ALLEGION-LOGO

ALLEGION 8644 Zero Threshold Section

ALLEGION-8644-Zero-Threshold-Section-PRODUCT

Product Specifications

  • Intended Use: Threshold for fire doors
  • Material: Aluminum
  • Fire Rating: Up to 3 hours for steel frames, up to 1.5 hours  for wood and plastic-covered composite doors, up to 20 minutes for wood core doors
  • Standards Met: UL10B, UL10C, CAN4-S104-2010 Category J .17L5 9903

Product Usage Instructions

Customer Service:

Caution: Edges of aluminum parts may be sharp. Wear gloves and handle with care.

  1. Measure and Cut: Measure the door sill at the bottom of the frame. Cut the threshold to span the full width of the opening.
  2. Notch for Jamb Stops: If the door frame has side jamb stops, notch the threshold ends as needed to ensure a proper fit.
  3. Secure the Threshold: Place the threshold on the sill and fasten it in place using the provided screws.
  4. Check Door Operation: Open and close the door several times to confirm that it latches and closes smoothly. Make any necessary adjustments to the threshold.

ALLEGION-8644-Zero-Threshold-Section-FIG-1 Positive Pressure Tested Gasketing Materials for Fire Doors. Intended for Application to/ with listed steel frames and/or classified steel covered composite, hollow metal-type fire doors rated up to 3 hours, wood and plastic-covered composite-type fire doors rated up to 1- 1/2 hours, and wood core-type fire doors rated up to 20 minutes. Meets UL10B, UL10C and CAN4-S104-2010

  • Category J .17L5 9903
  • © Allegion 2025
  • Printed in U.S.A.
  • 016359 Rev. 07/25

FAQs

Q: Are gloves necessary when handling the aluminum parts?

A: Yes, it is recommended to wear gloves as the edges of aluminum parts may be sharp.

Q: What type of fire doors is this threshold suitable for?

A: This threshold is suitable for use with steel frames, wood and plastic covered composite doors, and wood core doors with specific fire ratings as mentioned in the specifications.

Q: What standards does this product meet?

A: This product meets UL10B, UL10C, and CAN4-S104-2010 Category J 17L5 9903 standards.

Documents / Resources

ALLEGION 8644 Zero Threshold Section [pdf] Installation Guide
8644 Zero Threshold Section, 8644, Zero Threshold Section, Threshold Section, Section

References

Leave a comment