EPEVER Tracer2606BP

Contents

EPEVER Tracer2606BP MPPT Solar Charge Controller User Manual

Model: Tracer2606BP

1. Overview

The EPEVER Tracer2606BP MPPT Solar Charge Controller is an advanced device designed to optimize solar power systems. It utilizes Maximum Power Point Tracking (MPPT) technology to significantly increase charging efficiency compared to traditional PWM charge controllers. This controller supports various battery types, including lead-acid (sealed, gel, flooded) and lithium batteries, and offers a lithium battery self-activating function and low-temperature protection.

Key features include:

  • MPPT (Maximum Power Point Tracking) charging for up to 30% efficiency increase.
  • Support for lead-acid and lithium-ion batteries.
  • Lithium battery self-activating function and low-temperature protection.
  • Multi-load control mode.
  • Extensive electronic protections.
  • RS485 communication, support for IoT monitoring and remote control via app or cloud platform.
  • IP68 ingress protection.
  • Aluminum housing for efficient cooling.
  • Real-time energy statistics function.
Overview of EPEVER Tracer-BP series MPPT solar charge controller features and applications
Figure 1: Overview of Tracer-BP series features and typical applications including solar cars, homes, backpacks, boats, street lights, and power generators.

2. Safety Information

Please read all instructions carefully before installation and operation. Failure to follow these safety guidelines may result in damage to the product, personal injury, or property damage.

  • Do NOT disassemble or attempt to repair the controller.
  • Install external fast-acting fuses or breakers as required.
  • Disconnect the solar module and fast-acting fuse/breakers near the battery before installing or moving the controller.
  • Ensure power connections are tight to avoid excessive heating from loose connections.
  • Only batteries that comply with the controller's parameters can be charged.
  • Battery connections can be wired to a single battery or a bank of batteries.
  • Be aware of the risk of electric shock; the PV and load may produce high voltages when the controller is running.
  • Do not install this product in humid, salt spray, corrosive, greasy, flammable, explosive, dust accumulative, or other severe environments.

3. Product Components and Features

The Tracer2606BP controller features a compact design with clearly labeled terminals and indicators. The device is designed for robust performance with an IP68 waterproof rating.

EPEVER Tracer2606BP MPPT Solar Charge Controller with WIFI module, showing 12/24VDC battery rated voltage and 10A rated charge current.
Figure 2: EPEVER Tracer2606BP MPPT Solar Charge Controller with WIFI module, indicating 12/24VDC battery rated voltage and 10A rated charge current.
Back view of Tracer2606BP controller showing model, voltage, current, max PV input power, and SW version.
Figure 3: Back view of the Tracer2606BP controller, displaying model information, voltage, current, maximum PV input power, and software version.

Component Identification:

Refer to the diagram below for component identification:

Detailed diagram of Tracer-BP controller components including terminals, LEDs, and optional accessories.
Figure 4: Detailed diagram of Tracer-BP controller components, including terminal connections, LED indicators, and optional accessories like WIFI and Bluetooth modules.
  1. Temperature Sensor
  2. PV Positive and Negative Wires
  3. Battery Positive and Negative Wires
  4. Load Positive and Negative Wires
  5. Charging Status LED indicator
  6. Battery Status LED indicator
  7. RS485 waterproof port
  8. Waterproof cap (Included)

Note: If the temperature sensor is short-circuited or damaged, the controller will charge/discharge at a default temperature of 25°C. The RS485 port provides a DC power supply of 5VDC/150mA and has short-circuit protection. When the RS485 communication port is not in use, ensure the waterproof cap is installed to prevent water ingress.

4. Setup and Installation

4.1. Wiring Connection Sequence

Connect components to the controller in the following sequence: Solar Panel (PV) → Battery (BATT) → Load (LOAD). Pay close attention to the positive (+) and negative (-) terminals. Do not insert the fast-acting fuse or turn on the breaker during installation. When disconnecting the system, reverse the order.

Wiring diagram for EPEVER Tracer2606BP showing connections for PV, Battery, and Load.
Figure 5: Wiring diagram for the Tracer2606BP controller, illustrating the connection order for solar panels, battery, and load.

4.2. Initial Power-Up

  1. After powering the controller, the battery LED indicator on the controller should flash green. If it does not, refer to the Troubleshooting section.
  2. Connect a fast-acting fuse in series through the battery positive (+) in the circuit. The battery fast-acting fuse must be 1.25 to 2 times the rated current. The installed distance is within 150mm.

4.3. Optional Accessories Connection

The controller supports various optional accessories for enhanced functionality, such as WIFI and Bluetooth modules for remote monitoring and control.

Diagrams for connecting WIFI and Bluetooth modules to the EPEVER Tracer-BP controller.
Figure 6: Connection diagrams for optional WIFI and Bluetooth modules, and communication cables (CC-4M/5M/RJ45-3.81-A, CC-RS485-RS485-150U-3LLT).

For detailed instructions on connecting and using EPEVER Cloud services and mobile apps, refer to the Solar Guardian user manual. Note that MT52 and eLOG01-G3 accessories are not waterproof and require proper protection if used outdoors.

5. Operating Instructions

5.1. LED Indicators

The controller uses LED indicators to display its operational status. Understanding these indicators is crucial for monitoring the system.

Indicator Color Status Instruction
PV Green On Solid PV connection normal but low voltage (irradiance) from PV, no charging
Green OFF No PV voltage (night time) or PV connection problem
Green Slowly Flashing (1Hz) In charging
BATT Green Fast Flashing (4Hz) PV overvoltage
Green On Solid Battery is normal
Green Slowly Flashing (1Hz) Battery charges full
Orange On Solid Battery under voltage
Red Fast Flashing (4Hz) Battery overheating / Lithium battery low temperature
Charging indicator (green) and battery indicator (orange) flashing simultaneously System voltage error*

*When the battery type is a lithium battery, the controller does not recognize the system voltage automatically.

5.2. Load Working Mode

The controller supports various load working modes:

  1. Manual Mode (Default ON): The load is manually turned ON/OFF.
  2. Light ON/OFF: The load turns on when it detects darkness and turns off when it detects light.
    • Turn-On voltage (Adjustable): 5V (12V system), delay 10min.
    • Turn-Off voltage (Adjustable): 6V (12V system), delay 10min.
    • Note: For 24V systems, multiply voltage values by 2.
  3. Light ON + Timer: The load turns on when it detects darkness and stays on for a set duration.
  4. Real-time Control: Control the load ON/OFF time by setting a real-time clock.

Caution: In Light ON/OFF and Light ON+Timer modes, the Load is turned on after a 10-minute delay.

5.3. Load Self-Test Function

The load is automatically turned ON after powering on the controller for 10 seconds. After the load remains ON for 10 seconds, the controller restores to the set working mode.

6. Protection Functions

The Tracer2606BP controller includes extensive electronic protections to ensure system safety and longevity:

  • PV Over Current: The controller limits the battery charging current to the Maximum Battery Current rating. An oversized solar array will not operate at peak power.
  • PV Short Circuit: When PV short circuit occurs on low-power, the controller stops charging. Clear the short circuit to resume operation.

    WARNING: The controller may be damaged if the PV input experiences a short circuit on high-power.

  • PV Reverse Polarity: The PV can be reversely connected without damage if only the PV is connected to the controller, or if the battery is positively connected and the PV's open-circuit voltage is lower than 85V (for Tracer26/39/5210BP).

    WARNING: The controller will be damaged if the PV array has straight polarity and its actual operating power is 1.5 times greater than the rated charge power.

  • Battery Reverse Polarity: Complete protection against reverse battery polarity. Correct the wire connection to resume regular operation.

    WARNING: The controller will be damaged if the PV connection is correct, and the battery connection is reversed!

  • Battery Over Voltage: When the battery voltage reaches the Over Voltage Disconnect Voltage, the controller stops charging to protect the battery from overcharging.
  • Battery Over Discharge: When the battery voltage reaches the Low Voltage Disconnect Voltage, the controller stops discharging to protect the battery from over-discharging.
  • Battery Overheating: If the environment temperature exceeds 65°C, the controller automatically starts overheating protection, stopping work and recovering below 55°C.
  • Lithium Battery Low Temperature: If the temperature sensor detects a temperature below the low-temperature value, the lithium battery stops charging/discharging. It resumes when the temperature rises above the low-temperature value.
  • Load Overload: If the load current exceeds 1.05 times the maximum load current rating, the controller will disconnect the load. Overloading must be cleared by reducing the load and restarting the controller.
  • Load Short Circuit: The load will be switched off if a short circuit (2-4 times rated current) occurs. The controller will automatically attempt to reconnect the load 5 times. If the short circuit persists after 5 attempts, the user must clear the short circuit, restart the controller, or wait for one night-day cycle (night time > 3 hours).
  • Temperature Sensor Break Down: If the temperature sensor is short-circuited or damaged, the controller will charge/discharge at the default temperature of 25°C to prevent battery damage.
  • High Voltage Transients: The controller is protected against small high voltage transients. For lightning-prone areas, additional external suppression is recommended.

7. Troubleshooting

This section provides solutions for common issues encountered with the Tracer2606BP controller.

Faults Possible Reasons Troubleshooting
LED Charging indicator turns off during daytime when sunshine falls on PV modules properly PV array disconnection Confirm that PV and battery wire connections are correct and tight.
No LED indicator Battery voltage may be less than 8.5V Measure battery voltage with a multimeter. Minimum 8.5V can start up the controller.
Battery LED indicator green fast Flashing Battery over voltage Check if the battery voltage is higher than OVD, and disconnect the PV.
Battery LED indicator red Battery over-discharged When the battery voltage is restored to or above the LVR point (low voltage reconnect voltage), the load will recover.
Battery LED indicator red flashing Battery Overheating The controller will automatically turn the system off. But while the temperature decline to be below 50°C, the controller will resume.
Load is not output Load Overload ① Please reduce the number of electric equipment. ② Restart the controller. ③ Wait for one night-day cycle (night time > 3 hours).
Load Short Circuit ① Check carefully loads connection, clear the fault. ② Restart the controller. ③ Wait for one night-day cycle (night time > 3 hours).

Note: When overload or short circuit occurs, the load has a 5-time auto-recovery output function, with each time delay being 5s, 10s, 15s, 20s, 25s respectively.

8. Specifications

Detailed technical specifications for the Tracer2606BP controller:

Item Tracer2606BP Tracer3906BP Tracer5206BP Tracer2610BP Tracer3910BP Tracer5210BP Tracer7810BP
Nominal system voltage 12/24VDC Auto (Lithium battery cannot automatically identify system voltage)
Battery input voltage range 8.5 to 32VDC
Rated charge/discharge current 10A 15A 20A 10A 15A 20A 30A
Rated charge power 130W/12V; 260W/24V 200W/12V; 400W/24V 260W/12V; 520W/24V 130W/12V; 260W/24V 200W/12V; 400W/24V 260W/12V; 520W/24V 390W/12V; 780W/24V
Max. PV open circuit voltage 60V (at minimum operating environment temperature) / 92V (at 25°C environment temperature) 100V (at minimum operating environment temperature) / 46V (at 25°C environment temperature)
MPP Voltage range (Battery voltage+2V) to 72V (Battery voltage+2V) to 36V
Battery Type Lead-acid battery: Sealed (Default)/Gel/Flooded/User; Lithium battery: LiFePO4/Li-NiCoMn/User
Equalize Charging Voltage Sealed: 14.6V, Gel: No, Flooded: 14.8V, User: 9-17V (X2/24V)
Boost Charging Voltage Sealed: 14.4V, Gel: 14.2V, Flooded: 14.6V, User: 9-17V (X2/24V)
Float Charging Voltage Sealed/Gel/Flooded: 13.8V, User: 9-17V (X2/24V)
Low Voltage Reconnect Voltage Sealed/Gel/Flooded: 12.6V, User: 9-17V (X2/24V)
Low Voltage Disconnect Voltage Sealed/Gel/Flooded: 11.1V, User: 9-17V (X2/24V)
Lithium Battery Boost Charging Voltage LiFePO4: 14.5V, Li-NiCoMn: 12.5V, User: 9-17V (X2/24V)
Lithium Battery Low Voltage Reconnect Voltage LiFePO4: 12.8V, Li-NiCoMn: 10.5V, User: 9-17V (X2/24V)
Lithium Battery Low Voltage Disconnect Voltage LiFePO4: 11.1V, Li-NiCoMn: 9.3V, User: 9-17V (X2/24V)
Self-consumption ≤13mA/12V; ≤ 11.5mA/24V
Temperature compensation coefficient -3mV/°C/2V (Lithium battery don't have temperature compensation coefficient)
Communication RS485
Environment Temperature -40°C to +60°C
Enclosure IP68
Overall dimension 124×89×30mm 150×93.5×32.7mm 153×105×52.1mm 124×89×30mm 150×93.5×32.7mm 153×105×52.1mm 153.3×105×52.1mm
Mounting hole size Φ3.5mm
Mounting size 88×76mm 120×83mm 120×94mm 88×76mm 120×83mm 120×94mm 120×94mm
Power cable 14AWG (2.5mm²) 12AWG (4mm²) 12AWG (4mm²) 14AWG (2.5mm²) 12AWG (4mm²) 12AWG (4mm²) 10AWG (6mm²)
Net weight 0.54kg 0.74kg 1.20kg 0.54kg 0.74kg 1.20kg 1.26kg

Note: Specifications are subject to change without prior notice. Version number: V3.6

9. Warranty and Support

9.1. Disclaimer

The manufacturer is not liable for damages arising from:

  • Improper use or use in an unsuitable environment.
  • PV or load current, voltage, or power exceeding the rated value of the controller.
  • The controller's working temperature exceeding the limit working environment temperature.
  • User disassembly or attempted repair of the controller without permission.
  • Damage due to natural elements such as lightning.
  • Damage during transportation and shipment.

9.2. Additional Resources

For further information, including the full user manual in PDF format, please refer to the official EPEVER website or the provided PDF document: EPEVER Tracer-BP Series User Manual (PDF).

You can also access EPEVER cloud services and mobile applications for monitoring and setting parameters:

10. User Tips

No specific user tips were available from provided reviews or Q&A content.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.