ALIENTEK DM40A Touchable Multimeter
Specifications
- Product Name: DM40 Touchable Multimeter 3-IN-1
- Manufacturer: Guangzhou Xingyi Electronic Technology Co., Ltd.
- Features: 3-IN-1 Multimeter with Oscilloscope & Signal Generator
- Power Source: Rechargeable Battery
- Safety Features: Shockproof, Slide to Shutdown, Mode Memory
- Connectivity: Bluetooth for App Integration
Revision History
Version | Date | Modify Contents |
V1.0 | 2024/12/07 | First release |
V1.1 | 2024/12/11 | Added firmware upgrade, custom boot logo, quick screenshot instructions |
V1.2 | 2024/12/13 | Added multimeter measurement settings instructions, added AUTO+ mode |
V1.3 | 2024/12/25 | Added data record, resistor mode settings, shockproof mode, slide to shutdown |
V1.4 | 2025/01/18 | Added mode memory, quick mode switch of resistor, countdown shutdown |
V1.5 | 2025/03/24 | Add Bluetooth function description and add custom boot logo explanation |
Thank you for purchasing this product. To fully understand its features and operation, we recommend reading this manual carefully before use.
Safety Instructions (Must Read)
- Before using DM40, please check carefully if the shell has cracks or defects, and ensure the measurement ports and accessories are normal.
- DM40 integrates a rechargeable battery. For safety and measurement stability, please do not
measure while charging. Low battery reminders may affect accuracy. Please charge promptly. - Please select the correct measurement port, range, and scale to avoid damaging the instrument or causing personal injury!
- Hold the probe at the protected position. Do not hold the metal part for measurement!
- Do not disassemble the case at will or measure while the case is open.
- Do not use in environments with flammable or explosive gases/materials or in damp conditions.
- For voltage measurement, when used for DCDC or high voltage above 36V measurement, it is recommended to use AUTO+ mode to skip the mV range (to avoid mismeasurement, sparking, and protection) and start measurement from the V range.
- To use the Bluetooth function, please go to Settings > Other Settings, turn on the Bluetooth, and then connect via the APP(ATK-XTOOL).
Product Introduction
The DM40 digital multimeter is the first high-performance 3-in-1 multimeter launched by Guangzhou Xingyi Electronic Technology Co., Ltd. Its main features are as follows:
- Integrated multimeter, oscilloscope, and signal generator, featuring comprehensive functions and convenient measurement.
- Equipped with a 3.5-inch 480*320 IPS capacitive touchscreen, providing delicate display and convenient interaction.
- 4-5/6 multimeter with a count of up to 60000 (C version), TRMS true RMS measurement, precise and reliable.
- Automatic mV/V range and innovative uA/mA/A range design for quick and efficient measurement.
- AC+DC mixed measurement (B/C versions), no signal escapes detection.
- Super diode measurement with multi-segment beep design, quick response, and support for resistance (<1KΩ) measurement.
- Supports resistance, capacitance, continuity, frequency, temperature, and other measurements.
- Supports manual (V/A/Ω)/automatic range, RLE relative measurement, extreme value measurement, data hold.
- Supports trend chart display for efficient data analysis with 3 adjustable time bases.
- Oscilloscope with 50MSa/s sampling rate, 10MHz bandwidth, and 10-bit vertical resolution.
- Oscilloscope supports multiple trigger modes and types, as well as FFT and ABS operations. 12○ Signal generator supports sine wave, sawtooth wave, triangle wave, and square wave up to 10MHz.
DM40 Basic Parameters
Basic Information | |
Model | DM40A、DM40B、DM40C |
Screen | 3.5′(480*320) IPS Touchscreen |
Battery Life |
≈12H(Multimeter)
≈10H(Oscilloscope) |
Dimensions | 140 * 83 * 25mm |
Weight | ≈260g |
Interface | USB TypeC/MCX Socket/Banana Jack Socket |
Conditions | Temperature 0~40℃、Humidity <75% |
Table 1.0 DM40 Basic information
DM40 Multimeter Technical Parameters:
Multimeter Technical Parameters | |||||
Model | DM40A | DM40B | DM40C | ||
Function | Range | Accuracy | |||
DC Voltage |
400mV/4V/40V
/400V/1000V |
500mV/5V/50V
/500V/1000V |
600mV/6V/60V
/600V/1000V |
±(0.03%+5d) |
|
AC Voltage |
400mV/4V/40V
/400V/750V |
500mV/5V/50V
/500V/750V |
600mV/6V/60V
/600V/750V |
±(0.3%+15d) |
|
DC Current |
400uA/4000uA
/40mA/400mA |
500uA/5000uA
/50mA/500mA |
600uA/6000uA
/60mA/600mA |
±(0.15%+5d) |
|
4A/10A | 5A/10A | 6A/10A | ±(0.2%+5d) | ||
AC Current |
400uA/4000uA
/40mA/400mA |
500uA/5000uA
/50mA/500mA |
600uA/6000uA
/60mA/600mA |
±(0.5%+15d) |
|
4A/10A | 5A/10A | 6A/10A | ±(0.75%+15d) | ||
Resistor |
400Ω/4KΩ/40KΩ
/400KΩ/4MΩ |
500Ω/5KΩ/50KΩ
/500KΩ/5MΩ |
600Ω/6KΩ/60K
Ω/600KΩ/6MΩ |
±(0.1%+5d) |
|
40MΩ | 50MΩ | 60MΩ | ±(0.2%+10d) | ||
Capacitance |
4nF/40nF/400nF
/4uF/40uF |
5nF/50nF/500nF
/5uF/50uF |
6nF/60nF/600nF
/6uF/60uF |
±(2.5%+30d) |
|
400uF/4mF/40mF | 500uF/5mF/50mF | 600uF/6mF/60mF | ±(3.5%+30d) | ||
Frequency | 10Hz~40MHz | 10Hz~50MHz | 10Hz~60MHz | ±(0.01%+5d) | |
Temperature |
-40℃~1000℃(Standard probe range -20℃~300℃)
-40℉~1832℉ |
±(1.0%+5℃)
±(1.5%+5℉) |
|||
Continuity | 0Ω~1KΩ | ±(0.2%+5d) | |||
Diode | 0V~3.0V, 0Ω~1KΩ | ±(1%+5d) | |||
AC Response | 10KHz |
|
Table 1.1 Multimeter Technical Parameters
DM40 Oscilloscope Technical Parameters:
Oscilloscope Technical Parameters | |||
Sample Rate | 50MSa/S | Input lmpedance | 1MΩ |
Bandwidth | 10Mhz | Timebase Mode | YT/ROLL |
Memory Depth | 64Kpts | Sweep Mode | Auto/Normal/Single |
Time Scale | 100ns~50s | Trigger Type | Rising/Falling |
Vertical Scale | 10mV~10V
/div(X1) |
Persistence | OFF /Min/1S/∞ |
Resolution | 10bit | Math | FFT/ABS |
Coupling | AC、DC | Measurement items | 20 types |
Table 1.2 Oscilloscope Technical Parameters
DM40 Signal Generator Technical Parameters:
Signal generator Technical Parameters | |||||
Wave out | Sine Wave | Sawtooth Wave | Triangle Wave | Square Wave | |
Frequency | 1Hz~50KHz | 100KHz~10MHz | |||
Amplitude | 0.5V~3.0Vpp | 3.0Vpp | |||
Duty | Not Adjustable | 0~100% | Not Adjustable |
Table 1.3 Signal Generator Technical Parameters
DM40 Adjustable MCX Probe Parameters:
Adjustable MCX Probe Parameters | ||||
Attenuation
Ratio |
Bandwidth | Input Impedance | Input
Capacitance |
Maximum
Voltage |
X1 | 20MHz | 1MΩ±2% | 50pF±20pF | 40VRMS CATⅡ |
X10 | 140MHz | 10MΩ±2% | 15pF±5pF | 400VRMS CATⅡ |
Table 1.4 Adjustable MCX Probe Parameters
Quick Start
Appearance Description
Description
- Power Button (Long press to turn on/off, double-click to lock/unlock touch)
- TypeC Port (For charging and USB communication, input voltage <5.2V)
- Charging Indicator (Blue light when charging, off when fully charged)
- MCX Signal Generator Port
- MCX Oscilloscope Port
- 3.5″ (480*320) IPS Touchscreen
- Voltage, Resistance, Capacitance, Continuity, Diode, Frequency, Temperature Measurement Ports (Black COM is common)
- Current Measurement Port (Black COM is common)
- Multi-function Touch Buttons (MENU, RUN, AUTO, MF)
Multimeter Measurement Interface
The multimeter interface displays rich content: top status bar; left 4 multi-function touch buttons; middle for various measurement displays; bottom 6 touch buttons to switch 8 measurement functions; as shown in Figure 2.2.1.
Status Bar Description
- Range Indication: AUTO range and manual range (only for voltage, current, resistance).
- Running Status: RUN for running status, HOLD for data hold.
- Uptime: Records uptime (in hours/minutes/seconds).
- Touch Lock/Unlock: Double-click the power button to lock/unlock touch function. After locking, touch is invalid. Single-click the power button can still switch measurement modes within the current mode.
- BT Status: After the APP is successfully connected, the Bluetooth icon appears and disappears when disconnected
- Battery Info: Displays battery level when not charging, charging progress when charging (Do not measure while charging to avoid mismeasurement).
Left Touch Buttons
- MENU: Click to return to the function interface or measurement interface.
- RUN: Click to toggle RUN/HOLD mode. HOLD stops the interface from refreshing (except for Uptime).
- AUTO: Click to restore automatic range and turn off RLE function.
- MF: Enter/exit measurement settings (only for V/A/Ω). For voltage/current, select range first and then AC/DC measurement. For resistance, select range and return to the measurement interface.
Value of measurement
- Aux1: AC mode displays frequency, AC+DC mode displays AC component, temperature mode displays machine temperature.
- Aux2: AC mode and frequency mode display duty, AC+DC mode displays DC component, diode mode displays equivalent resistance, temperature mode displays Fahrenheit.
- Main display: Displays measurement value and units.
- RLE function: In non-OL and data hold states, click RLE button to enable RLE function and enter manual range. Records main display value to RLE. Then main display subtracts the
- RLE value. Click once to update. Click the AUTO button/switch measure mode/long-press the RLE button to turn off this function and restore automatic range.
- MAX/MIN: Records the maximum and minimum measured values. Clears after changing
measurement modes; - Waveform Display: Synchronously displays the main display value. The waveform auto-scales, with horizontal*vertical=20*6 grids. Time base options are 160mS/320mS/640mS.
- Default is 320mS/div;
Mode Setting Buttons
- Voltage Measurement: Cycle through DCV mode, ACV mode, AC+DC mode (only DM40B/C). Current Measurement: Cycle through DCA mode, ACA mode, AC+DC mode (only
- DM40B/C). Resistance Measurement: Click to cycle through offline and online resistance measurement. Online measurement is indicated by Ω with subscript ON.
- Capacitance Measurement: Sets to capacitance measurement mode.
- Diode/Continuity Measurement: Cycle through diode and continuity measurement.
- Frequency/Temperature Measurement: Cycle through frequency and temperature measurement. Note: Switching measurement modes restores AUTO/AUTO+ range and turns off RLE function.
Data Recording
DM40 supports screen data recording. In non-OL state, short-press the main display number area to record and update data once. A short beep indicates recording. The most recently updated data is orange, and others are white. Supports up to 5 sets of data. Older data is overwritten. Long-press the main display area for 1s to clear all records. A long beep indicates clearing.
Measurement Mode Description
Measurement Mode Description | ||
Mode Category | Item Category | Unit+Symbol |
Voltage Measurement | DCV(DC Voltage Measurement) | mV/V |
ACV(AC Voltage Measurement) | mV/V | |
AC+DC Mixed Measurement(DM40B/C) | mV/V | |
Current Measurement | DCA(DC Current Measurement) | uA/mA/A |
ACA(AC Current Measurement) | uA/mA/A | |
AC+DC Mixed Measurement(DM40B/C) | uA/mA/A |
Resistance Measurement | Resistance Measurement(Offline/Online measurement) | Ω/KΩ/MΩ |
CapacitanceMeasurement | Capacitance Measurement | nF/uF/mF |
Diode Measurement | Diode Voltage Drop Measurement | V |
Resistance Measurement | Ω | |
Continuity Measurement | Continuity Measurement | Ω |
Resistance Measurement | ||
Frequency Measurement | Frequency Measurement | Hz/KHz/MHz |
Duty Measurement | % | |
Temperature Measurement | Temperature Measurement | ℃/℉ |
Table 2.3.1 Measurement Mode Description
Measurement Port Description
Measurement Methods
Voltage Measurement
- Click the voltage button(
)to enter voltage measurement mode,Default is DC measurement. Cycle through DCV/ACV/AC+DC measurement by clicking (only DM40B/C).
- Connect the black probe to the black COM port and the red probe to the red VΩHz port.
- Connect the probes to the circuit under test and observe the measured value on the screen. OL indicates out of range.
Note: Do not exceed the maximum measure value. Use auto range if unsure of the voltage range.
Current Measurement
- Click the current button(
)to enter current measurement mode. Default is DC measurement. Cycle through DCA/ACA/AC+DC measurement by clicking (only DM40B/C).
- Connect the black probe to the black COM port and the red probe to the red A mA uA port.
- Connect the probes to the circuit under test and observe the measured value on the screen. OL indicates out of range.
Note: Do not exceed the maximum measure value(10A). Use auto range if unsure of the current range.
Resistance Measurement
- Click the resistance button(Ω)to enter resistance measurement mode.
- Connect the black probe to the black COM port and the red probe to the red VΩHz port.
- Connect the probes to the resistor under test and observe the measured value on the screen. OL indicates out of range.
Note: It is recommended to use online measure mode for online measurement.
Capacitance Measurement
- Click the capacitance button(
)to enter capacitance measurement mode. Capacitance measurement only supports automatic range.
- Connect the black probe to the black COM port and the red probe to the red VΩHz port.
- Discharge the capacitor in advance, then connect the probes to the capacitor under test and observe the measured value on the screen. OL indicates out of range. Testing large mF capacitors takes longer, which is normal.
Note: Do not perform voltage measurement in this mode to avoid damaging the instrument.
Diode/Continuity Measurement
- Click the diode/buzzer button(
)to enter diode measurement mode. Click again to switch to continuity measurement.
- Connect the black probe to the black COM port and the red probe to the red VΩHz port.
- Connect the probes to the component under test. Diode measurement supports 4-segment beeps (<0.02V long beep, <0.45V two short beeps, <0.75V one short beep, <1.5V urgent three short beeps). Maximum voltage drop display is around 3.1V. OL is displayed if exceeded. Also supports resistance measurement within 1KΩ,OL displayed if exceeded. Approximately within 30 Ω, the buzzer beeps continuously。
Note: Do not perform voltage measurement in this mode to avoid damaging the instrument.
Frequency/Temperature Measurement
- Click the frequency/temperature button(Hz°C )to enter frequency measurement mode. Click again to switch to temperature measurement mode.
- For frequency measurement, the recommended input signal amplitude is within 20Vrms, with a limit of 250Vrms. Connect the black probe to the black COM port and the red probe to the red VΩHz port. Connect the probes to the signal under test and observe the measured value on the screen. OL indicates out of range. Aux2 shows signal duty cycle.
- For temperature measurement, connect the thermocouple negative terminal to the black COM port and the positive terminal to the red VΩHz port. Contact the probe with the surface of the object under test and observe the measured value in Celsius, OL indicates out of range. Aux1 shows machine temperature. Aux2 shows measured value of thermocouple in Fahrenheit.
Note: Do not perform voltage measure in temperature mode to avoid damaging the instrument.
Measurement Settings
Voltage and Current Measurement Settings
Taking DM40C voltage measurement setting as an example: Click the voltage V measurement button to enter voltage measurement mode, then Click the MF button to enter the settings interface (similar for current measurement settings).
Explanation:
DM40C include 5 manual ranges (600mV/6V/60V/600V/1000V) and two automatic ranges (AUTO and AUTO+). The difference is that AUTO is a fully automatic range, switching between mV and V ranges automatically, while AUTO+ is a V range automatic range, only switching within V ranges. AUTO+ mode avoids relay flickering and speeds up measurement, suitable for frequent high-voltage or DCDC measurements.
Voltage measurement modes include AC, DC, AC+DC (DM40B/C). Select any one to return to the measurement interface. Clicking MF also returns to the measurement interface. After returning to the main interface, the range mode is indicated in the top-left corner.
The side AUTO button implements AUTO or AUTO+ function according to the settings.
Resistance Measurement Settings
Taking DM40C resistance measurement setting as an example: Click the resistance Ω measurement button to enter resistance measurement mode, then click the MF button to enter the settings interface.
Explanation:
DM40C resistance measurement ranges include 6 manual ranges (600Ω/6KΩ/60KΩ/600K Ω/6MΩ/60MΩ) and one automatic range (AUTO). Select any one or click MF to return to the measurement interface. After returning to the main interface, the range mode is indicated in the top-left corner.
Resistance measurement include offline and online measurements. Offline mode is measuring the resistor separately after removing it, featuring high measurement voltage, fast speed, and high accuracy. Online mode is directly measure on the circuit board, featuring lower voltage, moderate speed, but small deviation. Select one or click MF to return to the measurement interface.
Click the resistance measurement button to quickly cycle through offline and online modes. Online mode is indicated by Ω with subscript ON.
Oscilloscope & Signal Generator Usage Instructions
Please refer to the document: DM40 Oscilloscope & Signal
Generator Manual.pdf
Other Functions
System Settings
Access system settings by clicking Settings on the main interface.
Item | Content | Description |
1.Language | Simplified、Traditional、English | Currently supports 3 languages |
2. Power
manage |
Screen Dim Time :5min、10min、30min、Never | Screen dims to minimum brightness |
Shutdown Time :10min、30min、1h、Never | Auto-shutdown at shutdown time | |
3.Startup page | Multimeter, Oscilloscope,
Signal Generator, Main Interface |
Quickly enter the set startup interface |
4. Volume and
Backlight |
Backlight :10%~100% | Minimum brightness :10% |
Volume :0%~100% | 0% turns off buzzer | |
5. Other Settings |
USB Connection | Firmware update and image upload |
Factory Reset | Restores to default settings | |
Shockproof Mode | Avoid error measurement | |
Mode Remember | DMM measure mode remember | |
Bluetooth | Enable or disable Bluetooth function | |
6.Device info | Manufacturer, Website, Model, Serial Number,
Software and Hardware Version |
Table 4.1 System settings
Firmware Update Instructions
System settings → Other Settings, select USB connection, connect DM40 to a computer via USB cable. The computer will pop up a U-disk. Open the U-disk, place the latest firmware (dm40xxx.bin), eject the U-disk after transfer is complete. Then long-press the power button to restart and update the firmware automatically.
Custom Boot Logo
Create a boot logo with requirements: 480*320 resolution, JPG or BMP format, named logo.jpg or logo.bmp. Connect the device to a computer, open the U-disk, replace the existing logo.bmp file, and restart to apply. To remove the boot logo, delete the file directly.
Quick screenshot instructions
Swipe down with 3 points and hear a beep~ prompt to start taking screenshots. The multimeter interface has anti aliasing effect and saves for a long time (4~5s). After completing the screenshot, it will prompt that the screenshot is successful (the saved image can be copied and viewed by connecting to a computer via USB).
Anti-drop Mode Instructions
mV voltage measurement, resistance measurement, diode and continuity measurement, etc., require magnetic latching relays. Advantages of magnetic latching relays is low power consumption. The disadvantages are high cost, lack of drop resistance, and strong shaking that may cause erroneous measurements, especially for diode and on-off measurements.
Enabling anti-drop mode keeps the relay engaged continuously, effectively avoiding false measurements caused by ordinary collisions. However, it increases power consumption, reducing endurance by about 1 hour. If the device is used in a fixed position without movement, it is recommended to disable shockproof mode for an average endurance of around 12 hours.
Slide to Shutdown and Auto-shutdown Instructions
Slide two fingers down to prompt slide to shutdown. Cancel or slide to the right to shut down. If no touch operations are performed within the auto-shutdown time, a 10s countdown with buzzer prompt will start. No operation will result in auto-shutdown.
Mode Memory Functions
System setting → Others,enable mode memory function will remember the last measurement mode and automatically switch to it after restarting. Users can choose whether to enable this function based on actual needs.
Bluetooth Function
- Install APP: ATK-XTOOL (Only supports Android phones; IOS version is developing).
- DM40 Setup: Go to Settings → Other Settings, turn on the Bluetooth, Pop up prompt precautions and Bluetooth name (wait a few seconds for configuration if first use). Then exit the settings and return to the multimeter measurement interface.
- Enable Bluetooth on your phone and open the ATK-XTOOL app. The app supports up to 4 devices (lag may occur if multi-device connection). Click any one to enter, and the app will automatically scan for nearby devices. Select the device starting with “DM40” (default Bluetooth name is the same as the model). After successful connection, the measured values will be previewed. Click to enter the full-featured interface. Once connected, a Bluetooth icon will appear in the status bar of the DM40 If no device starting with “DM40” is found, restore to the factory settings and repeat this step.
- The buttons at the bottom of the app interface have the same functions as the DM40 touch buttons. The circled Bluetooth icon in the status bar is used for quick Bluetooth connection and disconnection. For further clarification, click the “?” icon to view instructions.
- The Bluetooth name can be partially modified, supporting up to 10 characters. The first 5 characters represent the device model and cannot be changed.
Services
After – sales Service
We warrant that the product will be free from defects in materials and workmanship for a period of 1 years from the date of purchase of the product by the original purchaser from our company. This warranty only applies to the original purchaser and is not transferable to a third party.
If the product proves defective during the warranty period, we will either repair the defective product without charge for parts and labour, or will provide a replacement in exchange for the defective product.
This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate maintenance and care.
Website
- Download www.alientek.com/download
- Company : www.alientek.com
- Aliexpress www.aliexpress.com/store/1102909571
Contact US
- Email : fae-smt@alientek.com
Frequently Asked Questions
- Q: Can I use the DM40 in damp conditions?
A: It is not recommended to use the DM40 in damp conditions to prevent damage and ensure safety. - Q: How do I enable the Bluetooth function?
A: Navigate to Settings > Other Settings, turn on Bluetooth, and connect via the ATK-XTOOL app for Bluetooth functionality. - Q: What should I do if I encounter a low battery reminder during measurement?
A: Promptly charge the DM40 to ensure measurement accuracy and stability.
Documents / Resources
![]() |
ALIENTEK DM40A Touchable Multimeter [pdf] User Manual DM40A, DM40B, DM40C, DM40A Touchable Multimeter, DM40A, Touchable Multimeter, Multimeter |