1. Overview
Thank you for selecting the ViewStar AU series common positive solar charge controller. The VS-AU controller is a PWM charge controller with built-in LCD display that adopts the most advanced digital technique. The multiple load control modes enable it can be widely used on solar home system, traffic signal, solar street light, solar garden lamp, etc.
The VS-AU series is designed for solar energy systems where the gap between solar panel working voltage and battery voltage is not significant, offering a reliable and cost-effective solution. It is widely applied in rural electrification and home power systems.

2. Product Features
- Adopt high quality components of ST, IR and Infineon, ensuring product lifespan.
- Terminals have UL and VDE certification, enhancing product safety and reliability.
- Controller can work continuously at full load within the environment temperature range from -25°C to 55°C.
- 3-Stage intelligent PWM charging: Bulk, Boost/Equalize, Float.
- Support 3 charging options: Sealed, Gel, and Flooded batteries.
- LCD display design, dynamically displaying device's operating data and working condition.
- Double USB design, providing power supply charge for electronic equipment (5VDC/2.4A total output).
- Humanized button settings for comfortable and convenient operation.
- Multiple load control modes.
- Energy statistics function.
- Battery temperature compensation function.
- Extensive Electronic protection.



3. Wiring
Connect components to the charge controller in the sequence as shown in the diagram below and pay much attention to the "+" and "-" polarities. Please do not insert the fuse or turn on the breaker during the installation. When disconnecting the system, the order should be reversed.
After powering on the controller, check the LCD. If it does not display, refer to chapter 6 (Troubleshooting). Always connect the battery first, in order to allow the controller to recognize the system voltage.
The battery fuse should be installed as close to the battery as possible. The suggested distance is within 150mm.
The VS-AU series is a positive ground controller. Any positive connection of solar, load or battery can be earth grounded as required.
NOTE: Please connect the inverter or other load that has a large start current to the battery rather than to the controller, if the inverter or other load is necessary.

Optional Accessory: Remote Temperature Sensor (RTS)
Name: Remote Temperature Sensor
Model: RTS300R47K3.81A
Acquisition of battery temperature for undertaking temperature compensation of control parameters. The standard length of the cable is 3m (length can be customized). The RTS300R47K3.81A connects to port ③ on the controller.
NOTE: Unplug the RTS, the temperature of battery will be set to a fixed value 25°C.
4. Operation
4.1 Button Function
| Button | Function |
|---|---|
| MENU button | Browse interface Setting parameter |
| SET button | Load ON/OFF Clear error Enter into Set Mode Save data |
4.2 LCD Display

Status Description
| Item | Icon | Status |
|---|---|---|
| Day | ||
| Night | ||
| PV array | No charging | |
| Charging | ||
| PV | PV Voltage, Current, Power | |
| Battery capacity, in Charging | ||
| Battery | BATT. | Battery voltage, current, temperature |
| BATT. TYPE | Battery type | |
| Load | Load ON | |
| Load OFF | ||
| LOAD | Load Voltage, Current, Load mode |
Browse Interface
When there is no operation, the interface will automatically cycle through different displays. The following two interfaces will not be displayed during automatic cycle:
- Load Type: Displays the current load mode.
- Accumulative Power: Displays total energy generated.
Accumulative power zero clearing: Under PV power interface, press SET button and hold for 5s then the value will blink. Press SET button again to clear the value.
Setting temperature unit: Under battery temperature interface, press SET button and hold for 5s to switch between °C and °F.
4.3 Load Mode Setting
Operating Steps: Under load mode setting interface, press SET button and hold for 5s until the number begins flashing. Then press MENU button to set the parameter, press SET button again to confirm.
| Mode | Timer 1 | Mode | Timer 2 |
|---|---|---|---|
| Light ON/OFF | Disabled | ||
| Load will be on for 1 hour since sunset | Load will be on for 1 hour before sunrise | ||
| Load will be on for 2 hours since sunset | Load will be on for 2 hours before sunrise | ||
| Load will be on for 3-13 hours since sunset | Load will be on for 3-13 hours before sunrise | ||
| Load will be on for 14 hours since sunset | Load will be on for 14 hours before sunrise | ||
| Load will be on for 15 hours since sunset | Load will be on for 15 hours before sunrise | ||
| Test mode | Disabled | ||
| Manual mode (Default load ON) | Disabled |
NOTE: Please set Light ON/OFF, Test mode and Manual mode via Timer1. Timer2 will be disabled and display "2 n".
4.4 Battery Type
Operating Steps: Under Battery Voltage interface, press SET button and hold for 5s then enter into the interface of Battery type setting. After choosing the battery type by pressing MENU button, waiting for 5s or pressing SET button again to modify successfully.

NOTE: Please refer to the battery voltage parameters table for the different battery types in the Specifications section.
Maintenance
The EPEVER VS-AU series solar charge controller is designed for durability and requires minimal maintenance. However, to ensure optimal performance and longevity, consider the following:
- Regular Inspection: Periodically check all wiring connections to ensure they are secure and free from corrosion.
- Cleanliness: Keep the controller clean and free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquids or solvents.
- Ventilation: Ensure that the controller's ventilation openings are not obstructed to allow for proper heat dissipation.
- Environmental Conditions: Operate the controller within its specified temperature and humidity ranges. Avoid exposure to direct sunlight, rain, or excessive moisture.
6. Troubleshooting
| Faults | Possible reasons | Troubleshooting |
|---|---|---|
| The LCD is off during daytime when sunshine falls on PV modules properly | PV array disconnection | Confirm that PV wire connections are correct and tight. |
| Wire connection is correct, LCD not display | 1) Battery voltage is lower than 9V 2) PV voltage is less than battery voltage | 1) Please check the voltage of battery. At least 9V voltage to activate the controller. 2) Check the PV input voltage which should be higher than battery's. |
| Interface blink: Battery over voltage | Battery over voltage | Check if the battery voltage is higher than OVD point (over voltage disconnect voltage), and disconnect the PV. |
| Interface blink: Battery over discharged | Battery over discharged | When the battery voltage is restored to or above LVR point (low voltage reconnect voltage), the load will recover. |
| Interface blink: Battery Overheating | Battery Overheating | The controller will automatically turn the system off. But while the temperature decline to be below 50°C, the controller will resume. |
| Interface blink: Over load or Short circuit | Over load or Short circuit | Please reduce the number of electric equipment or check carefully loads connection. |
5. Protections
| Protection | Conditions | Status |
|---|---|---|
| PV Reverse Polarity | When the battery is correct connecting, the PV can be reversed. | The controller is not damaged |
| Battery Reverse Polarity | When the PV is not connecting, the battery can be reversed. | |
| Battery Over Voltage | The battery voltage reaches to the OVD | Stop charging |
| Battery Over Discharge | The battery voltage reaches to the LVD | Stop discharging |
| Battery Overheating | Temperature sensor is higher than 65°C Temperature sensor is less than 55°C | Output is OFF Output is ON |
| Load failure | Load overload / Load short circuit | When load current reaches 1.02-1.05 times, 1.05-1.25 times, 1.25-1.35 times and 1.35-1.5 times more than nominal value, controller will automatically turn off loads in 50s, 30s, 10s and 2s respectively. |
7. Technical Specifications
| Item | VS1024AU | VS2024AU | VS3024AU | VS4524AU | VS6024AU |
|---|---|---|---|---|---|
| Nominal system voltage | 12/24VDC Auto | ||||
| Battery input voltage range | 9V ~ 32V | ||||
| Rated charge current | 10A@55°C | 20A@55°C | 30A@55°C | 45A@55°C | 60A@55°C |
| Rated discharge current | 10A | 20A | 30A | 45A | 60A |
| Max. PV open circuit voltage | 50V | ||||
| Battery type | Sealed (Default) / Gel / Flooded | ||||
| Equalize Charging Voltage | Sealed:14.6V / Gel: No / Flooded:14.8V | ||||
| Boost Charging Voltage | Sealed:14.4V / Gel:14.2V / Flooded:14.6V | ||||
| Float Charging Voltage | Sealed/Gel/Flooded:13.8V | ||||
| Low Voltage Reconnect Voltage | Sealed/Gel/Flooded:12.6V | ||||
| Low Voltage Disconnect Voltage | Sealed/Gel/Flooded:11.1V | ||||
| Self-consumption | ≤9.2mA/12V; ≤11.7mA/24V | ||||
| USB output | 5VDC/2.4A (Total) | ||||
| Temperature compensation coefficient | -3mV/°C/2V (25°C) | ||||
| Charge circuit voltage drop | ≤0.29V | ||||
| Discharge circuit voltage drop | ≤0.16V | ||||
| LCD temperature range | -20°C ~ +70°C | ||||
| Working environment temperature | -25°C ~ +55°C (Product can work continuously at full load) | ||||
| Relative humidity | ≤95%, N.C. | ||||
| Enclosure | IP30 | ||||
| Grounding | Common Positive | ||||
| Overall dimension (LxWxH)(mm) | 142x85x41.5 | 160x94.9x49.3 | 181x100.9x59.8 | 194x118.4x63.8 | 214x128.7x72.2 |
| Mounting dimension | 130x60mm | 148x70mm | 172x80mm | 185x90mm | 205x100mm |
| Mounting hole size | Φ4.5mm | ||||
| Terminals | 4mm²/12AWG | 10mm²/8AWG | 16mm²/6AWG | 16mm²/6AWG | 25mm²/4AWG |
| Net weight | 0.22kg | 0.35kg | 0.55kg | 0.76kg | 1.02kg |
Note: Above parameters are in 12V system at 25°C, twice in 24V system, triple in 36V system and quadruple in 48V system.

User Tips
No specific user tips were available from buyer reviews or Q&A content for this product. Always refer to the manual for detailed instructions and safety guidelines.
Warranty & Support
8. Disclaimer
This warranty does not apply under the following conditions:
- Damage from improper use or use in an unsuitable environment.
- PV or load current, voltage or power exceeding the rated value of controller.
- The controller's working temperature exceeds the limit working environment temperature.
- User disassembly or attempted repair of the controller without permission.
- The controller is damaged due to natural elements such as lightning.
- The controller is damaged during transportation and shipment.
Certifications
The EPEVER VS-AU series solar charge controller is certified with:
- CE
- FCC
- RoHS
- IEC
- EMC
- UL (where applicable)