1. Introduction
Thank you for choosing the HoldPeak HP-870P Digital Power Clamp Meter. This intelligent AC/DC clamp multimeter is a portable, auto-ranging device designed for safe and accurate electrical measurements in various applications. It features a large LCD display for clear readings and a robust design for professional use. This manual provides essential information for the safe and efficient operation of your device.

2. Safety Information
To ensure safe operation and prevent personal injury or damage to the meter, please read and follow all safety instructions carefully.
- Always observe general safety rules for electrical work.
- Do not use the meter if it is damaged or if the insulation around the terminals is broken.
- Do not apply voltage or current exceeding the rated maximum values.
- Before making resistance, diode, or continuity tests, ensure the circuit under test is de-energized.
- Exercise extreme care to avoid electric shock and personal injury.
- Remove the battery when the meter is not in use for extended periods.
- Only use replacement parts of the same type, model number, and electrical specifications.
3. Product Overview
3.1 Key Features
- Power measurement (AC/DC)
- Apparent power measurement
- Power factor measurement
- Active energy measurement
- Temperature measurement
- Data hold function
- Backlight for improved visibility
- AC/DC current and voltage measurement
- Auto-ranging for ease of use
- Jaw Caliber: 45mm

3.2 Button Introduction

- Rotary Switch: Used to select the desired measurement function (e.g., DC/AC Power, AC Power, DC kW, Cosφ, V/Hz, A/Hz, OFF).
- HOLD Key: Freezes the current reading on the display.
- SELECT Key: Toggles between different measurement modes within a single rotary switch position (e.g., AC/DC current, AC/DC kWh, temperature units). Also turns on the backlight with a long press.
- MAX/MIN Key: Displays the maximum or minimum measured value.
- CLEAR Key: Clears saved data or resets functions.
- Back Light Key: Activates the display backlight.
- LCD Display: Shows measurement readings and indicators.
- V Input Jack: For voltage measurements.
- COM Input Jack: Common terminal for most measurements.
- Temperature Input Jack: For connecting the temperature probe.
4. Setup
4.1 Installing Test Leads and Temperature Probe
The HP-870P comes with a pair of test leads (red and black) and a temperature probe. Follow these steps to prepare your meter for use:
- Ensure the meter is turned OFF.
- For voltage, resistance, capacitance, or frequency measurements, insert the red test lead into the 'V' input jack and the black test lead into the 'COM' input jack.
- For temperature measurements, insert the temperature probe into the dedicated temperature input jacks (T+ and T-COM).
- For current measurements using the clamp, no test leads are required.

5. Operating Instructions
The HP-870P offers a variety of measurement functions. Always ensure the correct function is selected before taking a measurement.
5.1 AC and DC Current Measurement
To measure AC or DC current, rotate the dial to the corresponding '≈A' (AC current) or 'A' (DC current) position. Clamp the jaws around a single conductor. The display will show the current reading. For DC current, you may need to press and hold the 'SELECT' button to switch to the DC gear.

5.2 AC and DC Voltage Measurement
Rotate the dial to the '≈V/Hz' (AC voltage) or 'V' (DC voltage) position. Connect the test leads to the circuit in parallel. The display will show the voltage reading. Use the 'SELECT' button to toggle between AC and DC voltage if needed.
5.3 Power Measurement (Active, Reactive, Apparent) and Power Factor
Rotate the dial to the 'AC POWER' position for AC power measurements or 'DC kW' for DC power. Use the 'SELECT' button to cycle through Active Power (kW), Reactive Power (kVAr), Apparent Power (kVA), and Power Factor (Cosφ) measurements. Connect the test leads appropriately for voltage and clamp the jaws around the current-carrying conductor.

5.4 Temperature Measurement
Rotate the dial to the '°F/°C' position. Connect the temperature probe to the dedicated jacks. The display will show the temperature reading in either Fahrenheit or Celsius, which can be toggled using the 'SELECT' button.

5.5 Video Demonstration
6. Specifications
| Feature | Specification |
|---|---|
| Brand Name | HoldPeak |
| Model Number | HP-870P |
| DIY Supplies | Electrical |
| Display Type | Digital Only (9999 counts) |
| Range Select | AUTO |
| Jaw Caliber | 45mm |
| Dimensions | 225*97*40mm |
| Weight | 450g |
| Battery Included | No |
| Operating Temperature | -20~1370°C |
| Measuring Current Range | 1-999.9A (Accuracy: ±(2.5%+15 digits), Resolution: 0.1A) |
| Measuring Voltage Range | 1V-600V (Accuracy: ±(1.0%+8 digits), Resolution: 0.1V) |
| Measuring Resistance Range | 0-60MΩ |
| Measuring Capacitance Range | 0-60mF |
| Active Power | 99.99kW/100kW~300kW |
| Apparent Power | 99.99KVA/100KVA~245KVA |
| Reactive Power | 0.01VAr~99.99KVAr/99.99KVAr~120KVAr |
| Power Factor | 0.3~1.0 |
| Active Energy | 0~99.99kWh/100~700.0kWh (Accuracy: ±(3%+15 digits) for 0-99.99kWh, Resolution: 0.01kWh) |
| MAX/MIN Function | YES |
| Back Light | YES |
7. Maintenance
Proper maintenance ensures the longevity and accuracy of your HoldPeak HP-870P Power Clamp Meter.
- Cleaning: Use a soft, dry cloth to clean the meter. Do not use abrasives or solvents.
- Storage: When not in use, store the meter in its carrying case in a dry, cool place, away from direct sunlight.
- Battery Replacement: If the battery indicator appears on the display, replace the batteries promptly to ensure accurate readings. Refer to the manual for battery type and replacement procedure.
- Calibration: For professional accuracy, periodic calibration by a qualified technician is recommended.
8. Troubleshooting
If you encounter issues with your HP-870P, please refer to the following common problems and solutions:
- No Display/Faint Display: Check battery levels and replace if necessary. Ensure the meter is turned ON.
- Inaccurate Readings: Verify that the correct function is selected for the measurement. Ensure test leads are properly connected and not damaged. Check for external interference.
- Display Viewing Angle: Due to the special function of the IC, the display viewing angle of the product HP-870P clamp meter has certain limitations. For the convenience of the user, the angle is set to the front 45° angle as the best, but it will have some influence when viewing the screen from above. This is normal, not a product failure.
- Meter Not Responding: Try turning the meter off and on again. If the issue persists, remove the batteries for a few minutes and then reinsert them.

9. User Tips
- The power factor measurement range is 0.3 to 1.0, providing flexibility for various electrical systems.
- Benefit from the auto-ranging feature, which automatically selects the appropriate measurement range, simplifying operation.
- The built-in backlight ensures clear visibility of readings even in dimly lit environments.
10. Warranty and Support
For any questions or requests regarding your HoldPeak HP-870P Power Clamp Meter, please feel free to contact HoldPeak customer support. Keep your purchase records for warranty claims.