1. Introduction and Overview

The EPEVER Tracer-AN G3/Tracer-AN G3 BLE series MPPT solar charge controllers are designed with advanced Maximum Power Point Tracking (MPPT) technology to optimize solar energy harvesting. These controllers feature a built-in Bluetooth module (for BLE series) for convenient parameter reading and writing via a phone app. They offer high efficiency, comprehensive electronic protections, and support various battery types, making them suitable for RVs, household systems, field monitoring, and other applications.

EPEVER Tracer4210AN G3 MPPT Solar Charge Controller with MT52 Remote Meter
Figure 1.1: EPEVER Tracer4210AN G3 MPPT Solar Charge Controller with MT52 Remote Meter.

Key Features:

  • High quality components for extended service life.
  • Advanced MPPT technology with tracking efficiency higher than 99.5%.
  • Accurate recognition and tracking of multi-peak maximum power points.
  • Wide Maximum Power Point (MPP) running voltage for optimized PV utilization.
  • Maximum DC/DC conversion efficiency of 98%.
  • Support for multiple battery types, including lithium batteries.
  • Stable self-activation function for lithium batteries.
  • Adjustable battery voltage parameters via LCD.
  • Battery temperature compensation.
  • Charging power and current limited to rated values.
  • Real-time energy statistics.
  • Automatic charging power reduction for over-temperature.
  • Built-in Bluetooth (BLE series) or optional external modules for APP settings.
  • RS485 communication interface with standard Modbus protocol.
  • Power protection chip for communication interface (5VDC/200mA, over-current, short-circuit protections).
  • Setting parameters via PC software, APP, or remote meter.
  • Constant voltage output function.
  • Comprehensive electronic protections.
  • Multiple load work modes.
  • Low self-consumption (less than 10mA).
  • Full load operation without charging power reduction in working temperature range.
High Efficiency of EPEVER MPPT Solar Charge Controller
Figure 1.2: High efficiency of the EPEVER MPPT Solar Charge Controller, demonstrating 99.5% MPPT tracking efficiency and 98% charging conversion efficiency.
EPEVER MPPT Solar Charge Controller compatible with various battery types
Figure 1.3: The controller supports various battery types including Gel, Sealed, Lithium, and Lead-acid batteries.

2. Important Safety Instructions

Please reserve this manual for future review. This manual contains safety, installation, and operation instructions for the Tracer-AN G3/Tracer-AN G3 BLE series MPPT solar controller.

  • Read all instructions and warnings carefully before installation.
  • No user-serviceable components inside; do not disassemble or attempt repair.
  • Mount indoors, avoid exposure to components and water.
  • Install in a well-ventilated place; heat sink may become hot.
  • Install appropriate external fast-acting fuses/breakers.
  • Disconnect PV array and battery fuses/breakers before installation/adjustment.
  • Ensure tight power connections to prevent excessive heating.

WARNING:

Do not install the controller in humid, high salt spray, corrosive, greasy, flammable, explosive, dust accumulative, or other severe environments.

3. Disclaimers

The warranty does not apply to the following conditions:

  • Damage caused by improper use or inappropriate environment (e.g., humid, high salt spray, corrosion, greasy, flammable, explosive, dust accumulative, or other severe environments).
  • Actual current/voltage/power exceeding the controller's limit value.
  • Damage caused by working temperature exceeding the rated range.
  • Arc, fire, explosion, and other accidents caused by failure to follow controller stickers or manual instructions.
  • Unauthorized dismantling or attempted repair.
  • Damage caused by force majeure.
  • Damage occurred during transportation or handling.

4. Product Characteristics

Product characteristics diagram of the EPEVER MPPT Solar Charge Controller
Figure 4.1: Product Characteristics and Components.
No.DescriptionNo.Description
1SELECT button6RS485 communication interface
2RTS Interface7Mounting Hole Φ5mm
3PV Terminals8ENTER button
4Battery terminals9LCD
5Load terminals

Note: If the remote temperature sensor is not connected or damaged, the controller will charge/discharge at a default temperature setting of 25°C (no temperature compensation).

5. Setup and Installation

5.1 Installation Attentions

  • Familiarize yourself with installation steps before proceeding.
  • Avoid installing in humid, high salt spray, corrosive, greasy, flammable, explosive, or dusty environments.
  • Exercise caution when installing batteries. Wear eye protection and rinse with clean water if battery acid contact occurs.
  • Keep batteries away from metal objects to prevent short circuits.
  • Ensure good ventilation in the surrounding environment, especially when charging, as acid gas may be generated.
  • Avoid direct sunlight and rain infiltration if installing outdoors.
  • Ensure tight power connections and secure cables with clamps to prevent high heat, melting insulation, or fire.
  • Only charge lead-acid and lithium-ion batteries within the controller's control range.
  • The battery connection can be made to a single battery or a bank of batteries.
  • Select system cables according to 5A/mm² or less current density.

5.2 Mounting the Controller

The controller requires at least 150mm of clearance above and below for proper airflow. Ventilation is highly recommended if mounted in an enclosure.

Mounting diagram for the EPEVER MPPT Solar Charge Controller
Figure 5.1: Recommended mounting clearances for the controller.

5.3 Wiring Diagram and Connection Order

Connect the system in the following order: Battery → Load → PV array. Disconnect in the reverse order.

Wiring diagram for EPEVER MPPT Solar Charge Controller
Figure 5.2: Schematic Wiring Diagram for Battery Mode. Connect order: 1 (Battery) -> 2 (DC Load) -> 3 (PV Panel) -> 4 (Inverter, optional). Disconnect order: 4 -> 3 -> 2 -> 1.

CAUTION:

  • Do not connect the circuit breaker or fast-acting fuse during wiring. Ensure correct electrode polarity.
  • A fast-acting fuse (1.25 to 2 times the controller's rated current) must be installed on the battery side, no more than 150 mm from the battery.
  • If an inverter is connected, connect it directly to the battery, not to the load side of the controller.

5.4 Grounding

Tracer-AN G3/Tracer-AN G3 BLE series are common-negative controllers. Negative terminals of the PV array, battery, and load can be grounded simultaneously, or any negative terminal can be grounded. The grounding terminal on its shell must be grounded to shield electromagnetic interference and prevent electric shock.

CAUTION:

It is recommended to use a common-negative controller for common-negative systems (e.g., RV systems). The controller may be damaged if a common-positive controller is used and the positive electrode is grounded in a common-negative system.

5.5 Connect Accessories

Connect the remote temperature sensor cable to the RTS interface and place the other end close to the battery.

CAUTION:

If the remote temperature sensor is not connected or damaged, the controller will charge/discharge the battery at the default 25°C (no temperature compensation).

For RS485 communication, an RS485 communication isolator is recommended before connecting due to the internal circuit having no isolation design.

5.6 Power On the Controller

Connect the battery fast-acting fuse to power the controller. Check the battery indicator status (should be lit green for normal operation). Then connect the fast-acting fuse and circuit breaker of the load and PV array. The system will then operate in preprogrammed mode.

CAUTION:

If the controller is not operating properly or the battery indicator shows an abnormality, refer to the Troubleshooting section.

6. Operating Instructions

6.1 LCD Display and Buttons

The display screen is best viewed when the angle between the user's horizontal sight and the screen is within 90°.

ModeNote
Load ON/OFFTurn load On/Off via the ENTER button in manual load mode.
Clear faultPress the ENTER button.
Browsing modePress the SELECT button to cycle through interfaces.
Setting modePress and hold ENTER for 5s. Use SELECT to set parameters, ENTER to confirm. Exits automatically after 10s of no operation.

6.2 Interface Status Description

NameIconStatus
PV array(Sun icon)Day
(Moon icon)Night
(No charge icon)No charge
(Charging icon)Charging
PV(PV icon)PV array's voltage, current, and generated energy
Battery(Battery icon)Battery capacity, In charging
BATT.(Battery icon)Battery Voltage, Current, Temperature
BATT. TYPE(Battery type icon)Battery type
Load(Load ON icon)Load ON
(Load OFF icon)Load OFF
LOAD(Load icon)Current/Consumed energy/Load mode

6.3 Setting Parameters

Clear Generated Energy: Press and hold ENTER for 5s under the PV-generated energy interface until the value flashes, then press ENTER again to clear.

Switch Battery Temperature Unit: Press and hold the button for 5s under the battery temperature interface.

Battery Type Setting:

  1. Press SELECT to jump to the battery voltage interface.
  2. Press and hold ENTER until the battery-type interface flashes.
  3. Press SELECT to change the battery type (Sealed, Gel, Flooded, LiFePO4, Li(NiCoMn)O2, User).
  4. Press ENTER to confirm.

For "User" battery type, voltage parameters can be set via PC software, APP, or MT52 remote meter.

Connection of EPEVER MPPT Solar Charge Controller to external WiFi 2.4G adapter
Figure 6.1: Connecting to an external WiFi 2.4G adapter for APP control.
Connection of EPEVER MPPT Solar Charge Controller to external Bluetooth adapter
Figure 6.2: Connecting to an external Bluetooth adapter for APP control.
EPEVER MPPT Solar Charge Controller with built-in Bluetooth adapter
Figure 6.3: EPEVER Tracer-AN G3 BLE series with built-in Bluetooth for APP control.
Connection of EPEVER MPPT Solar Charge Controller to MT52 remote meter
Figure 6.4: Connecting to the MT52 remote meter for parameter setting.

6.4 Load Modes

To set load modes:

  1. Press SELECT to jump to the load type interface.
  2. Press and hold ENTER until the load type interface flashes.
  3. Press SELECT to modify the load type.
  4. Press ENTER to confirm.

Available load modes include Light ON/OFF, various timed modes (since sunset/before sunrise), Test mode, and Manual mode (Default load ON).

CAUTION:

When selecting Light ON/OFF, Test mode, or Manual mode, only Timer 1 can be set; Timer 2 is disabled.

6.5 Maximum Power Point Tracking (MPPT) Technology

The controller utilizes advanced MPPT technology to continuously compare and adjust operating points to locate the PV array's maximum power point, ensuring maximum energy harvest. This process is fully automatic. MPPT controllers can increase energy utilization by 10%-30% compared to PWM charging methods.

The system's conversion efficiency is crucial. The greater the difference between the PV array's maximum power point voltage (VMpp) and the battery voltage (VBat), the more important the controller's conversion efficiency becomes.

6.6 Battery Charging Stages

The controller employs a three-stage charging algorithm to prolong battery lifespan:

  • Bulk Charging: Constant current mode, delivering maximum current until battery voltage reaches the constant voltage set point.
  • Constant Charging: MPPT charging stops, and current gradually drops. Includes Equalize Charging (on the 28th of each month) and Boost Charging (default 2 hours).
  • Float Charging: Battery voltage is reduced to a preset float charging voltage. Loads can draw power from the solar panel. If loads exceed solar array power, the controller exits float charging and re-enters bulk charging when battery voltage drops below the boost voltage reconnect voltage.

WARNING (Equalize Charging):

Equalizing flooded batteries produces explosive gases; ensure good ventilation. Equipment damage may occur if DC loads cannot handle increased battery voltage. Over-charging can damage battery plates. Review battery-specific requirements carefully.

7. Maintenance

Perform the following inspections and maintenance tasks at least twice yearly for optimal performance:

  • Ensure no obstructions to airflow around the controller. Clean any dirt or fragments from the radiator.
  • Check all exposed wires for insulation damage (sun exposure, wear, dryness, pests). Repair or replace as needed.
  • Verify indicator display consistency with actual operation. Address any troubleshooting or error conditions.
  • Confirm terminals have no corrosion, insulation damage, high temperature signs, or discoloration. Tighten terminal screws to the suggested torque.
  • Clean dirt, nesting insects, and corrosion.
  • Check the lightning arrester's condition. Replace if necessary to prevent damage to the controller and other equipment.

CAUTION:

Risk of electric shock! Ensure power is turned off before performing any maintenance operations.

8. Troubleshooting

FaultsTroubleshooting
PV array open-circuit (when plenty of direct sunlight)Confirm PV array connection is correct and tight.
Battery voltage is lower than 8V (wire connection correct, controller not working)Check battery voltage (at least 8V needed to activate controller).
Battery over voltage (battery frame blink)Check if battery voltage is higher than OVD (over voltage disconnect voltage) and disconnect PV array.
Battery over discharged (battery frame blink)When battery voltage restores to or above LVR (low voltage reconnect voltage), load will recover. Use other ways to recharge battery.
Battery overheating (battery frame blink)Controller resumes when temperature declines below 55°C.
Overload (load off, load and fault icon blink)Reduce number of electric devices. Restart controller or press button to clear faults.
Load short-circuit (load off, load and fault icon blink)Check load connections carefully, clear fault. Restart controller or press button to clear faults.

Note on Overload/Short-circuit: If load current exceeds rated value, the controller will automatically turn off loads after a delay and attempt to resume multiple times. To restart immediately, press the Load button or restart the controller.

Protection Features:

Protection features of the EPEVER MPPT Solar Charge Controller
Figure 8.1: Visual representation of the controller's protection features.
  • PV Over Current: Controller limits charging to its rated current/power.
  • PV Short-circuit: Controller is not damaged if PV array is short-circuited when not charging. WARNING: Do not short-circuit PV array during charging.
  • PV Reverse Polarity: Controller may resume work after correcting mis-wiring. CAUTION: If PV array is reversed and actual power is 1.5 times rated, controller may be damaged.
  • Night Reverse Charging: Prevents battery discharge to PV module at night.
  • Battery Reverse Protection: Correct wire connection to resume work. WARNING: Controller damaged if PV connection is correct but battery is reversed.
  • Battery Over Voltage Protection: PV array stops charging when battery reaches over voltage disconnect voltage.
  • Battery Over-discharging Protection: Battery discharging stops when voltage is below low voltage disconnect voltage.
  • Battery Overheating Protection: Controller stops working if internal temperature exceeds 65°C, resumes below 55°C. Charging power reduces automatically if internal temperature reaches 81°C.
  • Lithium Battery Low Temperature Protection: Stops charging/discharging if temperature is below LTPT (default 0°C).
  • Load Short Circuit: Controller cuts off output, attempts to resume five times.
  • Overload Protection: Controller cuts off output if load current exceeds 1.05 times rating, attempts to resume five times.
  • TVS High Voltage Transients Protection: Internal circuitry protects against high-voltage surge pulses. External surge arrester recommended for lightning-prone areas.

9. Specifications

9.1 Electrical Parameters (Tracer4210AN G3/G3 BLE)

ParameterValue
Battery Rated Voltage12/24VDC Auto-recognition
Rated Charging Current40A
Rated Discharge Current40A
Controller Work Voltage Range8~31V
PV Maximum Open-circuit Voltage100V (92V at 25°C)
MPPT Voltage Range(Battery voltage +2V)~72V
Rated Charging Power520W/12V, 1040W/24V
Static Losses<8mA(12V), <5mA(24V)
Discharge-circuit Voltage Drop≤0.23V
Temperature Compensation-3mV/°C/2V (Default)
Grounding TypeCommon negative
RS485 Port5VDC/200mA(RJ45)
LCD Backlight TimeDefault: 60S, Range: 0~999S (0 seconds: backlight ON)

Note: When a lithium battery is used, the system voltage isn't automatically identified. Temperature compensation coefficient is 0 and cannot be changed for lithium batteries.

9.2 Environmental Parameters

ParameterValue
Work Temperature Range-25°C~+45°C (100% loads working)
Storage Temperature Range-20°C~+70°C
Relative Humidity< 95% (N.C.)
EnclosureIP30

9.3 Mechanical Parameters (Tracer4210AN G3/G3 BLE)

ParameterValue
Dimension (L x W x H)252x180x63mm
Mounting Size (L x W)204x171mm
Mounting Hole SizeΦ5mm
Terminal6AWG (16mm²)
Recommended Wire Size6AWG (16mm²)
Net Weight1.65kg

10. User Tips

  • Remote Monitoring: For easier monitoring and parameter adjustment, consider using the MT52 remote control panel or a Bluetooth/WiFi module with the EPEVER app. This can be more convenient than using the controller's built-in display.
  • Automatic Voltage Detection: The controller automatically detects 12V or 24V battery setups, simplifying initial configuration.
  • High PV Input: The controller supports PV array open-circuit voltage up to 100V, allowing for flexible solar panel configurations in series.
  • Lithium Battery Settings: When using lithium batteries, remember that the system voltage is not automatically identified, and temperature compensation is fixed at 0°C. Ensure you manually set the correct battery type and parameters via the app, PC software, or MT52.
  • Connectivity Issues: If you encounter difficulties connecting the Wi-Fi or Bluetooth module to the cloud meter or app, consult the detailed instructions in the EPEVER app manual or seek support.
  • Charging Current Limit: The controller limits the charging current to its rated value (e.g., 40A for Tracer4210ANG3). Ensure your battery's maximum charge rate is compatible with this limit to prevent issues.

11. Warranty and Support

For detailed warranty information, including terms, conditions, and duration, please refer to the complete User Manual PDF provided by EPEVER. The PDF also contains comprehensive information regarding product support and service.

You can view the official user manual PDF here.

For technical support or inquiries, please contact EPEVER customer service or your local distributor.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.