LEF-LD Loudspeaker Intercom System
“
Product Specifications
- Model: LEF-LD
- Product Type: Special Order Loudspeaker Intercom System
- Applications: Long Distance and Elevator
- Available Models: LEF-3-LD, LEF-5-LD, LEF-10-LD, LEF-10S-LD,
LEF-3C-LD, LEF-5C-LD, LEF-10C-LD - Wiring Distance: 22 AWG = 2000′; 18 AWG = 4000′
Product Usage Instructions
System Overview
The LEF-LD system is designed for long-distance communication
and elevator applications. It can operate at greater distances and
supports both surface and flush mount sub stations. The system is
compatible with LEF, LAF-C/CA, or LDF masters modified for Long
Distance.
Wiring Diagrams
Method A – 3 Conductors
Master to each sub station: IE-JA-LD: 1 2 3 LEF-10-LD: 1 2 ~ 10
PS-12C: E + E/- jumper attached on master IF-DA-LD: 1 2
Method B – 2 Conductors with Power
Master to each sub station with power: IE-JA-LD: 1 2 LEF-10-LD:
1 2 ~ 10 IF-DA-LD: 1 2 -* PS-12C: + Negatives of remote + 12V DC *
Negatives of remote power supplies must be tied together.
LEF Master Terminal Definitions
- 1~10: Selective call/communication terminal for each call
button - E: Common communication
Sub Station Mounting and Wiring
IF-DA-LD Sub Station
- 1: Call-in and Communication
- 2: Common
- White: +12V DC (connect to + of PS-12C)
IE-JA-LD Sub Station
- 1: Call-in and Communication
- 2: Common
- +12V DC (connect to + of PS-12C)
FAQ – Frequently Asked Questions
Q: Can I use the LEF-LD system with multiple masters?
A: No, the LEF-LD system is designed for a single master
only.
Q: What is the maximum wiring distance supported by the
system?
A: The system supports up to 2000′ with 22 AWG wiring and up to
4000′ with 18 AWG wiring.
Q: Where can I find complete wiring information for the LEF-LD
system?
A: For detailed wiring instructions, please refer to the
standard LEF, LEF-C, or LAF-C/CA instructions provided by Aiphone
Communication Systems.
“`
LEF-LD
Special Order Products
LEF Loudspeaker Intercom System for Long Distance and Elevator Applications
LEF-3-LD, LEF-5-LD, LEF-10-LD, LEF-10S-LD LEF-3C-LD, LEF-5C-LD, LEF-10C-LD
– INSTRUCTIONS –
The LEF-LD system is designed with the capability to operate at greater distances and for use in elevators. The sub stations are available in either surface or flush mount styles. Any LEF, LAF-C/CA, or LDF master can be modified for Long Distance. NOTE: This is a SINGLE MASTER SYSTEM ONLY.
WIRING DIAGRAMS:
Method A: 3 conductors homerun from master to each sub.
IE-JA-LD 1 2 3
LEF-10-LD
1 2 ~ 10
+
PS-12C
E +
E/- jumper attached on
master
IF-DA-LD 1 2
Wht
Method B: 2 conductors homerun from master to each sub. 12V DC power provided at each sub station location.
*-
IE-JA-LD 1 2
LEF-10-LD
1 2 ~ 10
IF-DA-LD 1
2 -*
Wht
+
* Negatives of remote +
3
power supplies must
be tied together.
12V DC
LEF Master Terminal Definitions:
+
PS-12C
E
–
+
E/- jumper attached on
master
12V DC * Negatives of remote power supplies must be tied together.
1~10 Selective call/communication
terminal for each call button
E
Common communication
IF-DA-LD Mounting:
IE-JA-LD Mounting:
+
12V DC
–
Negative, common call signal
IF-DA-LD Sub Station:
1
Call-in and Communication
2
Common
White +12V DC (connect to + of PS-12C)
IE-JA-LD Sub Station:
1
Call-in and Communication
2
Common
Wiring Distance: 22 AWG = 2000′; 18 AWG = 4000′
3
+12V DC (connect to + of PS-12C)
NOTE:
Only wiring concerning the LEF-LD is shown here.
Aiphone Communication Systems 1700 130th Ave. N.E.
TOLL FREE TECHNICAL SUPPORT: 800-692-0200
For complete wiring information, please see the standard LEF, LEF-C, or LAF-C/CA instructions.
Bellevue, WA 98005
TOLL FREE FAX LINE:
LEF-LD Instr.
FAX 425-455-0071
E-mail: tech-serv@aiphone.com
0100bk
Documents / Resources
![]() | AIPHONE LEF-LD Loudspeaker Intercom System [pdf] User Guide LEF-3-LD, LEF-5-LD, LEF-10-LD, LEF-10S-LD, LEF-3C-LD, LEF-5C-LD, LEF-10C-LD, LEF-LD Loudspeaker Intercom System, LEF-LD, Loudspeaker Intercom System, Intercom System, System |