1. Important Safety Instructions
Please keep this manual for future reference. This manual contains the safety, installation, and operation instructions for the Tracer-AN G3 series MPPT solar charge controller (hereinafter referred to as "the controller").
- Read all the instructions and warnings carefully in the manual before installation.
- No user-serviceable components inside the controller. Do not disassemble or attempt to repair the controller.
- Mount the controller indoors. Avoid exposure to the components and do not allow water to enter the controller.
- Install the controller in a well-ventilated place. The controller's heat sink may become hot during operation.
- It is suggested to install appropriate external fast-acting fuses/breakers.
- Disconnect PV array connections and the battery's fast-acting fuse/breakers before controller installation and adjustment.
- Power connections must remain tight to avoid excessive heating from a loose connection.
NOTICE: Do not install the controller in humid, high salt spray, corrosion, greasy, flammable, explosive, dust accumulative, or other severe environments.
2. Product Overview
The Tracer-AN G3 series controllers adopt an advanced MPPT control algorithm to maximize energy harvest from your solar array. They feature high tracking efficiency, support multiple battery types, and include comprehensive electronic protections.
2.1 Controller Components

1. LCD Display, 2. SELECT button, 3. ENTER button, 4. Remote Temp. Sensor port, 5. Solar Panel Terminal, 6. Battery Terminal, 7. Load Terminal, 8. RJ45 Communication Port, 9. Mounting holes.
2.2 Key Features
- Advanced MPPT technology with tracking efficiency higher than 99.5%.
- Accurate recognition and tracking of multi-peaks maximum power point.
- Maximum DC/DC conversion efficiency of 98%.
- Support for multiple battery types, including lithium batteries.
- Equipped with a stable self-activation function for lithium batteries.
- Battery temperature compensation.
- Charging power and current limits to prevent overcharging.
- Real-time energy statistics function.
- RS485 communication interface for remote monitoring (optional 4G or Wi-Fi modules).
- Comprehensive electronic protections.
3. Setup and Installation
3.1 Installation Precautions
- Ensure the installation environment is not humid, corrosive, or dusty.
- Wear eye protection when installing open-type lead-acid batteries.
- Keep batteries away from metal objects to prevent short circuits.
- Ensure adequate ventilation as acid gas may be generated during charging.
- Avoid direct sunlight and rain infiltration if installing outdoors.
- Ensure all power connectors are tight and wires are secure to prevent overheating.
- Only charge lead-acid and lithium-ion batteries within the controller's specified range.
- Select system cables according to 5A/mm² or less current density.
- Grounding wire size should be at least 4mm².
- Tighten wiring screws to at least 1.2 N-m.
3.2 Mounting the Controller
The controller requires at least 150mm of clearance above and below for proper airflow. Ventilation is highly recommended if mounted in an enclosure.

Ensure 150mm clearance on top and bottom for optimal heat dissipation. Mounting holes are Φ5mm.
3.3 Wiring Connections
Connect the system in the order of Battery > Load > PV Array. Disconnect in the reverse order.

Illustrates the connection of solar panels, charge controller, battery, and loads in a household setup.

Connect solar panel, battery, and load wires to their respective terminals. Ensure correct polarity.
NOTICE: Do not connect the circuit breaker or fast-acting fuse during wiring. Ensure correct polarity. A fast-acting fuse (1.25 to 2 times the controller's rated current) must be installed on the battery side, no more than 150mm from the battery. The cable length of the battery should not exceed 3 meters. The recommended cable length of the PV array should not exceed 3 meters.
Wire Size Recommendations
| Connection | Wire Size (Tracer4210AN G3) | Circuit Breaker |
|---|---|---|
| PV Input | 16mm²/6AWG | 63A/125V/2 P |
| Battery | 16mm²/6AWG | 63A/125V/2 P |
| Load | 16mm²/6AWG | 63A/125V/2 P |
3.4 Grounding
Tracer-AN G3 series are common-negative controllers. The negative terminals of the PV array, battery, and load can be grounded simultaneously, or any negative terminal can be grounded. The grounding terminal on the controller's shell must be grounded to shield electromagnetic interference and prevent electric shock.
3.5 Connecting Accessories
- Temperature Sensor: Connect the included temperature sensor to the designated port. If not connected or damaged, the controller will use a default temperature of 25°C for charging/discharging.
- RS485 Communication: Connect RS485 communication cables for remote monitoring. An RS485 communication isolator is recommended.
3.6 Power On
Connect the battery fast-acting fuse to power the controller. Check the battery indicator status (should be lit green). Then connect the fast-acting fuse and circuit breaker of the load and PV array. The system will now operate in preprogrammed mode.
4. Operating Instructions
4.1 LCD Display and Buttons
The LCD displays system status, parameters, and error codes. Use the SELECT and ENTER buttons to navigate and set parameters.
| Mode | Action |
|---|---|
| Load ON/OFF | Press ENTER button in manual load mode. |
| Clear fault | Press ENTER button. |
| Browsing mode | Press SELECT button to cycle through interfaces. |
| Setting mode | Press and hold ENTER for 5s. Use SELECT to set, ENTER to confirm. |
4.2 Battery Charging Stages
The controller utilizes a three-stage battery charging algorithm to prolong battery lifespan.

Illustrates Bulk Charging, Constant Charging (Boost/Equalize), and Float Charging phases.
- Bulk Charging: Controller operates in constant current mode, delivering maximum current until battery voltage reaches the constant voltage set point.
- Constant Charging: MPPT charging stops, and current gradually drops. Includes Equalize Charging (on the 28th of each month) and Boost Charging (default 2 hours).
- Float Charging: Battery voltage is reduced to a preset float voltage, maintaining a fully charged state with weak charging.
4.3 Setting Parameters
Parameters like battery type, load modes, and voltage settings can be adjusted via the LCD, PC software, APP, or remote meter (MT52).
- Battery Type: Supports Sealed (default), Gel, FLD, LiFePO4, Li(NiCoMn)O2, and User-defined types.
- Load Modes: Multiple load control modes are available: Manual, Dusk to Dawn with Timer, Timer, and Dust to Dawn.

Details various load control options and the comprehensive protection features of the controller.
5. Maintenance
Regular maintenance ensures optimal performance and longevity of your controller. Perform these tasks at least twice yearly:
- Ensure no obstructions block airflow around the controller. Clean any dirt or debris from the radiator.
- Inspect all wires for insulation damage (sun exposure, wear, pests). Repair or replace as needed.
- Verify LCD indicator display matches actual operation. Address any troubleshooting or error conditions.
- Confirm terminals have no corrosion, insulation damage, high temperature signs, or discoloration. Tighten terminal screws to the suggested torque.
- Clean dirt, nesting insects, and corrosion promptly.
- Check the lightning arrester (if installed) for good condition and replace if necessary.
DANGER: Electric shock hazard! Ensure power is turned off before performing any maintenance operations.
6. Troubleshooting
Refer to the table below for common issues and their solutions.
| Fault | Symptoms | Troubleshooting |
|---|---|---|
| PV array open-circuit | Plenty of sunlight, but LCD shows no PV input. | Confirm PV array connections are correct and tight. |
| Battery voltage lower than 8V | Controller not working despite correct wiring. | Check battery voltage (needs at least 8V to activate controller). |
| Battery overvoltage | Battery frame blink, fault icon blink. | Check if battery voltage is higher than OVD; disconnect PV array. |
| Battery over-discharged | Battery frame blink, fault icon blink. | Recharge battery; load will recover when voltage is above LVR. |
| Battery overheating | Battery frame blink, fault icon blink. | Ensure proper ventilation; controller resumes below 55°C. |
| Overload | Load off, load and fault icon blink. | Reduce number of electric devices; restart controller or clear faults. |
| Load short-circuit | Load off, load and fault icon blink. | Check load connections; clear fault; restart controller or clear faults. |
7. Technical Specifications
7.1 Electrical Parameters (Tracer4210AN G3)
| Parameter | Value |
|---|---|
| Battery Rated Voltage | 12/24VDC Auto-recognition |
| Rated Charging Current | 40A |
| Rated Discharge Current | 40A |
| Controller Work Voltage Range | 8-31V |
| PV Max. Open-circuit Voltage | 100V (at min. operating temp), 92V (at 25°C) |
| MPPT Voltage Range | (Battery voltage + 2V) to 72V |
| Rated Charging Power | 520W/12V, 1040W/24V |
| Static Losses | ≤ 8mA (12V), ≤ 5mA (24V) |
| Discharge-circuit Voltage Drop | ≤ 0.23V |
| Temperature Compensation | -3mV/°C/2V (Default) |
| Grounding Type | Common negative |
| RS485 Port | 5VDC/200mA (RJ45) |
7.2 Environmental Parameters
| Parameter | Value |
|---|---|
| Work Temperature Range | -25°C to +45°C (100% loads working) |
| Storage Temperature Range | -20°C to +70°C |
| Relative Humidity | < 95% (N.C.) |
| Enclosure | IP30 |
7.3 Mechanical Parameters (Tracer4210AN G3)
| Parameter | Value |
|---|---|
| Dimension (L × W × H) | 252mm × 180mm × 63mm |
| Mounting Size (L × W) | 204mm × 171mm |
| Mounting Hole Size | Φ5mm |
| Terminal | 6AWG (16mm²) |
| Recommended Wire Size | 6AWG (16mm²) |
| Net Weight | 1.65kg |
8. User Tips
- Always ensure proper ventilation around the controller to prevent overheating, especially during high load operation.
- Double-check all wiring connections for polarity and tightness before powering on the system to avoid damage.
- For optimal performance, keep battery cables as short as possible and use the recommended wire gauges.
- Regularly monitor the LCD display for system status and any error codes to address issues promptly.
9. Warranty and Support
For detailed warranty information, please refer to the official EPEVER warranty policy provided with your product or visit the manufacturer's website. Keep your purchase receipt as proof of purchase.
For further assistance, technical support, or to download the latest version of the user manual, please visit the EPEVER official website or contact their customer service.
Additional Resources: A PDF version of this user manual may be available for download from the manufacturer's website: EPEVER Tracer-AN G3 User Manual (PDF)
Copyright © EPEVER. All rights reserved.