1. General Information
The EPEVER XTRA-N G3 and XTRA-N G3 BLE series controllers are advanced Maximum Power Point Tracking (MPPT) solar charge controllers designed for efficient solar energy management. These controllers feature a new design concept, with XTRA-N G3 BLE models including a built-in Bluetooth module for convenient parameter reading and modification via a mobile application.
The controllers utilize an advanced MPPT control algorithm to maximize power point tracking speed and efficiency, ensuring optimal energy harvesting under various conditions. They support independent voltage regulation, allowing direct connection to loads even without a battery. Compatibility with various battery types, including lithium batteries, is a key feature. A low self-consumption design helps reduce static power consumption and extends system standby time.
Key features include charging power/current limits, automatic charging power reduction under high temperatures for system stability, IP33 ingress protection, and an isolated RS485 communication port. The three-stage charging mode effectively prolongs battery lifespan. Comprehensive electronic protections, such as overcharge, over-discharge, and PV & battery reverse polarity, enhance system reliability and durability. These controllers are suitable for RVs, household systems, and monitoring applications.
Product Overview
Key Features
- High quality and low failure rate components (ST or IR) for extended service life.
- Advanced MPPT technology with ultra-fast tracking speed (up to 99.5% efficiency).
- Maximum DC/DC transfer efficiency up to 98.5%; full load efficiency up to 97.2%.
- Advanced MPPT control algorithm to minimize power loss and tracking time.
- Accurate recognition and tracking of multi-peak maximum power points.
- Wider MPP running voltage to optimize PV utilization.
- Support for multiple battery types, including lithium batteries.
- Stable self-activation function for lithium batteries.
- Battery temperature compensation.
- Charging power and current limits to prevent overcharging.
- Real-time energy statistics function.
- Automatic charging power reduction for over-temperature conditions.
- Built-in Bluetooth for XTRA-N G3 BLE models to adjust settings via EPEVER APP.
- RS485 communication interface with optional 4G or Wi-Fi modules for remote monitoring.
- Parameters configurable via PC software, APP, or remote meter.
- Constant voltage output function.
- Comprehensive electronic protections.
- Multiple load work modes (Time Control, Light ON/OFF, Manual Mode).
- Dustproof and waterproof design with IP33 enclosure.
- Low self-consumption, lower than 10mA.
- Operation at full load without charging power reduction within the working temperature range.
Product Video Overview
2. Important Safety Instructions
Please keep this manual for future review. This manual contains all safety, installation, and operation instructions for the XTRA-N G3 or XTRA-N G3 BLE series Maximum Power Point Tracking (MPPT) controller.
2.1 Safety Instructions for Installation
- Read all instructions and warnings carefully in the manual before installation.
- No user-serviceable components exist inside the controller. DO NOT disassemble or attempt to repair the controller.
- Mount the controller indoors. Avoid exposure to components and do not allow water to enter the controller.
- Install the controller in a well-ventilated place. The controller's heat sink may become very hot during operation.
- Suggest installing appropriate external fast-acting fuses/breakers.
- Disconnect all PV array connections and the fast-acting fuses/breakers before controller installation and adjustment.
- Power connections must remain tight to avoid excessive heating from a loose connection.
WARNING:
Do not install the controller in humid, high salt spray, corrosion, greasy, flammable, explosive, dust accumulative, or other severe environments.
2.2 Other Safety Instructions (FCC Compliance)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
3. Installation
3.1 Attentions
- Be very careful when installing batteries, especially flooded lead-acid batteries. Wear eye protection and have fresh water available to wash any contact with battery acid.
- Keep the battery away from any metal objects to prevent short circuits.
- Ensure good ventilation as explosive battery gases may be released during charging.
- Never install the controller in a sealed enclosure with flooded batteries, as fumes can corrode circuits.
- Ensure tight power connections to avoid excessive heating and potential fire hazards. Use cable clamps to secure cables.
- The controller supports lead-acid and lithium batteries within its control scope.
- Battery connections can be made to a single battery or a bank of batteries.
- Select system cables according to 5A/mm² current density or less, following Article 690 of the National Electrical Code, NFPA 70.
- The grounding wire size should not be less than 4mm².
- The torque for tightening wiring screws should be at least 1.2N.m.
3.2 PV Array Requirements
The controller is compatible with various PV modules. The series number of PV modules can be calculated based on the open-circuit voltage (Voc) and maximum power point voltage (Vmpp) of the MPPT controller. Refer to the tables in the full PDF manual for detailed PV array configuration based on system voltage and controller model.
NOTE: All PV modules in a given array are assumed to be identical. Isc = short circuit current (amps), Voc = open circuit voltage.
3.3 Wire Size
The wiring and installation methods must conform to national and local electrical code requirements. The PV array output varies with module size, connection method, and sunlight angle. The PV array's short circuit current (ISC) is used to calculate the minimum PV wire size. Refer to the value of Isc in the PV module specification.
The battery and load wire size must conform to the rated current. Refer to the tables in the full PDF manual for detailed wire sizing based on controller model and current ratings.
CAUTION:
The wire size is only for reference. For long distances between the PV array, controller, and battery, larger wires may be used to reduce voltage drop and improve performance. The recommended battery wire is selected when the battery terminals are not connected to any additional inverter.
3.4 Mounting
WARNING:
Risk of explosion! Never install the controller in a sealed enclosure with flooded batteries! Do not install in a confined area where battery gas can accumulate.
Risk of electric shock! When wiring solar modules, the PV array can produce a high open-circuit voltage. Disconnect the breaker before wiring and be careful.
CAUTION:
The controller requires at least 150mm of clearance above and below for proper airflow. Ventilation is highly recommended if mounted in an enclosure.
Step 1: Determine Installation Location and Heat-Dissipation Space
The controller should be installed in a location with sufficient airflow through its radiators. Maintain a minimum clearance of 150 mm from the upper and lower edges to ensure natural thermal convection.
CAUTION:
If the controller is installed in an enclosed box, ensure reliable heat dissipation through the box.
Step 2: Wiring Connection Order
Connect the system in the order of battery → load → PV array. Disconnect in the reverse order: PV array → load → battery.
Battery Mode Wiring Diagram:
A fast-acting fuse (1.25 to 2 times the rated current of the controller) must be installed on the battery side, no more than 150 mm from the battery.
No-Battery Mode Wiring Diagram:
When no battery is present, the XTRA-N G3/XTRA-N G3 BLE series can be directly connected to an inverter. The inverter must be connected to the battery terminals of the controller. Ensure PV input power is greater than (load output power / inverter conversion efficiency / controller conversion efficiency) for high-frequency inverters, and greater than (load output power / inverter conversion efficiency / controller conversion efficiency / 2) for power frequency inverters.
CAUTION:
When wiring, do not connect the circuit breaker or fast-acting fuse until all connections are secure. Ensure correct electrode polarity.
If the controller is used in an area with frequent lightning strikes, install an external surge arrester.
If an inverter is connected, it must be connected directly to the battery, not to the load side of the controller.
Step 3: Grounding
XTRA-N G3/XTRA-N G3 BLE series are common-negative controllers. All negative terminals can be grounded simultaneously, or any one can be grounded. The grounding terminal on the shell must be grounded to shield electromagnetic interference and prevent electric shock.
CAUTION:
A common-negative controller is recommended for common-negative systems (e.g., motorhomes). The controller may be damaged if a common-positive controller is used and the positive electrode is grounded in a common-negative system.
Step 4: Connect Accessories
Connect the remote temperature sensor cable to the controller's interface and place the other end close to the battery. If not connected, the default battery charging/discharging temperature setting is 25°C without compensation.
For RS485 communication accessories, refer to the