Altronix T2MK3F4Q Lore Plus Technology
FAQ
Q: Can I use Trove1 with more than 8 doors?
A: No, Trove1 is designed to accommodate up to 8 doors only. For more doors, consider Trove2 or Trove3 series.
Q: Are there outdoor options available?
A: Yes, you can opt for the TROVE OUTDOOR enclosure which is rated for outdoor use.
Easily combine Altronix power and accessories with access controllers from the industry’s leading manufacturers – Reducing installation and labor costs!
- Trove streamlines access control design and deployment, increasing profits and ROI.
- Removable backplanes allow you to configure and test prior to on-site installation.
- Trove enclosures are available in different sizes and configurations to meet your project scope –including wall mount, rack mount and outdoor models.
- Pre-configured kits are available with power distribution, finger duct and wire assemblies.
- Combine both access and intrusion modules for various brands – all in one enclosure, for added value!
- Optional LINQ™ Networked Power Management Technology allows you remotely monitor, control and report power/diagnostics, streamlining service and maintenance operations by leveraging the network.
- Altronix products are TAA & NDAA compliant
- Our free online Trove System Design tool simplifies the design and product selection process: www.altronix.com/system_design_tools/trove
Enclosure Options
- TROVE 1
- Knockouts accommodate up to 1.5” conduit
- Accommodates two (2) 12VDC/7AH batteries Dimensions: 18” H x 14.5” W x 4.625” D
- TROVE2
- Knockouts accommodate up to 2.0” conduit
- Accommodates four (4) 12VDC/12AH batteries Dimensions: 27.25” H x 21.75” W x 6.5” D
- TROVE3
- Knockouts accommodate up to 2.0” conduit
- Accommodates four (4) 12VDC/12AH batteries Dimensions: 36.12” H x 30.12” W x 7.06” D
TROVE OUTDOOR
- NEMA 4/4X, IP66-11Rated Outoor Enclosure
- Lockable latches and integral flanges simplify mounting
- Dimensions: 17.53” H x 15.3” W x 6.67” D
TROVE RACK MOUNT
- 2U, 24” or 36” deep rack drawer on extendable rails
- Integrated Z bracket on rear facilitates wiring Dimensions: 3.375” H x 19” W x 24” D
Access and Power Integration
Altronix®
Access and Power Integration |
OnGuard Platform |
|||
Altronix Model | Description | System Capacity | Compatible LenelS2 OnGuard Models | |
Trove1 Series – Accommodates Altronix Power and Distribution with Controllers | ||||
TROVE1M1 | Enclosure + Backplane | 8-Doors |
LNL-2220, LNL-4420, LNL-1100, LNL-1200, LNL-3300, LNL-8000, LNL-2210, LNL-1300, LNL-1300e |
|
TM1 | Backplane only | |||
Trove2 Series – Accommodates Altronix Power and Distribution with Controllers | ||||
TROVE2M2 | Enclosure + Backplane | 12-Doors | ||
TM2 | Backplane only | |||
Trove3 Series – Accommodates Altronix Power and Distribution with Controllers | ||||
TROVE3M3 | Enclosure + Backplane | 24-Doors | ||
TM3 | Backplane only | |||
Trove2 and Trove3 Door Backplane only | ||||
TMV2 |
Door Backplane only |
12-Doors |
LNL-2220, LNL-4420, LNL-1100, LNL-1200, LNL-3300, LNL-8000, LNL-2210, LNL-1300, LNL-1300e |
|
Compact Mercury Enclosures | ||||
TM250 | Enclosure | 2-Doors | LNL-2210, LNL-1300, LNL-1300e | |
TM400 |
Enclosure |
2-Doors |
LNL-2220, LNL-4420, LNL-1100, LNL-1200, LNL-3300, LNL-8000, LNL-2210, LNL-1300, LNL-1300e |
Altronix®
Access and Power Integration |
OnGuard Platform |
|||||
Altronix Model | Description | System Capacity | Compatible LenelS2 OnGuard Models | |||
Trove1 Pre-configured Kits |
LNL-2220, LNL-4420, LNL-1100, LNL-1200, LNL-3300, LNL-8000, LNL-2210, LNL-1300, LNL-1300e |
|||||
Fuse Protected Models | PTC Protected Models | |||||
T1MK1F4 | eFlow4NB, ACM4, VR6 | T1MK1F4D | eFlow4NB, ACM4CB, VR6 | 4-Doors | ||
T1MK1F4S | eFlow4NB, ACM4, VR6, PDS8 | T1MK1F4SD | eFlow4NB, ACM4CB, VR6, PDS8CB | |||
Managed Fuse Protected Models | Managed PTC Protected Models | |||||
T1MK1F4Q | eFlow4NB, LINQ2, ACM4, VR6, PDS8 | T1MK1F4DQ | eFlow4NB, LINQ2, ACM4CB, VR6 | 4-Doors | ||
T1MK1F4SQ | eFlow4NB, LINQ2, ACM8, VR6, PDS8 | T1MK1F4SDQ | eFlow4NB, LINQ2, ACM4CB, VR6, PDS8CB | |||
220VAC units available upon request, add suffix “V” (T1MK1F4V) |
Altronix®
Access and Power Integration |
OnGuard Platform |
|||||
Altronix Model | Description | Altronix Model | Description | System Capacity | Compatible LenelS2 OnGuard Models | |
Trove2 Pre-configured Kits |
LNL-2220, LNL-4420, LNL-1100, LNL-1200, LNL-3300, LNL-8000, LNL-2210, LNL-1300, LNL-1300e |
|||||
Fuse Protected Models | PTC Protected Models | |||||
T2MK3F4 | eFlow6NB, ACM4, VR6, PDS8 | T2MK3F4D | eFlow6NB, ACM4CB, VR6, PDS8CB | 4-Doors | ||
T2MK3F8 | eFlow6NB, ACM8, VR6, PDS8 | T2MK3F8D | eFlow6NB, ACM8CB, VR6, PDS8CB | 8-Doors | ||
T2MK7F8 | eFlow104NB, ACM8, VR6, PDS8 | T2MK7F8D | eFlow104NB, ACM8CB, VR6, PDS8CB | |||
Managed Fuse Protected Models | Managed PTC Protected Models | |||||
T2MK3F4Q | eFlow6NB, LINQ2, ACM4, VR6, PDS8 | T2MK3F4DQ | eFlow6NB, LINQ2, ACM4CB, VR6, PDS8CB | 4-Doors | ||
T2MK3F8Q | eFlow6NB, LINQ2, ACM8, VR6, PDS8 | T2MK3F8DQ | eFlow6NB, LINQ2, ACM8CB, VR6, PDS8CB | 8-Doors | ||
T2MK7F8Q | eFlow104NB, LINQ2,ACM8, VR6, PDS8 | T2MK7F8DQ | eFlow104NB, LINQ2, ACM8CB, VR6, PDS8CB | |||
Trove2 Series Pre-configured Kits (Utilizing TMV2 Door Backplane) | ||||||
Fuse Protected Models | PTC Protected Models | |||||
T2MK75F16 | eFlow102NB, eFlow104NB, 2-ACM8, PD16W | T2MK75F16D | eFlow102NB, eFlow104NB, 2-ACM8CB, PD16WCB |
16-Doors |
||
T2MK77F16 | 2-eFlow104NB, 2-ACM8, VR6, PDS8 | T2MK77F16D | 2-eFlow104NB, 2-ACM8CB, VR6, PDS8CB | |||
Managed Fuse Protected Models | Managed PTC Protected Models | |||||
T2MK75F16Q |
eFlow102NB, eFlow104NB, LINQ2, 2-ACM8, PD16W |
T2MK75F16DQ |
eFlow102NB, eFlow104NB, LINQ2, 2-ACM8CB, PD16WCB |
16-Doors |
||
T2MK77F16Q | 2-eFlow104NB, LINQ2 ,2-ACM8, VR6, PDS8 | T2MK77F16DQ | 2-eFlow104NB, LINQ2, 2-ACM8CB, VR6, PDS8CB | |||
220VAC units available upon request, add suffix “V” (T2MK3F4DV) |
Altronix®
Access and Power Integration |
OnGuard Platform |
||||
Altronix Model | Description | Altronix Model | Description | System Capacity | Compatible LenelS2 OnGuard Models |
Trove3 Series Pre-configured Kits |
LNL-2220, LNL-4420, LNL-1100, LNL-1200, LNL-3300, LNL-8000, LNL-2210, LNL-1300, LNL-1300e |
||||
Fuse Protected Models | PTC Protected Models | ||||
T3MK75F16 |
eFlow102NB, eFlow104NB, 2-ACM8, PD8UL, RSB2 |
T3MK75F16D |
eFlow102NB, eFlow104NB, 2-AC- M8CB, PD8ULCB, RSB2 |
16-Doors |
|
T3MK77F16 |
2-eFlow104NB, 2-ACM8,
2-PD8UL, RSB2 |
T3MK77F16D |
2-eFlow104NB, 2-ACM8CB,
2-PD8ULCB, RSB2 |
||
T3MK75F16S |
eFlow102NB, eFlow104NB, 2-ACMS8, PDS8, RSB2 |
T3MK75F16SD |
eFlow102NB, eFlow104NB, 2-ACMS8CB, PDS8CB, RSB2 | ||
T3MK77F16S |
2-eFlow104NB, 2-ACMS8,
2-PDS8, 2-VR6, RSB2 |
T3MK77F16SD |
2-eFlow104NB, 2-ACMS8CB,
2-PDS8CB, 2-VR6, RSB2 |
||
220VAC units available upon request, add suffix “V” (T3MK75F16V) |
Pre-wired Access and Power Integration Kits
Altronix
Pre-wired Access and Power Integration Kits |
OnGuard Platform |
||||||
Altronix Model | Description | Altronix Model | Description | System Capacity | Compatible LenelS2 OnGuard Models | ||
Trove2 Series – Includes Power Distribution, Wire Assemblies for Controllers and Finger-duct for Wire Management | |||||||
Fuse Protected Models | PTC Protected Models | ||||||
T2M7XK1 | Trove2M2 with eFlow104NB, ACMS8, VR6, PDS8, RSB1 | T2M7XK1D | Trove2M2 with eFlow104NB, ACMS8CB, VR6,
PDS8CB, RSB1 |
8-Doors | 1-LNL-2220 and 3-LNL-1320 | ||
T2M7XK2 | T2M7XK2D | 6-Doors | 1-LNL-3300 and 3-LNL-1320 | ||||
T2M7XK3 | T2M7XK3D | 8-Doors | 4-LNL-1320 | ||||
Managed Trove2 Series – Includes Power Distribution, Wire Assemblies for Controllers and Finger-duct for Wire Management | |||||||
Fuse Protected Models | PTC Protected Models | ||||||
T2M7XK1Q | Trove2M2 with eFlow104NB, LINQ8ACM, VR6,
LINQ8PD, RSB1 |
T2M7XK1DQ | Trove2M2 with eFlow104NB, LINQ8ACMCB, VR6,
LINQ8PDCB, RSB1 |
8-Doors | 1-LNL-2220 and 3-LNL-1320 | ||
T2M7XK2Q | T2M7XK2DQ | 6-Doors | 1-LNL-3300 and 3-LNL-1320 | ||||
T2M7XK3Q | T2M7XK3DQ | 8-Doors | 4-LNL-1320 | ||||
220VAC units available upon request, add suffix “V” (T2M7XK1V) |
Altronix
Pre-wired Access and Power Integration Kits |
OnGuard Platform |
||||||
Altronix Model | Description | Altronix Model | Description | System Capacity | Compatible LenelS2 OnGuard Models | ||
Trove3 Series – Includes Power Distribution, Wire Assemblies for Controllers and Finger-duct for Wire Management | |||||||
Fuse Protected Models | PTC Protected Models | ||||||
T3M77XK1 | Trove3M3 with 2-eFlow104NB, 2-ACMS8, 2-VR6,
2-PDS8, RSB2 |
T3M77XK1D | Trove3M3 with 2-eFlow104NB, 2-ACMS8CB, 2-VR6,
2-PDSCB, RSB2 |
16-Doors | 1-LNL-2220 and 7-LNL-1320 | ||
T3M77XK2 | T3M77XK2D | 14-Doors | 1-LNL-3300 and 7-LNL-1320 | ||||
T3M77XK3 | T3M77XK3D | 16-Doors | 8-LNL-1320 | ||||
T3M7724XK1 | Trove3M3 with TMV2
2-eFlow104NB, 2-ACMS12, 2-PDS8, RSB2 |
T3M7724XK1D | Trove3M3 with TMV2
2-eFlow104NB, 2-ACMS12CB, 2-PDS8CB, RSB2 |
24-Doors | 1-LNL-2220 and 11-LNL-1320 | ||
T3M7724XK2 | T3M7724XK2D | 22-Doors | 1-LNL-3300 and 11-LNL-1320 | ||||
T3M7724XK3 | T3M7724XK3D | 24-Doors | 12-LNL-1320 | ||||
Managed Trove3 Series – Includes Power Distribution, Wire Assemblies for Controllers and Finger-duct for Wire Management | |||||||
Fuse Protected Models | PTC Protected Models | ||||||
T3M77XK1Q | Trove3M3 with 2-eFlow104NB, 2-LINQ8ACM, 2-VR6,
2-LINQ8PD, RSB2 |
T3M77XK1DQ | Trove3M3 with 2-eFlow104NB, 2-LINQ8ACMCB, 2-VR6,
2-LINQ8PDCB, RSB2 |
16-Doors | 1-LNL-2220 and 7-LNL-1320 | ||
T3M77XK2Q | T3M77XK2DQ | 14-Doors | 1-LNL-3300 and 7-LNL-1320 | ||||
T3M77XK3Q | T3M77XK3DQ | 16-Doors | 8-LNL-1320 | ||||
220VAC units available upon request, add suffix “V” (T2M7XK1V) |
Altronix
Pre-wired Access and Power Integration Kits |
OnGuard Platform |
||||||
Altronix Model | Description | Altronix Model | Description | System Capacity | Compatible MERCURY* Models | ||
Trove1 Series – Includes Power Distribution, Wire Assemblies for Controllers and Wire Magnets for Wire Management | |||||||
Fuse Protected Models | PTC Protected Models | ||||||
T1M1CK1 | Trove1M1 with eFlow4NB,ACM4, VR6, PDS8, RSB1 | T1M1CK1D | Trove1M1 with eFlow4NB, ACM4CB, VR6, PDS8CB, RSB1 | 4-Doors | 1-LNL-2220 and 1-LNL-1320 | ||
T1M1CK2 | T1M1CK2D | 2-Doors | 1-LNL-3300 and 1-LNL-1320 | ||||
T1M1CK3 | T1M1CK3D | 4-Doors | 2-LNL-1320 | ||||
Managed Trove1 Series – Includes Power Distribution, Wire Assemblies for Controllers and Wire Magnets for Wire Management | |||||||
Fuse Protected Models | PTC Protected Models | ||||||
T1M1CK1Q | Trove1M1 with eFlow4NB, VR6, LINQ8PD, RSB1 | T1M1CK1DQ | Trove1M1 with eFlow4NB, VR6, LINQ8PDCB, RSB1 | 4-Doors | 1-LNL-2220 and 1-LNL-1320 | ||
T1M1CK2Q | T1M1CK2DQ | 2-Doors | 1-LNL-3300 and 1-LNL-1320 | ||||
T1M1CK3Q | T1M1CK3DQ | 4-Doors | 2-LNL-1320 | ||||
220VAC units available upon request, add suffix “V” (T1M7XK1V) |
Altronix
Pre-wired Access and Power Integration Kits |
OnGuard Platform |
||||||
Altronix Model | Description | Altronix Model | Description | System Capacity | Compatible MERCURY* Models | ||
Trove2 Series – Includes Power Distribution, Wire Assemblies for Controllers and Wire Magnets for Wire Management | |||||||
Fuse Protected Models | PTC Protected Models | ||||||
T2M7CK1 | Trove2M2 with eFlow104NB, ACMS8, VR6, PDS8, RSB1 | T2M7CK1D | Trove2M2 with eFlow104NB, ACMS8CB, VR6, PDS8CB, RSB1 | 8-Doors | 1-LNL-2220 and 3-LNL-1320 | ||
T2M7CK2 | T2M7CK2D | 6-Doors | 1-LNL-3300 and 3-LNL-1320 | ||||
T2M7CK3 | T2M7CK3D | 8-Doors | 4-LNL-1320 | ||||
Trove3 Series – Includes Power Distribution, Wire Assemblies for Controllers and Wire Magnets for Management | |||||||
Fuse Protected Models | PTC Protected Models | ||||||
T3M77CK1 | Trove3M3 with 2-eFlow104NB, 2-ACMS8, 2-VR6, 2-PDS8, RSB2 | T3M77CK1D | Trove3M3 with 2-eFlow104NB,
2-ACMS8CB, 2-VR6, 2-PDSCB, RSB2 |
16-Doors | 1-LNL-2220 and 7-LNL-1320 | ||
T3M77CK2 | T3M77CK2D | 14-Doors | 1-EP(LP)2500 and 7-LNL-1320 | ||||
T3M77CK3 | T3M77CK3D | 16-Doors | 8-LNL-1320 | ||||
220VAC units available upon request, add suffix “V” (T2M7CK1V) |
Altronix
Pre-wired Access and Power Integration Kits |
OnGuard Platform |
||||||
Altronix Model | Description | Altronix Model | Description | System Capacity | Compatible MERCURY* Models | ||
Managed Trove2 Series – Includes Power Distribution, Wire Assemblies for Controllers and Wire Magnets for Wire Management | |||||||
Fuse Protected Models | PTC Protected Models | ||||||
T2M7CK1Q | Trove2M2 with eFlow104NB, LINQ8ACM, VR6, LINQ8PD, RSB1 | T2M7CK1DQ | Trove2M2 with eFlow104NB, LINQ8ACMCB, VR6, LINQ8PDCB, RSB1 | 8-Doors | 1-LNL-2220 and 3-LNL-1320 | ||
T2M7CK2Q | T2M7CK2DQ | 6-Doors | 1-LNL-3300 and 3-LNL-1320 | ||||
T2M7CK3Q | T2M7CK3DQ | 8-Doors | 4-LNL-1320 | ||||
Managed Trove3 Series – Includes Power Distribution, Wire Assemblies for Controllers and Wire Magnets for Management | |||||||
Fuse Protected Models | PTC Protected Models | ||||||
T3M77CK1Q | Trove3M3 with 2-eFlow104NB, 2-LINQ8ACM, 2-VR6, 2-LINQ8PD,
RSB2 |
T3M77CK1DQ | Trove3M3 with 2-eFlow104NB,
2-LINQ8ACMCB, 2-VR6, 2-LINQ8PDCB, RSB2 |
16-Doors | 1-LNL-2220 and 7-LNL-1320 | ||
T3M77CK2Q | T3M77CK2DQ | 14-Doors | 1-EP(LP)2500 and 7-LNL-1320 | ||||
T3M77CK3Q | T3M77CK3DQ | 16-Doors | 8-LNL-1320 | ||||
220VAC units available upon request, add suffix “V” (T2M7CK1V) |
Rack Mount Access and Power Integration
Altronix®
Rack Mount Access and Power Integration |
OnGuard Platform |
|||||
Altronix Model |
Description |
System Capacity |
Compatible Mercury* Models |
|||
Mercury Trove1R 24” Rack Series – Accommodates Altronix Power and Distribution with Controllers | LNL-2220, LNL-4420, LNL-1100, LNL-1200, LNL-3300,
LNL-8000, LNL-2210, LNL-1300, LNL-1300e |
|||||
TROVE1M1R | 2U Rack 19” Depth Enclosure + Backplane | 4-Doors | ||||
Mercury Trove2R 40” Rack Series – Accommodates Altronix Power and Distribution with Controllers | ||||||
TROVE2M2R | 2U Rack 19” Depth Enclosure + Backplane | 8-Doors | ||||
Altronix Model |
Description |
Altronix Model |
Description |
System Capacity |
Compatible Mercury* Models |
|
Trove 24” Rack Series Pre-assembled Kits |
LNL-2220, LNL-4420, LNL-1100, LNL-1200, LNL-3300, LNL-8000, LNL-2210, LNL-1300, LNL-1300e |
|||||
Fuse Protected Models | PTC Protected Models | |||||
T1RM3F4 | eFlow6NB, ACM4, VR6, PDS8 | T1RM3F4D | eFlow6NB, ACM4CB, VR6, PDS8CB | 4-Doors | ||
Trove 40” Rack Series Pre-assembled Kits | ||||||
Fuse Protected Models | PTC Protected Models |
8-Doors |
||||
T2RM7F8S | eFlow104NB, ACMS8, VR6, PDS8 | T2RM7F8SD | eFlow104NB, ACMS8CB, VR6, PDS8CB | |||
Managed Fuse Protected Models | Managed PTC Protected Models | |||||
T2RM7F8SQ | eFlow104NB, LINQ8ACM, VR6, PDS8 | T2RM7F8SDQ | eFlow104NB, LINQ8ACMCB, VR6, PDS8CB | |||
220VAC units available upon request, add suffix “V” (T1RM3F4V) |
Altronix
Pre-wired Rack Access and Power Integration Kits |
OnGuard Platform |
|||||
Altronix Model | Description | Altronix Model | Description | System Capacity | Compatible Mercury* Models | |
Trove1R 24” Series – Includes Power Distribution, Wire Assemblies for Controllers and Wire Magnets for Management | ||||||
Fuse Protected Models | PTC Protected Models |
4-Doors |
1-LNL-2220 and 1-LNL-1320 | |||
T1RM3CK1 | Trove1M1R with eFlow6NB, ACM4, VR6, PDS8 | T1RM3CK1D | Trove1M1R with eFlow6NB, ACM4CB, VR6, PDS8CB | |||
T1RM7CK1 | Trove1M1R with eFlow104NB, ACM4, VR6, PDS8 | T1RM7CK1D | Trove1M1R with eFlow104NB, ACM4CB, VR6, PDS8CB | |||
Trove2R 40” Series – Includes Power Distribution, Wire Assemblies for Controllers and Wire Magnets for Management | ||||||
Fuse Protected Models | PTC Protected Models |
8-Doors |
1-LNL-2220 and 3-LNL-1320 |
|||
T2M7CK1 | Trove2M2R with eFlow104NB, ACMS8, VR6, PDS8 | T2M7CK1D | Trove2M2R with eFlow104NB, ACMS8CB, VR6, PDS8CB | |||
Managed Fuse Protected Models | Managed PTC Protected Models | |||||
T2M7CK1Q | Trove2M2R with eFlow104NB, LINQ8ACM, VR6, PDS8 | T2M7CK1DQ | Trove2M2R with eFlow104NB, LINQ8ACMCB, VR6, PDS8CB | |||
220VAC units available upon request, add suffix “V” (T1RM3CK1V) |
Power Supply/Chargers for TROVE Series |
|
||||||
Altronix Model |
Total Output Power |
Number of Outputs | Built-in Battery Charger |
Input |
Dimensions (L x W x H) | ||
ULXB Series Power Supply/Chargers | |||||||
AL400ULXB2 | 12VDC @ 4A or 24VDC @ 3A |
1 |
SLA |
115VAC |
7.1” x 4.5” x 1.44” | ||
AL600ULXB | 12VDC or 24VDC @ 6A | 7.1” x 4.5” x 2.6” | |||||
AL1012ULXB | 12VDC @ 10A | 7.5” x 4.5” x 2.25” | |||||
AL1024ULXB2 | 24VDC @ 10A | 8.4” x 4.5” x 1.95” | |||||
AL400ULXB2V | 12VDC @ 4A or 24VDC @ 3A |
220VAC |
7.1” x 4.5” x 1.44” | ||||
AL600ULXB220 | 12VDC or 24VDC @ 6A | 7.1” x 4.5” x 2.6” | |||||
AL1012ULXB220 | 12VDC @ 10A | 7.5” x 4.5” x 2.25” | |||||
AL1024ULXB2V | 24VDC @ 10A | 8.4” x 4.5” x 1.95” | |||||
eFlow Series Power Supply/Chargers | |||||||
eFlow4NB | 12VDC or 24VDC @ 4A |
1 Main Output, 1Aux. Output (1A) |
SLA |
115VAC |
7.5” x 4.6” x 1.75” | ||
eFlow6NB | 12VDC or 24VDC @ 6A | 7.5” x 4.6” x 1.75” | |||||
eFlow102NB | 12VDC @ 10A | 7.5” x 4.6” x 1.75” | |||||
eFlow104NB | 24VDC @ 10A | 8.25” x 4.56” x 1.75” | |||||
eFlow4NBV | 12VDC or 24VDC @ 4A |
220VC |
7.5” x 4.6” x 1.75” | ||||
eFlow6NBV | 12VDC or 24VDC @ 6A | 7.5” x 4.6” x 1.75” | |||||
eFlow102NBV | 12VDC @ 10A | 7.5” x 4.6” x 1.75” | |||||
eFlow104NBV | 24VDC @ 10A | 8.25” x 4.56” x 1.75” | |||||
Tango PoE Driven Power Supply/Charger | |||||||
Tango1B | 12VDC up to 6.25A (75W) and 24VDC up to 3A (75W) | 2 | LiFePO4 | 90W 802.3bt PoE | 7.625” x 4.125” x 1.25” |
PoE Power Sourcing Equipment | |
Altronix Model | Description |
NetWay1BT | Single Port 802.3bt Converter/Injector – 115/230VAC Input, 90W Output |
NetWay8BT | 8-Port Managed 802.3bt Midspan Injector supplies 90W per port (480W total power) |
Power Distribution / Sub Assemblies for TROVE Series |
|||||
Altronix Model |
Description |
Number of Outputs |
Dimensions |
||
ACM4 / ACM4CB | 4-Output Access Power Controller | 4 | 5.175” x 3.36” x 1.25” | ||
ACM8 / ACM8CB | 8-Output Access Power Controller | 8 | 8” x 4.5” 1.25” | ||
ACMS8 / ACMS8CB | Dual Input, 8-Output Access Power Controller | 8 | 8” x 4.5” 1.25” | ||
ACMS8K1 / ACMS8CBK1 | Dual Input, 8-Output Access Power Controller and Voltage Regulator Kit | 8 | 8” x 4.5” 2.125” | ||
ACMS12 / ACMS12CB | Dual Input, 12-Output Access Power Controller | 12 | 8” x 4.5” 1.25” | ||
LINQ8PD / LINQ8PDCB | Dual Input, 8-Output Network Power Distribution Module
– Control, Monitor and report Power/Diagnostics |
8 |
5.5” x 3.625” x 1.25” |
||
LINQ8ACM / LINQ8ACMCB | Dual Input, 8-Output Network Power Access Power Controller
– Control, Monitor and report Power/Diagnostics |
8 |
8”x 4.5”x 1.25” |
||
LPD | Low Power Disconnect Module (12/24VDC input) | N/A | 2” x 2.75” 1” | ||
M0M5 | 5-Output Power Distribution Module with Fire Alarm Interface | 5 | 5.25” x 3.5” x 1” | ||
NETWAY5A | 5-Port Switch Board Facilitates Network Drops (10/100) | 5 | 5.625” x 3.5” x 1” | ||
NETWAY5B | 5-Port Switch Board Facilitates Network Drops (10/100/1000) | 5 | 5.625” x 3.5” x 1” | ||
NETWAY5P | 5-Port Hardened PoE+ Switch Board | 5 | 5.6” x 3.6” x 0.75” | ||
NETWAY5PQ | 5-Port Hardened Managed PoE+ Switch Board | 5 | 5.6” x 3.6” x 0.75” | ||
PD4UL / PD4ULCB | 4-Output Power Distribution Module | 4 | 5.21” x 3.25” x 1” | ||
PD8UL / PD8ULCB | 8-Output Power Distribution Module | 8 | 5.21” x 3.25” x 1” | ||
PDS8 / PDS8CB | Dual Input, 8-Output Power Distribution Module | 8 | 5.375” x 3” x 1” | ||
PDS8K1 / PDS8CBK1 | Dual Input, 8-Output Power Distribution Module and Voltage Regulator Kit | 8 | 5.375” x 3” x 2” | ||
PD16W / PD16WCB | 16-Output Power Distribution Module | 16 | 5.875” x 6” x 0.95” | ||
PDS16 / PDS16CB | Dual Input, 16-Output Power Distribution Module | 16 | 5.375” x 3” x 1” | ||
VR6 | Stackable Voltage Regulator Converts a 24VDC input to 5VDC or 12VDC at 6A | 1 | 5.375” x 3” x 1” | ||
VR10 | Stackable Voltage Regulator Converts a 24VDC input to 5VDC or 12VDC at 10A | 1 | 5.375” x 3” x 1” |
Optional Accessories for TROVE Series
Optional Accessories for TROVE Series |
|||
Altronix Model | Description | ||
BL3 | 18” Battery Leads (black and red) | ![]()
|
|
BL4 | 8” Battery Series Jumper (yellow) | ||
BL6 | 68” Battery Leads (black and red) | ||
BR1 | Add-on mounting bracket. Mount additional Altronix sub-assemblies to the enclosure’s side wall. | ||
BT126 | 12VDC / 7AH Rechargeable Battery | ||
BT1212 | 12VDC / 12AH Rechargeable Battery | ||
BTL125 | Rechargeable 12V Lithium Iron Phosphate (LiFePO4) Battery | ||
CLK1 | Thumb Lock. Fits Trove1, Trove2 and Trove3 enclosures. | ||
DNP1 |
Altronix DIN Rail Adapter Plate accommodates the following sub-assemblies: ACM4(CB, ACM8(CB), ACM8(CB), ACMS8(CB), ACMS12(CB), LINQ8PD(CB), LINQ8ACM(CB), MOM5, NETWAY5A, NETWAY5B, NETWAY5P, NETWAY5PQ, PD4UL(CB), PD8UL(CB), PDS8(CB), PDS16(CB) | ||
GB1 | Altronix Adapter Plate for Genetec Synergis Cloud Link (For Mercury and HID/Vertx) | ||
MM4 | Mounting Magnets. 26 lbs. holding force. Pack of 4. | ||
MM8 | Mounting Magnets. 26 lbs. holding force. Pack of 8. | ||
MM12 | Mounting Magnets. 26 lbs. holding force. Pack of 12. | ||
MM24 | Mounting Magnets. 26 lbs. holding force. Pack of 24. | ||
PSC1 | Power Supply Protective Cover (Includes standoffs) | ||
RSB1 | Rocker Switch with Bracket – Includes single Master Power ON/OFF Switches and Wires | ||
RSB2 | Rocker Switches with Bracket – Includes two (2) Master Power ON/OFF Switches and Wires | ||
SPACER1 | 5/8” Nylon female/female spacers (standoffs) with 6/32 screws. Pack of 25. | ||
SPACER3 | 5/8” Aluminum female/female spacers (standoffs) with 6/32 screws. Pack of 25. | ||
SPACER4 | 5/8” Nylon male/female spacers (standoffs) with 6/32 screws. Pack of 25. | ||
SPACER5 | 5/8” Nylon snap-on spacers (standoffs) with 6/32 screws. Pack of 32. | ||
SPACER6 | 1” Aluminum female/female spacers (standoffs) with 6/32 screws. Pack of 4. | ||
SPACER7 | 5/8” Aluminum male/female spacers (standoffs) with 6/32 screws. Pack of 25. | ||
SPACER8 | 1” Nylon female/female spacers (standoffs) with 6/32 screws. Pack of 4. | ||
SPACER9 | 5/8” Aluminum spacers (standoffs) with 4/40 screws. Pack of 8. | ||
TROVE2BWC | Wire trough/Battery enclosure compliments Trove2 enclosures
to accommodate up to four (4) 12VDC/18AH batteries, or conceal side wiring (horizontal mount) |
||
TROVE3BWC | Wire trough/Battery enclosure compliments Trove3 enclosures
to accommodate up to four (4) 12VDC/18AH batteries, or conceal wiring (horizontal mount) |
||
TROVE3SWC | Wire trough/Battery enclosure compliments Trove3 enclosures
to accommodate up to four (4) 12VDC/40AH batteries, or conceal side wiring (vertical mount) |
||
WM5 | Magnetic cable tie mount. Accommodates standard zip ties. 16 lbs. holding force. Pack of 5. | ||
WM10 | Magnetic cable tie mount. Accommodates standard zip ties. 16 lbs. holding force. Pack of 10. | ||
WM25 | Magnetic cable tie mount. Accommodates standard zip ties. 16 lbs. holding force. Pack of 25. | ||
WM100 | Magnetic cable tie mount. Accommodates standard zip ties. 16 lbs. holding force. Pack of 100. |
Documents / Resources
![]() |
Altronix T2MK3F4Q Lore Plus Technology [pdf] Owner's Manual T2MK3F4Q, T2MK3F4DQ, TROVE1M1, TROVE2M2, TROVE3M3, TMV2, TM250, TM400, T2MK3F4Q Lore Plus Technology, T2MK3F4Q, Lore Plus Technology, Plus Technology, Technology |