Installation Instructions ArcDot v1 May 2021
INSTALLATION INSTRUCTIONS ARCDOT
Fixture must be installed by a qualified electrican in accordance with all national and local electrical and construction codes and regulations.

ArcDot

ArcDot Optic

ArcDot Flash

Version 1- with two supply cables 1A Side connection

Version 2- with one supply cable and T-connector 2A Side connection

1B Bottom connection

2B Bottom connection

ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: info@anolis.eu | www.anolislighting.com

VERSION 1.0 / 05_2021

1

INSTALLATION INSTRUCTIONS ARCDOT
STEP 1 INSTALL HOUSING

STEP 2 INSTALL LUMINAIRE
1

Drill holes to the mounting surface according to base plate holes spacing. Mount base plate via fasteners to the surface, taking care not to over tighten them.
2

Snap the luminaire on mounted base plate. 3

Turn with luminaire in clockwise direction, untill you feel it is mounted well.
STEP 3 CONNECTION LTUMINAIRE
Before ArcDots are connected to power source, you have to connect the Active Terminator on the last luminaire in the row. That is necessary for correct identification of every single ArcDot and this has to be done for setup of every ArcDots row. You can change the Active Terminator box for Passive Terminator box, when the set up is finished.

Ensure the luminaire position with M5x5 bolt.

ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: info@anolis.eu | www.anolislighting.com

VERSION 1.0 / 05_2021

2

INSTALLATION INSTRUCTIONS ARCDOT
Version 1- with two supply cables

Version 2- with one supply cable and T-connector

The minimum cable lenght of 0.3m between two T-connectors has to be kept in case that the ArcDot sorting is done manually from the ArcPixel Power menu.
Maximum length between the Arc Power and the last ArcDot must not exceed 100 meters. Do not connect or disconnect the ArcDot
strings with the ArcPixel Power/ArcPower Unit Pixel energized.

1A

ArcPixel Power

1B

ArcPower Unit Pixel

Connect the ArcPixel row into ArcPixel Power. There must be a ferrite filter placed on every ArcPixel Power output to avoid high frequency noises in the circuit.

Install terminal blocks on cable and connect it to the ArcPower Unit Pixel.

ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: info@anolis.eu | www.anolislighting.com

VERSION 1.0 / 05_2021

3

