Anolis logoARCDOT
INSTALLATION INSTRUCTIONS
Anolis ARCDOT LED Lighting -

ARCDOT LED Lighting

BLAUPUNKT MS46BT Bluetooth CD-MP3 player with FM and USB - icon 3 Fixture must be installed by a qualified electrican in accordance with all national and local electrical and construction codes and regulations.

Version 1- with two supply cables Version 2- with one supply cable and T-connector
Anolis ARCDOT LED Lighting - supply cables Anolis ARCDOT LED Lighting - with one supply cable

STEP 1 INSTALL HOUSING

Anolis ARCDOT LED Lighting - INSTALL HOUSING

Drill holes to the mounting surface according to base plate holes spacing. Mount base plate via fasteners to the surface, taking care not to over tighten them.

STEP 2 INSTALL LUMINAIRE

Anolis ARCDOT LED Lighting - LUMINAIRE

Snap the luminaire on mounted base plate.Anolis ARCDOT LED Lighting - tighten them

Turn with luminaire in clockwise direction, untill you feel it is mounted well.

Anolis ARCDOT LED Lighting - luminaire position

Ensure the luminaire position with M5x5 bolt.

STEP 3 CONNECTION LTUMINAIRE

Before ArcDots are connected to power source, you have to connect the Active Terminator on the last luminaire in the row.
That is necessary for correct identification of every single ArcDot and this has to be done for setup of every ArcDots row.
You can change the Active Terminator box for Passive Terminator box, when the set up is finished.

Anolis ARCDOT LED Lighting - LTUMINAIRE

BLAUPUNKT MS46BT Bluetooth CD-MP3 player with FM and USB - icon 3 Every ArcDot line has to be terminated with the active/passive terminator

Version 1- with two supply cables

Anolis ARCDOT LED Lighting - cables

Version 2- with one supply cable and T-connector

Anolis ARCDOT LED Lighting - connector

The minimum cable lenght of 0.3m between two T-connectors has to be kept in case that the ArcDot sorting is done manually from the ArcPixel Power menu.
BLAUPUNKT MS46BT Bluetooth CD-MP3 player with FM and USB - icon 3 Maximum length between the Arc Power and the last ArcDot must not exceed 100 meters. Do not connect or disconnect the ArcDot strings with the ArcPixel Power/ArcPower Unit Pixel energized.

Anolis ARCDOT LED Lighting - There must beConnect the ArcPixel row into ArcPixel Power. There must be a ferrite filter placed on every ArcPixel Power output to avoid high frequency noises in the circuit.

Anolis ARCDOT LED Lighting - Unit Pixel

Install terminal blocks on cable and connect it to the ArcPower Unit Pixel.

ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic
Tel.: +420 571 751 500
E-mail: info@anolis.eu
www.anolislighting.com
VERSION 1.0 / 05_2021

Documents / Resources

Anolis ARCDOT LED Lighting [pdf] Instruction Manual
ARCDOT LED Lighting, ARCDOT, LED Lighting

References

Leave a comment

Your email address will not be published. Required fields are marked *