1. Product Overview
The EPEVER XTRA-N G3/XTRA-N G3 BLE series solar charge controller is designed with advanced Maximum Power Point Tracking (MPPT) control algorithms to maximize energy harvest from PV arrays. It features a built-in Bluetooth module (for BLE series) for convenient parameter reading and adjustment via a phone application. The controller offers independent voltage regulation, supporting various lithium batteries and ensuring low self-consumption to extend system standby time. It incorporates charging power/current limits and automatic power reduction under high temperatures for system stability. With IP33 ingress protection and an isolated RS485 communication port, it is reliable for diverse applications like RVs, household systems, and monitoring fields.
Key Features:
- High-quality components (ST, TI, Infineon) for extended service life.
- Advanced MPPT technology with ultra-fast tracking speed, up to 99.5% tracking efficiency.
- Maximum DC/DC transfer efficiency up to 98.5%; full load efficiency up to 97.2%.
- Advanced MPPT control algorithm minimizes power loss and tracking time.
- Accurate recognition and tracking of multi-peak maximum power points.
- Wide range of MPP operating voltage for optimized PV utilization.
- Supports multiple battery types, including lithium batteries, with stable self-activation.
- Battery temperature compensation.
- Charging power and current limits to prevent overcharging.
- Real-time energy statistics function.
- Automatic charging power reduction for over-temperature conditions.
- Built-in Bluetooth (XTRA-N G3 BLE series) for APP-based settings.
- RS485 communication interface with optional 4G or Wi-Fi modules for remote monitoring.
- Parameter setting via PC software, APP, or remote meter.
- Constant voltage output function.
- Comprehensive electronic protections.
- Multiple load work modes.
- Dust-proof and waterproof design with IP33 enclosure.
- Low self-consumption (less than 10mA after disabling communication port).
- Full load operation without charging power reduction within the working temperature range.
For a detailed PDF version of this manual, please refer to the official document: EPEVER XTRA Series User Manual (PDF)
2. Important Safety Instructions
Please keep this manual for future reference. This manual contains safety, installation, and operation instructions for the XTRA-N G3 or XTRA-N G3 BLE series MPPT solar charge controller.
2.1 General Safety
- Read all instructions and warnings carefully before installation and operation.
- No user-serviceable components exist inside the controller. Do not disassemble or attempt to repair the controller.
- Mount the controller indoors. Avoid exposure to components and do not allow water to enter the controller.
- Install the controller in a well-ventilated place. The controller's heat sink may become very hot during operation.
- It is suggested to install appropriate external fast-acting fuses/breakers.
- Disconnect all PV array connections and fast-acting fuses/breakers before controller installation and adjustment.
- Power connections must remain tight to avoid excessive heating from a loose connection.
NOTICE:
Do not install the controller in humid, high salt spray, corrosion, greasy, flammable, explosive, dust accumulative, or other severe environments.
2.2 Other Safety Instructions (FCC Compliance)
- Changes or modifications to this equipment not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
- This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
- If this equipment causes harmful interference to radio or television reception, try to correct the interference by reorienting or relocating the receiving antenna, increasing the separation between the equipment and receiver, or connecting the equipment to an outlet on a different circuit.
- This equipment complies with Part 15 of the FCC Rules and has license-exempt transmitter/receiver in line with License-Exempt RSS of Innovation, Science and Economic Development Canada. Operation is subject to two conditions: (1) the controller may not cause interference, and (2) the controller must accept any interference, including interference that may cause undesired operation.
3. Product Appearance and Naming Rules
3.1 Controller Layout

Figure: EPEVER XTRA MPPT Solar Charge Controller

Figure: LCD Display Cycle
3.2 Component Identification

Figure: Controller Components
| No. | Description | No. | Description |
|---|---|---|---|
| 1 | RTS port (Remote Temperature Sensor) | 5 | RS485 communication port |
| 2 | PV terminals | 6 | Terminal protection cover |
| 3 | Battery terminals | 7 | Display units |
| 4 | Load terminals | 8 | Mounting hole (5mm) |
Note: If the temperature sensor is short-circuited or damaged, the controller will charge or discharge according to the setting voltage at 25°C (no temperature compensation).
3.3 RS485 Communication Port (RJ45)
| Pin | Definition | Instruction | Pin | Definition | Instruction |
|---|---|---|---|---|---|
| 1 | +5VDC | 5V/200mA | 5 | RS485-A | RS485-A |
| 2 | +5VDC | 6 | RS485-A | ||
| 3 | RS485-B | RS485-B | 7 | GND | Power GND |
| 4 | RS485-B | 8 | GND |
3.4 Naming Rules for Models
The model names follow a specific structure:
- XTRA: Product series.
- First two digits (e.g., 12, 22, 32, 34, 42, 44): Rated charging & discharging current (10A, 20A, 30A, 40A).
- Next two digits (e.g., 06, 10, 15): PV maximum open-circuit voltage (60V, 100V, 150V).
- N: Common negative system.
- G3: 3rd generation product.
- BLE: Indicates built-in Bluetooth module (for XTRA-N G3 BLE series only).
4. Installation
4.1 Installation Precautions
- Wear eye protection when installing flooded lead-acid batteries and rinse with clean water if battery acid contact occurs.
- Keep batteries away from metal objects to prevent short circuits.
- Ensure good ventilation as explosive battery gases may be released during charging.
- Avoid direct sunlight and rain infiltration for outdoor installations.
- Ensure tight power connections and secure cables with clamps to prevent high heat from loose connections.
- Only charge lead-acid and lithium-ion batteries within the controller's specified control range.
- Battery connections can be made to a single battery or a bank of batteries.
- Select system cables according to 5A/mm² or less current density.
- The grounding wire size should not be less than 4mm².
- The torque for tightening wiring screws should be at least 1.2 N·m.
4.2 Requirements for the PV Array
The controller supports various PV modules. The number of PV modules in series (string) depends on the open-circuit voltage (Voc) and maximum power point voltage (VMPP) of the MPPT controller. Refer to the tables below for guidance.
NOTICE:
When PV modules are connected in series, the open-circuit voltage of the PV array must not exceed 46V (XTRA ** 06N G3/BLE), 92V (XTRA**10N G3/BLE), or 138V (XTRA ** 15N G3/BLE) at 25°C.
PV Module Stringing (XTRA1206/2206N G3; XTRA1206/2206N G3 BLE)
| System Voltage | 36-cell (Voc < 23V) | 48-cell (Voc < 31V) | 54-cell (Voc < 34V) | 60-cell (Voc < 38V) | ||||
|---|---|---|---|---|---|---|---|---|
| Max. | Best | Max. | Best | Max. | Best | Max. | Best | |
| 12V | 2 | 2 | 1 | 1 | 1 | 1 | 1 | 1 |
| 24V | 2 | 2 | - | - | - | - | - | - |
Note: Parameters are calculated under STC (25°C, 1.5 air mass, 1,000W/m² irradiance).
PV Module Stringing (XTRA1210/2210/3210/4210N G3; XTRA1210/2210/3210/4210N G3 BLE)
| System Voltage | 36-cell (Voc < 23V) | 48-cell (Voc < 31V) | 54-cell (Voc < 34V) | 60-cell (Voc < 38V) | ||||
|---|---|---|---|---|---|---|---|---|
| Max. | Best | Max. | Best | Max. | Best | Max. | Best | |
| 12V | 4 | 2 | 2 | 1 | 2 | 1 | 2 | 1 |
| 24V | 4 | 3 | 2 | 2 | 2 | 2 | 2 | 2 |
Note: Parameters are calculated under STC (25°C, 1.5 air mass, 1,000W/m² irradiance).
PV Module Stringing (XTRA3215/4215N G3; XTRA3215/4215N G3 BLE)
| System Voltage | 36-cell (Voc < 23V) | 48-cell (Voc < 31V) | 54-cell (Voc < 34V) | 60-cell (Voc < 38V) | ||||
|---|---|---|---|---|---|---|---|---|
| Max. | Best | Max. | Best | Max. | Best | Max. | Best | |
| 12V | 4 | 2 | 2 | 1 | 2 | 1 | 2 | 1 |
| 24V | 6 | 3 | 4 | 2 | 4 | 2 | 3 | 2 |
Note: Parameters are calculated under STC (25°C, 1.5 air mass, 1,000W/m² irradiance).
PV Module Stringing (XTRA3415/4415N G3; XTRA3415/4415N G3 BLE)
| System Voltage | 36-cell (Voc < 23V) | 48-cell (Voc < 31V) | 54-cell (Voc < 34V) | 60-cell (Voc < 38V) | ||||
|---|---|---|---|---|---|---|---|---|
| Max. | Best | Max. | Best | Max. | Best | Max. | Best | |
| 12V | 4 | 2 | 2 | 1 | 2 | 1 | 2 | 1 |
| 24V | 6 | 3 | 4 | 2 | 4 | 2 | 3 | 2 |
| 48V | 6 | 5 | 4 | 3 | 4 | 3 | 3 | 3 |
Note: Parameters are calculated under STC (25°C, 1.5 air mass, 1,000W/m² irradiance).
4.3 Wire Size and Circuit Breaker
Wiring and installation must conform to national and local electrical code requirements.
Recommended PV Wire Size
The PV array's short circuit current (ISC) determines the minimum PV wire size. The ISC of the PV array must not exceed the controller's maximum PV input current.
| Model | Max. PV Input Current | Max. PV Wire Size* | Circuit Breaker |
|---|---|---|---|
| XTRA1206/1210N G3 / BLE | 10A | 4mm²/12AWG | 16A/125V/2 P |
| XTRA2206/2210N G3 / BLE | 20A | 6mm²/10AWG | 32A/125V/2 P |
| XTRA3210/3215/3415N G3 / BLE | 30A | 10mm²/8AWG | 40A/125V/2 P |
| XTRA4210/4215/4415N G3 / BLE | 40A | 16mm²/6AWG | 63A/125V/2 P |
Recommended Battery and Load Wire Size
The battery and load wire size must conform to the rated current.
| Model | Rated Charge Current | Rated Discharge Current | Battery Wire Size | Circuit Breaker |
|---|---|---|---|---|
| XTRA1206/1210N G3 / BLE | 10A | 10A | 4mm²/12AWG | 16A/125V/2 P |
| XTRA2206/2210N G3 / BLE | 20A | 20A | 6mm²/10AWG | 32A/125V/2 P |
| XTRA3210/3215/3415N G3 / BLE | 30A | 30A | 10mm²/8AWG | 40A/125V/2 P |
| XTRA4210/4215/4415N G3 / BLE | 40A | 40A | 16mm²/6AWG | 63A/125V/2 P |
NOTICE:
- The wire size is for reference only. For long distances between the PV array, controller, and battery, use larger wires to reduce voltage drop.
- The recommended battery wire is selected when the battery terminals are not connected to any additional inverter.
4.4 Mounting and Wiring the Controller
DANGER:
- Risk of explosion! Never install the controller in an enclosed space with flooded batteries or where battery gas can accumulate.
- Electric shock hazard! The PV array may generate very high open circuit voltage. Disconnect the circuit breaker or fast-acting fuse first before wiring.
NOTICE:
Ensure sufficient airflow around the controller's heat sink. Leave at least 150mm clearance above and below for natural convection. If mounted in a closed cabinet, ensure heat can be dissipated.
Step 1: Determine Installation Location and Heat Dissipation Space
Install the controller in a location with sufficient airflow. Maintain a minimum clearance of 150mm from the upper and lower edges for natural thermal convection.

Figure: Recommended Clearances for Heat Dissipation
Step 2: Connect the System
Connect the system in the order of battery > load > PV array. Disconnect in the reverse order.

Figure: Battery Mode Connection (without BMS-Link)

Figure: Battery Mode Connection (with BMS-Link)
NOTICE:
- Do not connect the circuit breaker or fast-acting fuse while wiring. Ensure correct electrode polarity.
- A fast-acting fuse (1.25 to 2 times the rated current of the controller) must be installed on the battery side, no more than 150mm from the battery.
- Battery cable length should not exceed 3 meters.
- PV array cable length should not exceed 3 meters. (Note: Longer lengths may not meet EN/IEC61000-6-3 requirements).
- If used in areas with frequent lightning strikes or unattended, install an external surge arrester.
- If an inverter is connected, connect it directly to the battery, not to the load side of the controller.
Step 3: Grounding
XTRA-N G3/XTRA-N G3 BLE series are common-negative controllers. All negative terminals can be grounded simultaneously, or any one can be grounded. The grounding terminal on the shell must be grounded to shield electromagnetic interference and prevent electric shock.
NOTICE:
- A common-negative controller is recommended for common-negative systems (e.g., motorhomes).
- Using a common-positive controller with a grounded positive electrode in a common-negative system may damage the controller.
Step 4: Connect Accessories
Remote Temperature Sensor Cable: Connect the remote temperature sensor cable to port 1 of the controller and place the other end close to the battery.

Figure: Remote Temperature Sensor (Model: RTS300R47K3.81A)
NOTICE:
If the remote temperature sensor is not connected, the controller will use a default battery charging/discharging temperature of 25°C without temperature compensation.
RS485 Communication Accessories: Refer to Subsection 5.1.3 Remote Setting for details on connecting RS485 communication accessories.
Step 5: Power On the Controller
Connect the battery's fast-acting fuse to power the controller. Check the battery indicator status (it should be lit green for normal operation). Then connect the fast-acting fuse and circuit breaker of the load and PV array. The system will then operate in preprogrammed mode.
NOTICE:
If the controller is not operating properly or the battery indicator shows an abnormality, refer to Section 7. Troubleshooting.
5. Operation
5.1 Interface Indicators and Buttons

Figure: Controller Indicators and Buttons
Indicator Status
| Indicator | Color | Status | Instruction |
|---|---|---|---|
| PV | Green | Solid ON | PV charges the battery with a low current |
| Green | Solid OFF | 1. No sunlight; 2. Connection error; 3. PV low voltage | |
| Green | Slowly flashing (1Hz) | Charging normally | |
| Green | Fast flashing (4Hz) | PV overvoltage | |
| BATT | Green | Solid ON | Normal |
| Green | Slowly flashing (1Hz) | Battery fully charged | |
| Green | Fast flashing (4Hz) | Battery overvoltage | |
| Orange | Solid ON | Battery undervoltage | |
| Red | Solid ON | Battery over-discharged | |
| LOAD | Yellow | Solid ON | Load on |
| Yellow | Solid OFF | Load off | |
| PV & BATT LED fast flashing | Controller overheating / System voltage error | ||
Button Functions
| Button | Action | Function |
|---|---|---|
| PV/+ | Press | PV browsing interface / Setting data + |
| Press & hold 5s | Set LCD cycle time, enable/disable communication port | |
| BATT/- | Press | BATT browsing interface / Cursor displacement during setting |
| Press & hold 5s | Set battery type, capacity, temperature unit | |
| LOAD/- | Press | Controller load browsing interface / Setting data |
| Press & hold 5s | Set load working mode | |
| SET | Press | Enter setting interface / Switch setting interface to browsing interface / Confirm setting parameter |
| ESC | Press | Exit setting interface |
5.2 Display Information
The LCD can be viewed clearly when the angle between the user's horizontal sight and the LCD is within 90°. If the angle exceeds 90°, the information may not be viewed clearly.
PV Information Display

Figure: PV Voltage/Current/Power/Generated Energy Display
Battery Information Display
Parameters in Primary mode (Voltage/Current/Temperature/SOC/BMS connection status) and Secondary mode (Voltage/Current/Temperature/Battery capacity level) are displayed.
Load Information Display
Displays Voltage/Current/Power/Consumed energy/Load working mode-Timer1/Load working mode-Timer2.
6. Controller Parameter Setting
6.1 Battery Parameters Settings
Supported Battery Types
| Category | Type |
|---|---|
| Battery | Sealed (default) |
| Gel | |
| Flooded | |
| Lithium battery | LiFePO4 (4S/8S/15S/16S) |
| Li(NiCoMn)O2 (3S/6S/7S/13S/14S) | |
| User | Customizable parameters |
NOTICE:
If the controller supports 48V system voltage, the battery type will display LiFePO4 F15/F16 and Li(NiCoMn)O2 N13/N14.
Local Setting of Battery Parameters
NOTICE:
When a default battery type is selected, battery voltage parameters cannot be modified. To change these, select the "USE" type.
Operation Steps:
- Enter the "USE" battery type: Press the BATT/- button to browse battery parameters, then press SET to enter the setting interface. Press BATT/- and hold for 5s to enter the battery-type interface. Use PV/+ or LOAD/- to select "USE" type, then press SET to confirm.
- Set battery parameters: Under the "USE" interface, parameters like System Voltage Level (SYS), Bulk Charging Voltage (BCV), Float Charging Voltage (FCV), Low Voltage Recovery Voltage (LVR), and Low Voltage Disconnect Voltage (LVD) can be set.
Remote Setting of Battery Parameters
To set battery parameters remotely, the communication mode needs to be set to Secondary mode.
1. By PC Software: Connect the controller's RJ45 interface to a PC's USB interface via a USB to RS485 cable. Set voltage parameters via the PC software when "USE" battery type is selected.

Figure: PC Software Connection
2. By APP (External WiFi/Bluetooth Module or Built-in Bluetooth): Connect the controller to an external WiFi module or Bluetooth module via the RS485 communication port, or use the built-in Bluetooth module (XTRA-N G3 BLE series). End-users can set voltage parameters via the APP after selecting the "USE" battery type. Refer to the cloud APP manual for details.

Figure: APP Connection via WiFi Module

Figure: APP Connection via Bluetooth Module
3. By MT52 Remote Meter: Connect the controller to the MT52 remote meter through a standard network cable. Set voltage parameters via the MT52 after selecting the "USE" battery type. Refer to the MT52 manual for details.

Figure: MT52 Remote Meter Connection
6.2 Load Operation Mode
The load operation mode can be configured via LCD settings or RS485 communication.
LCD Setting
When the LCD shows the load interface, use the LOAD/- button to browse load parameters, then SET to enter the setting interface. Press LOAD/- and hold for 5s to enter the load type interface. Use PV/+ or LOAD/- to change the load type, then SET to confirm.
| Code | Timer 1 (Mode) | Code | Timer 2 (Mode) |
|---|---|---|---|
| 100 | Light ON/OFF | 2n | Disabled |
| 101 | Load ON for 1 hour after sunset | 201 | Load ON for 1 hour before sunrise |
| 102 | Load ON for 2 hours after sunset | 202 | Load ON for 2 hours before sunrise |
| 103-113 | Load ON for 3-13 hours after sunset | 203-213 | Load ON for 3-13 hours before sunrise |
| 114 | Load ON for 14 hours after sunset | 214 | Load ON for 14 hours before sunrise |
| 115 | Load ON for 15 hours after sunset | 215 | Load ON for 15 hours before sunrise |
| 116 | Test mode | 2n | Disabled |
| 117 | Manual mode (Default load ON) | ||
| 118 | Always ON mode (24-hour power supply) | 2n | Disabled |
Note: When selecting Light ON/OFF, Test mode, or Manual mode, only Timer 1 can be set, and Timer 2 is disabled and displays "2n".
RS485 Communication Setting
1. Load Mode: Manual Control (default). Control load ON/OFF via button or remote commands (PC software, APP, remote meter).

Figure: Load Control Modes
2. Time Control: Control load ON/OFF time by setting the real-time clock.
3. Load Mode Settings: Set load modes via PC software, APP, or remote meter (MT52). Refer to Subsection 6.1.3 Remote Setting for connection diagrams and settings.
7. Protection Features
The EPEVER XTRA series controllers incorporate extensive electronic protections to ensure system safety and longevity.
| Protection | Description |
|---|---|
| PV Overcurrent/Overpower | If PV array current/power exceeds rated values, the controller charges at rated current/power. Note: PV open-circuit voltage should not exceed max PV open-circuit voltage to prevent damage. |
| PV Short Circuit | Controller is not damaged by short-circuiting in PV array when not charging. Do not short-circuit PV array during charging. |
| PV Reverse Polarity | Controller is not damaged if PV array polarity is reversed; it operates normally after correction. Note: Controller is damaged if PV array is connected reversely and actual operating power exceeds 1.5 times rated charging power. |
| Night Reverse Charging | Prevents battery discharge to the PV module at night. |
| Battery Reverse Polarity | Battery can be reversely connected when PV is disconnected. Correct wiring to resume. Note: Controller is damaged if PV connection is correct and battery connection is reversed. |
| Battery Overvoltage | Controller stops charging when battery voltage exceeds Overvoltage Disconnect Voltage to prevent overcharging. |
| Battery Over-discharge | Controller stops battery discharging when voltage is lower than Low Voltage Disconnect Voltage. |
| Battery Over-heating | Controller stops working if battery temperature (from external sensor) exceeds 65°C and resumes below 55°C. |
| Lithium Battery Low Temperature | Controller stops charging/discharging if battery temperature (from optional sensor) is below Low Temperature Protection Threshold (LTPT). Resumes when temperature is above LTPT. |
| Load Short Circuit | Controller automatically cuts off output if load is short-circuited (current ≥ 4 times rated load current). After 5 reconnect attempts, manual reset or waiting one night-day cycle is required. |
| Overload | Controller automatically cuts off output if load is overloading (current ≥ 1.02 times rated load current). After 5 reconnect attempts, manual reset or waiting one night-day cycle is required. |
| Controller Over-heating | Controller stops working if internal temperature exceeds 85°C and resumes below 75°C. |
| TVS High Voltage Transients | Internal TVS protects against high-voltage surge pulses. For areas with frequent lightning, an external surge arrester is recommended. |
7.1 Reduced Charging Power Mode
When the internal temperature reaches 81°C, the controller enters reduced charging power mode, reducing power by 5%, 10%, 20%, and 40% with every 1°C increase. If the internal temperature exceeds 85°C, charging stops. Charging resumes when the temperature declines below 75°C.

Figure: Reduced Charging Power Mode
8. Troubleshooting
Refer to the table below for common issues and their solutions.
| Possible Reasons | Faults | Troubleshooting |
|---|---|---|
| PV array disconnection | Charging LED indicator off during daytime when sunshine falls on PV modules properly. | Confirm that PV wire connections are correct and tight. |
| Battery voltage is lower than 8V | The wire connection is correct, and the controller is not working. | Please check the battery voltage. At least 8V to activate the controller. |
| Battery overvoltage | Green charging indicator fast flashes. Battery level shows full, battery frame and fault icon blink. | Check if the battery voltage is higher than OVD (overvoltage disconnect voltage), and disconnect the PV. |
| Battery over-discharged | Red charging indicator is ON solid. Battery level shows empty, battery frame and fault icon blink. | When the battery voltage is restored to or above LVR (low voltage reconnect voltage), the load will recover. |
| Battery Overheating | Red battery indicator slow flashes. Battery frame and fault icon blink. | The controller will automatically turn the system off. When the temperature declines to below 55°C, the controller will resume. |
| Controller Overheating | When the heat sink of the controller exceeds 85°C, the controller will automatically cut off the input and output circuit. When the temperature is below 75°C, the controller will resume work. | |
| System voltage error | PV and BATT indicators fast flash. | 1. Check whether the battery voltage matches the system voltage level set on the controller. 2. Change a matched battery or modify the system voltage level. Note: The fault can be ignored for no-battery applications if the system voltage level matches the actual system voltage. The alarm will disappear after 3 minutes or pressing the Load button to cancel it. |
| Load Short Circuit | 1. The load has no output. 2. LCD blinks "E001." 3. Load and fault icons blink. | 1. Check carefully load connection, and cancel the fault. 2. Restart the controller. 3. Wait for one night-day cycle (night time > 3 hours). |
| Load Overload | 1. The load has no output. 2. LCD blinks "E002." 3. Load and fault icons blink. | 1. Please reduce the number of electric equipment. 2. Restart the controller. 3. Wait for one night-day cycle (night time > 3 hours). |
9. Maintenance
The following inspections and maintenance tasks are recommended at least twice yearly for best performance.
DANGER:
Electric shock hazard! Ensure all power is turned off before performing any inspections or operations.
- Ensure the controller is firmly installed in a clean and dry environment.
- Ensure no obstructions to airflow around the controller. Clean any dirt or fragments from the heat sink.
- Check all exposed wires for insulation damage (sun exposure, frictional wear, dryness, insects, rats). Repair or replace damaged wires.
- Tighten all terminals. Inspect for loose, broken, or burnt wire connections.
- Check and confirm that LED indicators are consistent with requirements. Address any troubleshooting or error indications.
- Confirm all system components are tightly and correctly grounded.
- Confirm all terminals have no corrosion, insulation damage, high temperature, or burnt/discolored signs. Tighten terminal screws to the suggested torque.
- Clear dirt, nesting insects, and corrosion in time.
- Check and confirm that the lightning arrester is in good condition. Replace if necessary to avoid damaging the controller and other equipment.
10. Technical Specifications
Detailed specifications for various models are provided below. Note that when a lithium battery is used, the system voltage cannot be identified automatically, and the temperature compensation coefficient must be "0" and cannot be changed.

Figure: Technical Specifications (Part 1)

Figure: Technical Specifications (Part 2)

Figure: Technical Specifications (Part 3)
10.1 Conversion Efficiency Curves
The following graphs illustrate the conversion efficiency for various models under different solar module MPP voltages and nominal system voltages.

Figure: Conversion Efficiency Curves (Example for XTRA1206N G3/BLE)
11. User Tips
No specific user tips are available from provided reviews or Q&A content.
12. Warranty and Support
12.1 Disclaimers (Warranty Limitations)
The warranty does not apply to the following conditions:
- Damage caused by improper use or inappropriate environment (e.g., humid, high salt spray, corrosion, greasy, flammable, explosive, dust accumulative, or other severe environments).
- Actual current/voltage/power exceeding the controller's limit value.
- Damage caused by working temperature exceeding the rated range.
- Arc, fire, explosion, and other accidents caused by failure to follow controller stickers or manual instructions.
- Unauthorized dismantling or attempted repair.
- Damage caused by force majeure.
- Damage occurred during transportation or handling.
12.2 Contact Information
For technical support or inquiries, please contact:
HUIZHOU EPEVER TECHNOLOGY CO., LTD.Phone: +86-752-3889706
Email: info@epever.com
Website: www.epever.com