1. Overview
The Tracer BP solar charge controller adopts advanced Maximum Power Point Tracking (MPPT) charging technology to increase system charging efficiency and lower system cost. This controller supports various battery types, including sealed, gel, flooded, and lithium batteries. Users can monitor and modify operational status and parameters. It is suitable for solar home systems, traffic signals, solar street lights, and solar garden lamps.
Key Features:
- Adopt high-quality components of ST, IR, and Infineon to ensure product lifespan.
- Wider working environment temperature.
- Applicable to lead-acid battery and lithium battery.
- Lithium battery self-activating and low-temperature protection function.
- Maximum conversion efficiency of 98%.
- Advanced Maximum Power Point Tracking (MPPT) technology, with tracking efficiency no less than 99%.
- Accurately recognizing and tracking multiple power points.
- PV power limitation function.
- Monitoring and setting parameters via Mobile APP, PC software.
- Adopt standard Modbus communication protocol for RS485 bus connections to get better communication protocol compatibility.
- Connecting the IoT (Internet of Things) module and Cloud Server monitoring software to realize remote monitoring.
- The RS485 connector can provide a power supply.
- Aluminum housing for better cooling.
- Real-time energy statistics function.
- IP68 waterproof degree.
2. Safety Information
Please read all instructions carefully before installation and pay attention to the following safety guidelines:
- DO NOT disassemble or attempt to repair the controller.
- Install external fast-acting fuse or breaker as required.
- Disconnect the solar module and fast-acting fuse/breakers near to the battery before installing or moving the controller.
- Power connections must remain tight to avoid excessive heating from a loose connection.
- Only batteries that comply with the controller's parameters can be charged.
- Battery connection may be wired to one battery or a bank of batteries.
- Risk of electric shock: the PV and load may produce high voltages when the controller is running.
- Do not install this product in humid, salt spray, corrosion, greasy, flammable, explosive, dust accumulative, or other severe environments.
3. Setup and Wiring
Initial Setup:
- Connect components to the controller in the sequence: Battery > Load > PV. Pay close attention to the '+' and '-' terminals.
- Do not insert the fast-acting fuse or turn on the breaker during the initial installation.
- After powering the controller, the battery LED indicator shall flash green. If it's not green, refer to the Troubleshooting section.
- Connect a fast-acting fuse in series through the battery positive (+) in the circuit. The battery fast-acting fuse must be 1.25 to 2 times the rated current. The installed distance is within 150mm.
Wiring Connection Sequence:
The general connection sequence is as follows:
- Connect the battery to the controller.
- Connect the load to the controller.
- Connect the PV array to the controller.
When disconnecting the system, reverse the order.
Controller Models:
4. Operation
Load Self-Test Function:
The load is automatically turned ON after powering on the controller for 10 seconds. After the load remains ON for 10 seconds, the controller restores to the set working mode.
LED Indicators:
The controller features LED indicators to provide status feedback. Refer to the table below for details:
| Indicator | Color | Status | Instruction |
|---|---|---|---|
| PV | Green | On Solid | PV connection normal but low voltage (irradiance) from PV, no charging |
| OFF | No PV voltage (night time) or PV connection problem | ||
| BATT | Green | Slowly Flashing (1Hz) | In charging |
| Fast Flashing (4Hz) | PV overvoltage | ||
| On Solid | Battery is normal / Battery charges full | ||
| Orange | On Solid | Battery undervoltage / Battery overdischarged | |
| Fast Flashing (4Hz) | Battery overheating / Lithium battery low temperature | ||
| Charging indicator (green) and battery indicator (orange) flashing simultaneously | System voltage error* | ||
*When the battery type is a lithium battery, the controller does not recognize the system voltage automatically.
Load Working Modes:
The controller supports various load working modes:
- Manual Mode (Default ON): The load is controlled manually.
- Light ON/OFF: The load turns on when it detects light and turns off when it detects darkness.
- Light ON + Timer: The load turns on when it detects light and stays on for a set duration (timer).
- Real-time Control: Control the load ON/OFF time by setting a real-time clock.
CAUTION:
- In the mode of Light ON/OFF and Light ON/Timer, the Load is turned on after 10 minutes delay.
5. Maintenance
To ensure optimal performance and longevity of your EPEVER Tracer BP solar charge controller, regular maintenance is recommended:
- Check Connections: Periodically inspect all wiring connections to ensure they are tight and free from corrosion. Loose connections can lead to excessive heating and system inefficiencies.
- Clean Controller: Keep the controller clean and free from dust and debris. Use a dry cloth to wipe the exterior. Do not use harsh chemicals or solvents.
- Inspect for Damage: Regularly check the controller for any signs of physical damage, such as cracks, loose parts, or discolored areas.
- Environment Check: Ensure the installation environment remains within the specified operating conditions (temperature, humidity, etc.) and free from corrosive substances.
- Software Updates: If using monitoring software, check for any available updates to ensure optimal performance and access to the latest features.
6. Troubleshooting
This section provides guidance on common issues and their solutions.
| Faults | Possible Reasons | Troubleshooting |
|---|---|---|
| LED Charging indicator turns off during daytime when sunshine falls on PV modules properly | PV array disconnection | Confirm that PV and battery wire connections are correct and tight. |
| No LED indicator | Battery voltage may be less than 8.5V | Measure battery voltage with a multimeter. Min. 8.5V can start up the controller. |
| Battery LED indicator green fast Flashing | Battery overvoltage | Check if the battery voltage is higher than OVD, and disconnect the PV. |
| Battery LED indicator red | Battery over-discharged | When the battery voltage is restored to or above the LVR point (low voltage reconnect voltage), the load will recover. |
| Battery LED indicator red flashing | Battery Overheating | The controller will automatically turn the system off. But while the temperature declines to be below 50°C, the controller will resume. |
| Load is not output | Load Overload |
|
| Load Short Circuit |
|
Note:
- When it is overload or short circuit, the load has 5 times auto-recovery output function, which each time delays respectively 5s, 10s, 15s, 20s, 25s.
7. Technical Specifications
Below are the detailed technical specifications for the Tracer-BP series controllers, including Tracer2606BP and Tracer2610BP models.
Note: Any changes are subject to prior notice. Version number: V3.6
8. User Tips
No specific user reviews or Q&A content were provided to generate user tips at this time. Always ensure proper ventilation around the controller for optimal performance and longevity.
9. Warranty and Support
Disclaimer (Warranty Exclusions):
This warranty does not apply under the following conditions:
- Damage from improper use or use in an unsuitable environment.
- PV or load current, voltage, or power exceeds the rated value of the controller.
- The controller's working temperature exceeds the limit working environment temperature.
- User disassembly or attempted to repair the controller without permission.
- The controller is damaged due to natural elements such as lightning.
- The controller is damaged during transportation and shipment.
Optional Accessories and Software:
For additional support and monitoring capabilities, EPEVER offers:
- EPEVER Cloud-PC Website: Access monitoring and management tools at https://hncloud.epsolarpv.com/
- EPEVER Cloud-APP: Download the mobile application for iOS and Android devices.
- For details on EPEVER cloud, refer to the Solar Guardian user manual.
- Note that MT52 and eLOG01-G3 are not waterproof. If used outdoors, ensure proper waterproofing and dust protection. MT52 cannot set the relevant parameters of the lithium battery and load mode.
A detailed user manual in PDF format is available for download: View User Manual (PDF)