1. Overview

Thank you for selecting the VS AU series common positive solar charge controller. The VS AU controller is a PWM charge controller with a built-in LCD display that adopts the most advanced digital technique. The multiple load control modes enable it to be widely used in solar home systems, traffic signals, solar street lights, solar garden lamps, etc.

Key features include:

  • High-quality components (ST, IR, Infineon) ensuring product lifespan.
  • Terminals with UL and VDE certification for enhanced safety and reliability.
  • Continuous operation at full load within an environment temperature range from -25 to 55 ℃.
  • 3-Stage intelligent PWM charging: Bulk, Boost/Equalize, Float.
  • Support for 3 charging options: Sealed, Gel, and Flooded batteries.
  • LCD display design, dynamically showing device’s operating data and working condition.
  • Double USB design for charging electronic equipment (5VDC/2.4A Total).
  • Humanized button settings for comfortable and convenient operation.
  • Multiple load control modes.
  • Energy statistics function.
  • Battery temperature compensation function.
  • Extensive Electronic protection.
EPever VS2024AU Solar Charge Controller front view
Front view of the EPever VS2024AU Solar Charge Controller.

2. Product Features and Components

The VS AU series controller is designed with user-friendly interfaces and robust components. Refer to the diagram below for an identification of its main parts:

Diagram of EPever VS4524AU controller with numbered components
Figure 1: Characteristic features of the controller.

Component identification:

No. Component No. Component
① LCD ⑤ Battery Terminals
② MENU Button ⑥ Load Terminals
③ RTS Port ⑦ SET Button
④ PV Terminals ⑧ USB Output Ports

3. Setup and Wiring

Proper wiring is crucial for the safe and efficient operation of your solar charge controller. Please follow these steps carefully:

Wiring diagram for EPever solar charge controller showing connections for PV, Battery, Load, and Inverter
Wiring diagram for the solar charge controller.
  1. Connect components in sequence: Connect all components to the charge controller in the following order: Battery, PV (Solar Panel), and then Load. Pay close attention to the “+” and “-” polarities.
  2. Safety Precaution: Do NOT insert the fuse or turn on any breakers during the initial installation process.
  3. Disconnection Order: When disconnecting the system, reverse the order: first disconnect the Load, then PV, and finally the Battery.
  4. Initial Power-On: After connecting the battery, check if the LCD on the controller powers on. If not, refer to the troubleshooting section. Always connect the battery first to allow the controller to recognize the system voltage (12V/24V auto-detection).
  5. Battery Fuse: The battery fuse should be installed as close to the battery as possible. The suggested distance is within 150mm.
  6. Grounding: The VS AU series is a common positive ground controller. Any positive connection of the solar panel, load, or battery can be earth grounded as required.

Important: Ensure all connections are secure and correct before applying power to prevent damage to the controller or other components.

4. Operating Instructions

The VS AU series controller features an intuitive LCD display and two buttons (MENU and SET) for operation.

4.1 LCD Display

The LCD dynamically displays real-time operating data and the working status of the device. This includes battery voltage, charging current, load current, and various system parameters.

4.2 Button Functions

  • MENU Button: Used to navigate through different display screens and menu options. A short press typically cycles through display pages, while a long press may enter or exit a menu.
  • SET Button: Used to confirm selections, modify parameters, or adjust settings within a menu. A short press might change a value, and a long press might save a setting.

4.3 Basic Operation

  1. View Parameters: Short press the MENU button to cycle through various display screens showing battery voltage, PV voltage, charging current, load current, and other system information.
  2. Enter Setting Mode: Long press the SET button to enter the parameter setting mode. The currently adjustable parameter will typically blink.
  3. Adjust Parameters: While in setting mode, use the MENU button to change the value of the blinking parameter.
  4. Confirm and Save: Short press the SET button to confirm the new value and move to the next parameter. Long press the SET button to save all changes and exit the setting mode.
  5. Load Control: The controller supports multiple load control modes (e.g., always on, dusk to dawn, timer). These can be configured in the setting mode to suit your application.

5. Maintenance

To ensure optimal performance and longevity of your EPever VS AU series solar charge controller, regular maintenance is recommended:

  • Check Connections: Periodically inspect all wiring connections to ensure they are tight and free from corrosion. Loose connections can cause voltage drops and overheating.
  • Clean the Controller: Keep the controller clean and free from dust, dirt, and debris. Use a dry cloth to wipe the exterior. Do not use liquids or solvents.
  • Inspect for Damage: Visually inspect the controller for any signs of physical damage, such as cracks, loose terminals, or discolored components.
  • Ventilation: Ensure that the controller's ventilation openings are not obstructed to allow for proper heat dissipation.
  • Battery Inspection: Regularly check the battery terminals for corrosion and ensure the battery is in good condition. For flooded batteries, check electrolyte levels.

6. Troubleshooting

If you encounter issues with your solar charge controller, refer to the following common problems and solutions:

Problem Possible Cause Solution
Controller LCD is off / No power
  • Battery not connected or reverse polarity.
  • Battery voltage too low.
  • Loose battery connection.
  • Check battery connections and polarity.
  • Charge battery externally if voltage is below minimum operating level.
  • Tighten battery terminal connections.
No charging from PV
  • PV panel not connected or reverse polarity.
  • Insufficient sunlight.
  • PV open circuit voltage too low.
  • Blown fuse in PV circuit.
  • Check PV connections and polarity.
  • Ensure panels are in direct sunlight.
  • Verify PV voltage is within specifications.
  • Check and replace PV fuse if necessary.
Load not working
  • Load not connected or reverse polarity.
  • Load control mode settings.
  • Overload or short circuit on load terminals.
  • Battery voltage too low (LVD activated).
  • Check load connections and polarity.
  • Adjust load control mode settings via the controller's menu.
  • Remove overload/short circuit; controller will automatically recover.
  • Charge battery until LVR (Low Voltage Reconnect) is met.

7. Technical Specifications

The following table details the technical specifications for the VS AU series, with specific values for the VS2024AU model highlighted.

Item VS1024AU VS2024AU VS3024AU VS3048AU VS4524AU VS4548AU VS6024AU VS6048AU
Nominal system voltage 12/24VDC Auto 12/24/36/48VDC Auto 12/24VDC Auto 12/24/36/48VDC Auto 12/24VDC Auto 12/24/36/48VDC Auto
Battery input voltage range 9V~32V 9V~64V 9V~32V 9V~64V 9V~32V 9V~64V
Rated charge/discharge current 10A@55℃ 20A@55℃ 30A@55℃ 45A@55℃ 60A@55℃
Max. PV open circuit voltage 50V 96V 50V 96V 50V 96V
Battery type Sealed(Default) / Gel / Flooded
Equalize Charging Voltage※ Sealed:14.6V/ Gel: No/ Flooded:14.8V
Boost Charging Voltage※ Sealed:14.4V/ Gel:14.2V/ Flooded:14.6V
Float Charging Voltage※ Sealed/Gel/Flooded:13.8V
Low Voltage Reconnect Voltage※ Sealed/Gel/Flooded:12.6V
Low Voltage Disconnect Voltage※ Sealed/Gel/Flooded:11.1V
Self-consumption ≤9.2mA/12V;≤11.7mA/24V; ≤14.5mA/36V;≤17mA/48V
Temperature compensation coefficient -3mV/℃/2V(25℃)
Charge circuit voltage drop ≤0.29V
Discharge circuit voltage drop ≤0.16V
LCD temperature range -20℃~+70℃
Working environment temperature -25℃~+55℃(Product can work continuously at full load)
Relative humidity ≤95%, N.C.
Enclosure IP30
Grounding Common Positive
USB output 5VDC/2.4A(Total)
Overall dimension 142x85x41.5mm 160x94.9x49.3mm 181x100.9x59.8mm 194x118.4x63.8mm 214x128.7x72.2mm
Mounting dimension 130x60mm 148x70mm 172x80mm 185x90mm 205x100mm
Mounting hole size Φ4.5mm Φ5mm Φ5mm Φ5mm
Terminals 4mm2/12AWG 10mm2/8AWG 16mm2/6AWG 16mm2/6AWG 25mm2/4AWG
Net weight 0.22kg 0.35kg 0.55kg 0.58kg 0.76kg 0.88kg 1.02kg 1.04kg
※Above the parameters are in 12V system at 25℃, twice in 24V system, triple in 36V system and quadruple in 48V system.

Note: This page specifically details the 12V/24V PV50V model (VS2024AU).

8. User Tips

  • Battery Type Selection: Always ensure the correct battery type (Sealed, Gel, or Flooded) is selected in the controller settings to optimize charging and prolong battery life.
  • Cable Sizing: Use appropriately sized cables for your PV array, battery, and load connections to minimize voltage drop and ensure efficient power transfer. Refer to the specifications for recommended terminal sizes.
  • Environmental Considerations: While the controller is designed for a wide temperature range, avoid installing it in direct sunlight or extremely humid environments to prevent overheating and potential damage.
  • USB Port Usage: The dual USB ports are convenient for charging small electronic devices. Be mindful of the total 2.4A output limit to avoid overloading.

9. Warranty and Support

For detailed warranty information, technical support, or service inquiries, please contact the seller or the manufacturer directly. Keep your purchase receipt as proof of purchase.

The manufacturer's website or the seller's product page may provide additional resources, FAQs, and contact information for support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.