1. Overview
Thank you for selecting the VS AU series common positive solar charge controller. The VS AU controller is a PWM charge controller with a built-in LCD display that adopts the most advanced digital technique. The multiple load control modes enable it to be widely used in solar home systems, traffic signals, solar street lights, solar garden lamps, etc.
Key features include:
- High-quality components (ST, IR, Infineon) ensuring product lifespan.
- Terminals with UL and VDE certification for enhanced safety and reliability.
- Continuous operation at full load within an environment temperature range from -25 to 55 ℃.
- 3-Stage intelligent PWM charging: Bulk, Boost/Equalize, Float.
- Support for 3 charging options: Sealed, Gel, and Flooded batteries.
- LCD display design, dynamically showing device’s operating data and working condition.
- Double USB design for charging electronic equipment (5VDC/2.4A Total).
- Humanized button settings for comfortable and convenient operation.
- Multiple load control modes.
- Energy statistics function.
- Battery temperature compensation function.
- Extensive Electronic protection.
2. Product Features and Components
The VS AU series controller is designed with user-friendly interfaces and robust components. Refer to the diagram below for an identification of its main parts:
Component identification:
| No. | Component | No. | Component |
|---|---|---|---|
| ① | LCD | ⑤ | Battery Terminals |
| ② | MENU Button | ⑥ | Load Terminals |
| ③ | RTS Port | ⑦ | SET Button |
| ④ | PV Terminals | ⑧ | USB Output Ports |
3. Setup and Wiring
Proper wiring is crucial for the safe and efficient operation of your solar charge controller. Please follow these steps carefully:
- Connect components in sequence: Connect all components to the charge controller in the following order: Battery, PV (Solar Panel), and then Load. Pay close attention to the “+” and “-” polarities.
- Safety Precaution: Do NOT insert the fuse or turn on any breakers during the initial installation process.
- Disconnection Order: When disconnecting the system, reverse the order: first disconnect the Load, then PV, and finally the Battery.
- Initial Power-On: After connecting the battery, check if the LCD on the controller powers on. If not, refer to the troubleshooting section. Always connect the battery first to allow the controller to recognize the system voltage (12V/24V auto-detection).
- Battery Fuse: The battery fuse should be installed as close to the battery as possible. The suggested distance is within 150mm.
- Grounding: The VS AU series is a common positive ground controller. Any positive connection of the solar panel, load, or battery can be earth grounded as required.
Important: Ensure all connections are secure and correct before applying power to prevent damage to the controller or other components.
4. Operating Instructions
The VS AU series controller features an intuitive LCD display and two buttons (MENU and SET) for operation.
4.1 LCD Display
The LCD dynamically displays real-time operating data and the working status of the device. This includes battery voltage, charging current, load current, and various system parameters.
4.2 Button Functions
- MENU Button: Used to navigate through different display screens and menu options. A short press typically cycles through display pages, while a long press may enter or exit a menu.
- SET Button: Used to confirm selections, modify parameters, or adjust settings within a menu. A short press might change a value, and a long press might save a setting.
4.3 Basic Operation
- View Parameters: Short press the MENU button to cycle through various display screens showing battery voltage, PV voltage, charging current, load current, and other system information.
- Enter Setting Mode: Long press the SET button to enter the parameter setting mode. The currently adjustable parameter will typically blink.
- Adjust Parameters: While in setting mode, use the MENU button to change the value of the blinking parameter.
- Confirm and Save: Short press the SET button to confirm the new value and move to the next parameter. Long press the SET button to save all changes and exit the setting mode.
- Load Control: The controller supports multiple load control modes (e.g., always on, dusk to dawn, timer). These can be configured in the setting mode to suit your application.
5. Maintenance
To ensure optimal performance and longevity of your EPever VS AU series solar charge controller, regular maintenance is recommended:
- Check Connections: Periodically inspect all wiring connections to ensure they are tight and free from corrosion. Loose connections can cause voltage drops and overheating.
- Clean the Controller: Keep the controller clean and free from dust, dirt, and debris. Use a dry cloth to wipe the exterior. Do not use liquids or solvents.
- Inspect for Damage: Visually inspect the controller for any signs of physical damage, such as cracks, loose terminals, or discolored components.
- Ventilation: Ensure that the controller's ventilation openings are not obstructed to allow for proper heat dissipation.
- Battery Inspection: Regularly check the battery terminals for corrosion and ensure the battery is in good condition. For flooded batteries, check electrolyte levels.
6. Troubleshooting
If you encounter issues with your solar charge controller, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Controller LCD is off / No power |
|
|
| No charging from PV |
|
|
| Load not working |
|
|
7. Technical Specifications
The following table details the technical specifications for the VS AU series, with specific values for the VS2024AU model highlighted.
| Item | VS1024AU | VS2024AU | VS3024AU | VS3048AU | VS4524AU | VS4548AU | VS6024AU | VS6048AU |
|---|---|---|---|---|---|---|---|---|
| Nominal system voltage | 12/24VDC Auto | 12/24/36/48VDC Auto | 12/24VDC Auto | 12/24/36/48VDC Auto | 12/24VDC Auto | 12/24/36/48VDC Auto | ||
| Battery input voltage range | 9V~32V | 9V~64V | 9V~32V | 9V~64V | 9V~32V | 9V~64V | ||
| Rated charge/discharge current | 10A@55℃ | 20A@55℃ | 30A@55℃ | 45A@55℃ | 60A@55℃ | |||
| Max. PV open circuit voltage | 50V | 96V | 50V | 96V | 50V | 96V | ||
| Battery type | Sealed(Default) / Gel / Flooded | |||||||
| Equalize Charging Voltage※ | Sealed:14.6V/ Gel: No/ Flooded:14.8V | |||||||
| Boost Charging Voltage※ | Sealed:14.4V/ Gel:14.2V/ Flooded:14.6V | |||||||
| Float Charging Voltage※ | Sealed/Gel/Flooded:13.8V | |||||||
| Low Voltage Reconnect Voltage※ | Sealed/Gel/Flooded:12.6V | |||||||
| Low Voltage Disconnect Voltage※ | Sealed/Gel/Flooded:11.1V | |||||||
| Self-consumption | ≤9.2mA/12V;≤11.7mA/24V; ≤14.5mA/36V;≤17mA/48V | |||||||
| Temperature compensation coefficient | -3mV/℃/2V(25℃) | |||||||
| Charge circuit voltage drop | ≤0.29V | |||||||
| Discharge circuit voltage drop | ≤0.16V | |||||||
| LCD temperature range | -20℃~+70℃ | |||||||
| Working environment temperature | -25℃~+55℃(Product can work continuously at full load) | |||||||
| Relative humidity | ≤95%, N.C. | |||||||
| Enclosure | IP30 | |||||||
| Grounding | Common Positive | |||||||
| USB output | 5VDC/2.4A(Total) | |||||||
| Overall dimension | 142x85x41.5mm | 160x94.9x49.3mm | 181x100.9x59.8mm | 194x118.4x63.8mm | 214x128.7x72.2mm | |||
| Mounting dimension | 130x60mm | 148x70mm | 172x80mm | 185x90mm | 205x100mm | |||
| Mounting hole size | Φ4.5mm | Φ5mm | Φ5mm | Φ5mm | ||||
| Terminals | 4mm2/12AWG | 10mm2/8AWG | 16mm2/6AWG | 16mm2/6AWG | 25mm2/4AWG | |||
| Net weight | 0.22kg | 0.35kg | 0.55kg | 0.58kg | 0.76kg | 0.88kg | 1.02kg | 1.04kg |
| ※Above the parameters are in 12V system at 25℃, twice in 24V system, triple in 36V system and quadruple in 48V system. | ||||||||
Note: This page specifically details the 12V/24V PV50V model (VS2024AU).
8. User Tips
- Battery Type Selection: Always ensure the correct battery type (Sealed, Gel, or Flooded) is selected in the controller settings to optimize charging and prolong battery life.
- Cable Sizing: Use appropriately sized cables for your PV array, battery, and load connections to minimize voltage drop and ensure efficient power transfer. Refer to the specifications for recommended terminal sizes.
- Environmental Considerations: While the controller is designed for a wide temperature range, avoid installing it in direct sunlight or extremely humid environments to prevent overheating and potential damage.
- USB Port Usage: The dual USB ports are convenient for charging small electronic devices. Be mindful of the total 2.4A output limit to avoid overloading.
9. Warranty and Support
For detailed warranty information, technical support, or service inquiries, please contact the seller or the manufacturer directly. Keep your purchase receipt as proof of purchase.
The manufacturer's website or the seller's product page may provide additional resources, FAQs, and contact information for support.