correctly powered, connected, configured, and maintained
The TrustEye Series TE100 Smart Camera is a front‑end computing intelligent network camera developed by Aratek. It integrates an NPU computing unit to deliver AI video analytics capabilities. It is widely deployed in smart communities, smart parks, smart campuses, smart construction sites, transparent kitchen projects, cold‑chain supervision, and other scenarios. Featuring simple deployment, easy operation, and strong environmental adaptability, this camera adopts an industrial‑grade design to suit diverse operating environments. Compliant with the GB28181 standard, it offers great compatibility. Users can perform local preview as well as remote control and viewing via management platforms. Rich interfaces enable flexible integration, and a standard Open‑API is provided for third‑party system integration.
Network Configuration
Wired Network Connection
Connect the camera and computer via a switch or router. The switch or router shall support DHCP.
Search and Modify IP Address
- Procedures to search and modify the IP address of the network camera: 1. Click “IPCamera Tool‑V1.3.exe” and open the configuration tool.

- Click “Start Search” to detect online IPC cameras.

- To configure a static IP: select the target camera in the left device list, set the camera IP and other parameters in the upper-right area, then click “Apply to Device”.

User Password Setting
Open the web browser, input the camera IP address in the address bar to log in to the management page. Follow the graphic guidance to modify user password.
Packing List
| No. | Item | Quantity | Description |
|---|---|---|---|
| 1 | IPC Camera Main Unit | 1 | Main body of intelligent IPC camera. |
| 2 | Mounting Position Sticker | 1 | Positioning for wall-mount drilling. |
| 3 | User Manual | 1 | Quick setup instructions for the product. |
| 4 | Certificate of Conformity | 1 | Factory inspection qualification certificate. |
| 5 | Warranty Card | 1 | For user information, purchase information, maintenance records, and warranty clauses. |
How to Use
- Step 1: Power On the Camera:
Confirm that the camera is properly mounted, connected to the network, and receiving the correct power supply. Allow the unit to complete its startup process. - Step 2: Access the Camera:
Open the compatible monitoring software, NVR interface, or supported network management system and locate the TE100 camera. - Step 3: Log In:
Enter the authorized administrator or user credentials. Change any default password during initial installation if required by the system. - Step 4: View Live Video:
Open the live-view function and confirm that the video image is clear, properly oriented, and covering the required surveillance area. - Step 5: Configure Image Settings:
Adjust available image parameters such as brightness, contrast, exposure, or other supported settings according to the installation environment. - Step 6: Configure Recording:
Select the required recording method through the connected NVR or management platform. Recording may be continuous, scheduled, or event-based depending on system capabilities. - Step 7: Configure Intelligent Functions:
Enable only the intelligent analysis or event-detection functions supported by the installed camera and management system. Define the required monitoring areas and event rules where applicable. - Step 8: Configure Alerts:
Set compatible alarm or notification functions if required. Test the configured event conditions to confirm that alerts are generated correctly. - Step 9: Review Recorded Video:
Use the playback interface of the connected recording system to locate and review stored footage by date, time, or event. - Step 10: Monitor System Status:
Regularly check camera connectivity, image quality, recording status, storage condition, and system notifications
Safety Tips
- Use only the power source and connection method specified for the TE100 camera.
- Disconnect power before installing, removing, or servicing the camera.
- Do not install the camera on an unstable wall, loose panel, or weak mounting surface.
- Use suitable anchors and fasteners for the installation surface.
- Do not expose the camera to water unless the specific installed unit is confirmed to have an appropriate environmental protection rating.
- Do not operate the camera with damaged cables, connectors, or housing.
- Do not touch electrical connections with wet hands.
- Keep network and power cables away from sharp edges and high-temperature surfaces.
- Do not open or modify the camera housing unless servicing is performed by qualified personnel.
- Avoid pointing the camera directly toward extremely intense light sources for extended periods.
- Do not cover ventilation areas if the camera housing includes thermal-management openings.
- Keep the camera away from corrosive chemicals and excessive dust.
- Do not use aggressive solvents, gasoline, or abrasive cleaners on the housing or optical surfaces.
- Protect the camera from strong impact and excessive vibration.
- Ensure that cables are routed safely and do not create a trip or snagging hazard.
- Use surge protection where appropriate for the surveillance network and power installation.
- Use secure passwords and restrict administrative access to authorized users.
- Change factory-default credentials during initial configuration when applicable.
- Keep camera firmware and management software updated using approved software sources.
- Follow applicable privacy, surveillance, and data-protection requirements when installing and operating the camera.
FCC Statement
- This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
- Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Camera does not power on | No power or incorrect connection | Check the approved power source, cable, and connector |
| Camera is not detected on network | Network cable disconnected or incorrect network settings | Check Ethernet connection and verify network configuration |
| No live video | Camera offline or communication failure | Confirm camera status, network connection, and monitoring software settings |
| Image is blurred | Lens surface dirty or camera focus/position incorrect | Clean the viewing surface and adjust the camera position or supported image settings |
| Image is too dark | Insufficient lighting or incorrect exposure settings | Improve lighting or adjust supported exposure settings |
| Image is too bright | Strong light source or excessive exposure | Reposition the camera or adjust supported image parameters |
| Video freezes | Network congestion or unstable connection | Check network bandwidth, switch connection, and cable condition |
| Recording is unavailable | NVR or server storage not configured | Check recording schedule, storage capacity, and recording-system settings |
| Intelligent detection does not operate | Detection feature disabled or incorrectly configured | Enable the supported function and verify detection zones and rules |
| Frequent false alarms | Detection sensitivity or monitoring area unsuitable | Adjust supported event sensitivity and redefine monitoring zones |
| Camera disconnects intermittently | Loose cable, unstable power, or network interruption | Inspect power and network connections and test the network |
| Incorrect date or time | Time synchronization not configured | Set the correct time zone and configure supported time synchronization |
| Cannot log in | Incorrect credentials or account settings | Verify username and password or use the approved administrator recovery procedure |
| Poor nighttime image | Insufficient illumination or obstructed viewing area | Check available lighting and remove objects blocking the monitored area |
| Camera overheats | Poor ventilation or unsuitable installation environment | Improve airflow and ensure the operating environment is within the permitted range |
| Camera settings are lost | Configuration reset or incorrect save procedure | Reconfigure the device and save or back up settings through the management system |
Documents / Resources
![]() | TE100 Front End Computing Intelligent Network Camera |
![]() | TE100 Front End Computing Intelligent Network Camera |
References
- User Manualmanual.tools