1. Introduction
The EPEVER LS1024EU is a 12/24V, 10A PWM LandStar Solar Charge Controller designed for efficient and reliable management of solar power systems. This programmable solar charge controller utilizes advanced digital techniques to ensure optimal battery charging and protection. It is an easy-to-operate and cost-effective solution for various off-grid solar applications.
2. Safety Information
- Read all instructions in this manual before installation.
- DO NOT disassemble or attempt to repair the controller.
- Install an external fuse or breaker as required.
- Disconnect the solar module and fuse/breakers near the battery before installing or moving the controller.
- Power connections must remain tight to avoid excessive heating from a loose connection.
- Only charge batteries that comply with the parameters of the controller.
- Battery connection may be wired to one battery or a bank of batteries.
- Risk of electric shock: the PV and load can produce high voltages when the controller is working.
3. Product Overview and Features
The LandStar E series controller, including the LS1024EU, is a PWM charge controller that incorporates advanced digital techniques for efficient operation. Key features include:
- 3-Stage intelligent PWM charging: Bulk, Boost/Equalize, Float.
- Support for 3 charging options: Sealed, Gel, and Flooded batteries.
- Battery status LED indicator to show battery condition.
- Battery temperature compensation function for optimized charging.
- User-friendly settings for comfortable and convenient operation.
- USB output interface (5VDC/1.2A) for charging electronic equipment (LS EU series only).
- Battery type and load output can be set via a button.
- Extensive Electronic protection features.
Component Descriptions:
- PV Terminals
- Battery Terminals
- Load Terminals
- USB output interface (LS E series only)
- Mounting Hole Φ4.5
- Load Switch Button
- Battery status LED indicator
- Load status LED indicator
- Charging status LED indicator
4. Setup and Wiring
Follow these steps to connect the EPEVER LS1024EU solar charge controller to your system. Ensure all connections are secure and correct to prevent damage.
Wiring Steps:
- Connect the battery to the controller's Battery Terminals (labeled 2 in Figure 3-1).
- Connect the load to the controller's Load Terminals (labeled 3 in Figure 3-1).
- Connect the PV array (solar panels) to the controller's PV Terminals (labeled 1 in Figure 3-1).
Important Notes:
- Always connect the system in the order: Battery → Load → PV Array.
- Disconnect the system in the reverse order: PV Array → Load → Battery.
- While wiring, do not close the circuit breaker or fuse.
- Ensure that the leads of "+" and "-" poles are connected correctly.
- A fuse with a current rating of 1.25 to 2 times the rated current of the controller must be installed on the battery side, with a distance from the battery not greater than 150 mm.
- If an inverter is to be connected to the system, connect the inverter directly to the battery, not to the load side of the controller.
5. Operating Instructions
The EPEVER LS1024EU controller is designed for straightforward operation. Here are the basic operating procedures:
5.1 Load Control
- Load Switch Button (6): Press this button to manually turn the connected DC load ON or OFF.
5.2 LED Indicators
Monitor the status of your system using the LED indicators:
- Charging Status LED Indicator (9): Indicates the charging status of the battery (e.g., charging, fully charged).
- Battery Status LED Indicator (7): Displays the current state of charge of the battery (e.g., high, normal, low voltage).
- Load Status LED Indicator (8): Shows whether the load is active, or if there is an overload or short-circuit condition.
5.3 USB Output
- The USB output interface (4) provides a 5VDC/1.2A power supply for charging compatible electronic devices.
5.4 Battery Type Setting
The controller supports three battery types: Sealed, Gel, and Flooded. The specific method for setting the battery type via button is typically detailed in the full product manual. Refer to the device's interface for instructions on cycling through battery types if available.
6. Maintenance
To ensure the longevity and optimal performance of your EPEVER LS1024EU solar charge controller, regular maintenance is recommended:
- Cleanliness: Keep the controller clean and free from dust, dirt, and debris. Use a dry cloth to wipe the exterior.
- Connections: Periodically check all wire connections (PV, battery, load) to ensure they are tight and free from corrosion. Loose connections can lead to overheating and system malfunction.
- Ventilation: Ensure that the controller has adequate ventilation and that its vents are not obstructed. Proper airflow helps dissipate heat and prevents overheating.
- Environmental Check: Verify that the operating environment temperature and humidity remain within the specified ranges.
7. Troubleshooting
If you encounter issues with your EPEVER LS1024EU controller, consider the following common troubleshooting steps:
- No Power/Load Not Working:
- Check all battery connections for tightness and correct polarity.
- Verify the battery fuse is intact and properly installed.
- Ensure the Load Switch Button (6) is pressed to turn the load ON.
- Check the battery voltage; if it's too low, the controller might have entered low voltage disconnect (LVD) mode to protect the battery.
- Battery Not Charging:
- Ensure the PV array is connected correctly to the PV Terminals (1) with correct polarity.
- Check for sufficient sunlight on the solar panels.
- Verify the PV open circuit voltage is within the controller's specifications (Max. PV open circuit voltage: 50V).
- Inspect PV wiring for any breaks or loose connections.
- Overload/Short-circuit Indication:
- If the Load Status LED (8) indicates an error (e.g., flashing or specific error pattern), disconnect the load.
- Check the connected load for any short-circuits or excessive current draw.
- Reconnect the load once the fault is resolved.
8. Specifications (LS1024EU Model)
| Item | Specification (LS1024EU) |
|---|---|
| Nominal system voltage | 12/24VDC Auto |
| Rated charge current | 10A |
| Rated discharge current | 10A |
| Battery input voltage range | 8V~32V |
| Max. PV open circuit voltage | 50V |
| Self-consumption | 12V≤9.6mA; 24V≤10.5mA |
| Charge Circuit Voltage Drop | ≤0.18V |
| Discharge Circuit Voltage Drop | ≤0.26V |
| USB output interface | 5VDC/1.2A |
| Temperature compensation coefficient | -5mV/℃/2V |
| Working environment temperature | -35℃ ~ +50℃ |
| Humidity | ≤95%, (N.C.) |
| Enclosure | IP20 |
| Grounding | Common Positive |
| Overall dimension | 120.3 x 67 x 21.8mm |
| Mounting dimension | 111.5mm |
| Mounting hole size | Φ4.5 |
| Terminals | 12AWG/4mm2 |
| Net weight | 0.10kg |
9. User Tips
Based on general user feedback for similar solar charge controllers, here are some tips:
- Proper Sizing: Ensure your solar panel array and battery bank are appropriately sized for the controller's capacity (10A). Oversizing can damage the controller.
- Battery Compatibility: Always select the correct battery type setting on the controller to match your battery (Sealed, Gel, or Flooded) for optimal charging and battery lifespan.
- Cable Gauge: Use appropriate wire gauges for all connections to minimize voltage drop and ensure safe operation, especially for longer cable runs.
- Environmental Protection: While the LS1024EU has an IP20 enclosure, it is recommended to install it in a dry, well-ventilated area, protected from direct sunlight, rain, and excessive dust.
10. Warranty and Support
For warranty information and technical support, please refer to the official EPEVER website or contact your authorized dealer. Keep your purchase receipt as proof of purchase for any warranty claims.